INCH-POUND
MIL-PRF-32675A
13 February 2023
SUPERSEDING
MIL-PRF-32675
12 January 2021
PERFORMANCE SPECIFICATION
ARMY STANDARD FAMILY OF RIGID WALL SHELTERS
EXPANDABLE/NON-EXPANDABLE VARIANT
This specification is approved for use by all Departments and Agencies of the
Department of Defense.
AMSC N/A FSC: 5411
DISTRIBUTION STATEMENT A: Approved for public release; distribution is unlimited.
Comments, suggestions, or questions on this document should be addressed to: Product Manager
Force Sustainment Systems, ATTN: Ryan Devine, U.S. Army Natick Soldier Systems Center,
Natick, MA 01760. You may also email [email protected]. Since contact information
can change, you may want to verify the currency of this address using the ASSIST Online database
at https://assist.dla.mil.
Source: https://assist.dla.mil -- Downloaded: 2023-03-15T01:03Z
Check the source to verify that this is the current version before use.
MIL-PRF-32675A
2
1. SCOPE
1.1. Scope. This specification covers the design, performance, environmental, and safety
requirements of shelters contained within the Army Standard Family of Rigid Wall Shelters
(ASF-RWS) Expandable/Non-Expandable variant. The ASF-RWS includes two other variants,
but this specification pertains only to the Expandable/Non-Expandable variant.
1.2. Classification. The Expandable/Non-Expandable variant of the ASF-RWS is comprised of
several sizes, types, and classes of shelters, each heretofore referred to as “the shelter”.
1.2.1. Sizes. The sizes of shelters within the Expandable/Non-Expandable variant are as follows:
Size I – 20-foot long (commonly known as a 20-foot ISO)
Size II – 10-foot long (commonly known as a BICON)
Size III – 6.6-foot long (commonly known as a TRICON)
1.2.2. Types. The types of shelters within the Expandable/Non-Expandable variant are as
follows:
Type A – Non-expandable
Type B – One-side expandable
Type C – Two-side expandable
1.2.3. Classes. Unique classes of shelters within the Expandable/Non-Expandable variant are as
follows (shelters not designated with a class can be assumed to be of standard design and
performance):
Class B – Basic
Class C – Chemical and biological (CB) hardened class
Class E – Electromagnetic interference (EMI) shielded class
Class H – Heavy class (and hook bar equipped)
Class M – Medical class
2. APPLICABLE DOCUMENTS
2.1. General. The documents listed in this section are specified in sections 3 and 4 of this
specification. This section does not include documents in other sections of this specification or
recommended for additional information or as examples. While every effort has been made to
Source: https://assist.dla.mil -- Downloaded: 2023-03-15T01:03Z
Check the source to verify that this is the current version before use.
MIL-PRF-32675A
3
ensure the completeness of this list, document users are cautioned that they must meet all
specified requirements documents cited in sections 3 and 4 of this specification, whether or not
they are listed.
2.2. Government documents. The following drawings, specifications, standards, and other
publications form a part of this document to the extent specified herein. Unless otherwise
specified, the issues of these documents are those cited in the solicitation or contract.
5-4-9755 – Natick Research, Development and Engineering Center (NRDEC)
Drawing, Tent, Extendable, Modular, Personnel (TEMPER),
Interface Control Drawing
(Copies of this document are available through Product Manager Force Sustainment Systems,
ATTN: SFAE-CSS-E2-F, U.S. Army Natick Soldier Systems Center, Natick, MA 01760.)
ECBC-TR-849 – Test Standard for Wind-Driven Challenge Testing of Pressurized
Collective Protection Systems
(Copies of this document are available through Director, Edgewood Chemical Biological Center,
ATTN: RDCB-DRF-T, Aberdeen Proving Ground, MD 21010.)
FM 3-11.5 – CBRN Decontamination – Multiservice Tactics, Techniques, and
Procedures for Chemical, Biological, Radiological, and Nuclear
Decontamination
(Copies of this document are available online at https://www.us.army.mil or
https://www.train.army.mil.)
MIL-DTL-22992 – Detail Specification, Connectors, Plugs and Receptacles,
Electrical, Waterproof, Quick Disconnect, Heavy Duty Type
MIL-DTL-53039 – Detail Specification, Coating, Aliphatic Polyurethane, Single
Component, Chemical Agent Resistant
MIL-STD-129 – Military Marking for Shipment and Storage
MIL-STD-130 – Identification Marking of U.S. Military Property
MIL-STD-209 – Interface Standard for Lifting and Tiedown Provisions
MIL-STD-810 – Test Method Standard for Environmental Engineering
Considerations and Laboratory Tests
MIL-STD-913 – Design Criteria Standard, Requirements for the Certification of
Sling Loaded Military Equipment for External Transportation by
Department of Defense Helicopters
Source: https://assist.dla.mil -- Downloaded: 2023-03-15T01:03Z
Check the source to verify that this is the current version before use.
MIL-PRF-32675A
4
MIL-STD-1366 – Interface Standard for Transportability Criteria
MIL-STD-1408 – Interface Standard, Air Conditioners, Improved Family of Military
Air Conditioners, General Application Characteristics
MIL-STD-1472 – Design Criteria Standard Human Engineering
MIL-T-704 – Military Specification, Treatment and Painting of Materiel
A-A-59166 – Coating Compound, Nonslip (for Walkways)
STANAG 2413 – Demountable Load Carrying Platforms (DLCP/Flatracks)
(Copies of these documents are available online at https://quicksearch.dla.mil.)
2.3. Non-government documents. The following documents form a part of this document to the
extent specified herein. Unless otherwise specified, the issues of these documents are those cited
in the solicitation or contract.
ASTM E90 – Standard Test Method for Laboratory Measurement of Airborne
Sound Transmission Loss of Building Partitions and Elements
ASTM E413 – Classification for Rating Sound Insulation
ASTM E1851 – Standard Test Method for Electromagnetic Shielding Effectiveness
of Durable Rigid Wall Relocatable Structures
(Copies of these documents are available online at https://www.astm.org.)
ISO 668 – Series 1 Freight Containers – Classification, Dimensions, and
Ratings
ISO 1496-1 – Series 1 Freight Containers – Specification and Testing – Part 1:
General Cargo Containers for General Purposes
ISO 6346 – Freight Containers – Coding, Identification, and Marking
(Copies of these documents are available online at https://www.iso.org.)
NFPA 70 – National Electrical Code
(Copies of this document are available online at https://www.nfpa.org.)
SAE-AMS-STD-595 – Colors Used in Government Procurement
Source: https://assist.dla.mil -- Downloaded: 2023-03-15T01:03Z
Check the source to verify that this is the current version before use.
MIL-PRF-32675A
5
(Copies of this document are available online at https://www.sae.org.)
2.4. Order of precedence. Unless otherwise noted herein or in the contract, in the event of a
conflict between the text of this document and the references cited herein, the text of this
document takes precedence. Nothing in this document, however, supersedes applicable laws and
regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1. First article. When specified (see section 6.2), the shelter shall be subjected to first article
inspection in accordance with section 4.2.
3.2. Materials. Materials and construction methods are the choice and responsibility of the
contractor and shall be capable of meeting all of the requirements specified herein. Materials
and design shall be such to minimize the effects of galvanic corrosion.
3.2.1. Recycled, recovered, environmentally preferable, or biobased materials. Recycled,
recovered, environmentally preferable, or biobased materials should be used to the maximum
extent possible, provided that the material meets or exceeds the operation and maintenance
requirements, and promotes economically advantageous life cycle costs.
3.3. Workmanship. The shelter shall be in accordance with the quality of product established by
this performance specification. Utmost care shall be taken during fabrication to ensure quality
workmanship and safety of the service person using the item. Manufacturing practices shall be
capable of consistently yielding product that conforms to all requirements in this specification
and any internal specifications. Continual improvement shall also be a constant focus of the
manufacturing practices. Materials shall be produced and integrated to extend durability and
provide consistency of appearance throughout the product’s life. All components to be
assembled shall be thoroughly cleaned of all foreign matter. In any case of material, process, or
equipment change desired to be made by the contractor, the written consent of the Government
shall be obtained before making the change. Additional testing may be required prior to
implementation of the change to verify product performance.
3.4. Design requirements. The shelter shall be of suitable form, fit, and function for a wide range
of military and non-military applications and shall be designed for maximum sustainability. As
such, the shelter shall comply with the following design requirements.
3.4.1. Transport mode exterior dimensions. The exterior dimensions of the shelter in its closed,
ready-for-transport configuration, heretofore referred to as “transport mode”, shall be in
accordance with ISO 1496-1, and by reference ISO 668. In the case of a Size I shelter, the
exterior dimensions of the shelter shall be in accordance with the requirements for the 1C ISO
designation. In the case of a Size II shelter, the exterior dimensions of two such shelters coupled
together end-to-end shall be in accordance with the requirements for the 1C ISO designation. In
the case of a Size III shelter, the exterior dimensions of three such shelters coupled together end-
to-end shall be in accordance with the requirements for the 1C ISO designation.
Source: https://assist.dla.mil -- Downloaded: 2023-03-15T01:03Z
Check the source to verify that this is the current version before use.
剩余27页未读,继续阅读
资源评论
phyit
- 粉丝: 7639
- 资源: 2773
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
- IMG_20240517_211955.jpg
- 多语言实现的520爱心表白特效.zip
- Excel模板微信小程序学习心得和案例1.docx
- Modbus Poll version 10.9.0 Build 2194
- Modbus Slave version 9.3.2 Build 2156
- 响应式web前段开发程序源代码
- Excel模板大学实验课程改革与学生创新能力培养学生课程实验.doc
- 使用文件流操作文本文件是什么以及学习了解使用文件流操作文本文件的意义是什么
- SNP指纹图谱软件SNPT ,通过高通量测序获得的SNP,用最少的SNP数据区分尽量多的样品
- windowsBat脚本备份mysql数据库
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功