没有合适的资源?快使用搜索试试~ 我知道了~
TI-SN75LBC031.pdf
0 下载量 61 浏览量
2022-12-16
23:22:55
上传
评论 4
收藏 967KB PDF 举报
温馨提示
试读
18页
Lin收发器
资源推荐
资源详情
资源评论
SN65LBC031, SN65LBC031Q, SN75LBC031
HIGH-SPEED CONTROLLER AREA NETWORK (CAN) TRANSCEIVERS
SLRS048A – MAY 1998 – REVISED APRIL 2000
1
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
D
SN75LBC031 Meets Standard ISO/DIS
11898 (up to 500 k Baud)
D
Driver Output Capability at 50 mA
D
Wide Positive and Negative Input/output
Bus Voltage Range
D
Bus Outputs Short-Circuit-Protected to
Battery Voltage and Ground
D
Thermal Shutdown
D
Available in Q-Temp Automotive
– HighRel Automotive Applications
– Configuration Control/Print Support
– Qualification to Automotive Standards
description
The SN75LBC031 is a CAN transceiver used as
an interface between a CAN controller and the
physical bus for high speed applications of up to
500 kBaud. The device provides transmit
capability to the differential bus and differential
receive capability to the controller. The transmitter
outputs (CANH and CANL), feature internal
transition regulation to provide controlled
symmetry resulting in low EMI emissions. Both
transmitter outputs are fully protected against battery short circuits and electrical transients that can occur on
the bus lines. In the event of excessive device power dissipation the output drivers are disabled by the thermal
shutdown circuitry at a junction temperature of approximately 160°C. The inclusion of an internal pullup resistor
on the transmitter input ensures a defined output during power up and protocol controller reset. For normal
operation at 500 kBaud the ASC terminal is open or tied to GND. For slower speed operation at 125 kBaud the
bus output transition times can be increased to reduce EMI by connecting the ASC terminal to V
CC
. The receiver
includes an integrated filter that suppresses the signal into pulses less than 30 ns wide.
The SN75LBC031 is characterized for operation from –40°C to 85°C. The SN65LBC031 is characterized for
operation from –40°C to 125°C. The SN65LBC031Q is characterized for operation over the automotive
temperature range of –40°C to 125°C.
Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of
Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.
Copyright 2000, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
FUNCTION TABLE
TX
CANH
BUS STATE
CANL RX
L
High or floating
L = low, H = high
H
Floating
L
Floating
L
H
Dominant
Recessive
1
2
3
4
8
7
6
5
TX
GND
V
CC
RX
ASC
CANH
CANL
REF
D PACKAGE
(TOP VIEW)
TERMINAL
TERMINAL FUNCTIONS
DESCRIPTION
TX
GND
RX
V
CC
REF
CANL
CANH
ASC
Transmitter input
Adjustable slope control
Ground
Supply voltage
Receiver output
Reference output
Low side bus output driver
High side bus output driver
SN65LBC031, SN65LBC031Q, SN75LBC031
HIGH-SPEED CONTROLLER AREA NETWORK (CAN) TRANSCEIVERS
SLRS048A – MAY 1998 – REVISED APRIL 2000
2
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
logic diagram
ASC
CANH
2R
2R
CANL
GND
V
CC
RX
REF
TX
RR
R2
R3
R1
R1
RR
SN65LBC031, SN65LBC031Q, SN75LBC031
HIGH-SPEED CONTROLLER AREA NETWORK (CAN) TRANSCEIVERS
SLRS048A – MAY 1998 – REVISED APRIL 2000
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Logic supply voltage, V
CC
(see Note 1) 7 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Bus terminal voltage –5 V to 20 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input current at TX and ASC terminal, I
I
±10 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage at TX
and ASC terminal, V
I
2 × V
CC
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating free-air temperature range, T
A
: SN65LBC031, SN65LBC031Q –40°C to125°C. . . . . . . . . . . . . . .
SN75LBC031 –40°C to 85°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Operating juncation range, T
J
–40°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Continuous total power dissipation at (or below) 25°C free-air temperature See Dissipation Rating Table. .
Storage temperature range, T
stg
–65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Case temperature for 10 sec T
C
, D package 260°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTE 1: All voltage values, except differential bus voltage, are measured with respect to GND.
DISSIPATION RATING TABLE
PACKAGE
T
A
≤ 25°C
POWER RATING
OPERATING FACTOR
ABOVE T
C
= 25°C
T
C
= 125°C
POWER RATING
D 725 mW 5.8 mW/°C 145 mW
1200
800
400
0
25 45 65 85
– Maximum Continuous Dissipation – mW
DISSIPATION DERATING CURVE
vs
FREE-AIR TEMPERATURE
105 125
1000
600
200
P
D
T
A
– Free-Air Temperature – °C
T
C
= 25°C
35 55 75 95 115
D = 5.8 mW/°C
P = 8.8 mW/°C
Figure 1
SN65LBC031, SN65LBC031Q, SN75LBC031
HIGH-SPEED CONTROLLER AREA NETWORK (CAN) TRANSCEIVERS
SLRS048A – MAY 1998 – REVISED APRIL 2000
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
recommended operating conditions
MIN NOM MAX UNIT
Logic supply voltage, V
CC
4.5 5 5.5 V
Voltage at any bus terminal (separately or common mode), V
I
or V
IC
(see Note 3) –2 7 V
High-level input voltage, V
IH
TX 2 V
CC
V
Low-level input voltage, V
IL
TX 0 0.8 V
High level out
p
ut current I
OH
Transmitter –50 mA
High
-
le
v
el
o
u
tp
u
t
c
u
rrent
,
I
OH
Receiver –400 µA
Low level out
p
ut current I
OL
Transmitter 50
mA
Lo
w-
le
v
el
o
u
tp
u
t
c
u
rrent
,
I
OL
Receiver 1
mA
O
p
erating free air tem
p
erature T
A
SN75LBC031 –40 85
°
C
Operating
free
-
air
temperat
u
re
,
T
A
SN65LBC031, SN65LBC031Q –40 125
°C
NOTES: 2. All voltage values, except differential bus voltage, are measured with respect to the ground terminal.
3. For bus voltages from –5 V to –2 V and 7 V to 20 V the receiver output is stable.
SYMBOL DEFINITION
DATA SHEET PARAMETER
DEFINITION
V
O(CANHR)
CANH bus output voltage (recessive state)
V
O(CANLR)
CANL bus output voltage (recessive state)
V
O(CANHD)
CANH bus output voltage (dominant state)
V
O(CANLD)
CANL bus output voltage (dominant state)
V
O(DIFFR)
Bus differential output voltage (recessive state)
V
O(DIFFD)
Bus differential output voltage (dominant state)
V
I(ASC)
Adjustable slope control input voltage
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
O(REF)
Reference source output voltage I
REF
= ±20 µA 0.45V
CC
0.55V
CC
V
R
O(REF)
Reference source output resistance 5 10 kΩ
I
CC(REC)
Logic supply current, recessive state
See Figure 2 S1 closed
12 20
mA
I
CC(DOM)
Logic supply current, dominant state
See
Fig
u
re
2
,
S1
closed
55 80
mA
剩余17页未读,继续阅读