New Features
ibaAnalyzer v7.3.0
Authors: M. Verschaeve, C. Reinbrecht, T. Seitz
Date: 6th April 2021
iba AG • Königswarterstr. 44 • D-90762 Fürth • Germany • www.iba-ag.com
New Features
ibaAnalyzer 7.3.0
2/19
Table of contents
1 Always query digital signals on raw level from ibaHD-Server ..................................... 3
2 Support for Active Directory in ibaHD-Server ............................................................ 4
3 New Product: ibaAnalyzer-Maps............................................................................... 5
4 New Product: ibaAnalyzer-InCycle ........................................................................... 16
5 Further improvements ............................................................................................ 18
5.1 X1 marker zoom for ActiveX Trendview .......................................................................... 18
5.2 Toggle visibility for all active x view areas ...................................................................... 18
5.3 Use first text channel for export ..................................................................................... 19
ibaAnalyzer v7.3.0
New Features
3/19
1 Always query digital signals on raw level from ibaHD-Server
With this version of ibaAnalyzer a new option “Query digital signals on raw level as non-
equidistant data” has been added to the HD Server query settings. Using this option, it is
possible to always query digital signals as raw data independent on the aggregation layer which
is used for analog values. Especially for long-time queries this makes it possible to correctly
measure duration or to evaluate time stamps of value changes without the usual errors
introduced by the data aggregation on HD-Server.
If this option is enabled, ibaAnalyzer uses a different mechanism to query digital signals from
any ibaHD-Server:
Instead of getting all data of the configured aggregation layer, only signal changes in the raw
data level are detected and one data point is queried for every change of the signal from true to
false and vice versa. The result will be a non-equidistant digital signal.
Note
Most functions in ibaAnalyzer are able to handle non equidistant signals. In some cases there
are differences (e.g. when using XBase()) and you should check your existing analysis if you
enable this option. Please contact iba support if any function does not work as you expect it with
those signals.
Warning
In case the digital signal has too many value changes, this option can cause ibaAnalyzer to
hang. In case of doubt, disable the option, then data are queried from a suitable aggregation
layer resulting in the usual performance of ibaAnalyzer.
New Features
ibaAnalyzer 7.3.0
4/19
2 Support for Active Directory in ibaHD-Server
With version 2.6.0 of ibaHD-Server or later, Active Directory users are supported in the user
management. Starting from this version of ibaAnalyzer, it is possible to use Active Directory
credentials when connecting to ibaHD-Server.
The Active Directory user name should be in the format domain\user. The domain can be the
short name (e.g. iba-ag) or the fully qualified domain name (e.g. iba-ag.local). If the connect fails
with the short name then try the fully qualified domain name. The user part should be the
(legacy) user logon name.
ibaAnalyzer v7.3.0
New Features
5/19
3 New Product: ibaAnalyzer-Maps
The licensed add-on product “ibaAnalyzer-Maps” is included in this release. For details on
prices and usage, please refer to our website and the information provided there.
In order to use ibaAnalyzer-Maps two signals representing longitude and latitude are required.
The values of the signal have to represent degrees in floating point format, i.e. decimal degrees.
Additional minutes and seconds as separate signals are not supported. Expressions can be
used in ibaAnalyzer to create suitable signals.
A new maps view can be opened by clicking the corresponding icon in the main toolbar or the
“View” menu.
Note
An active internet connection is necessary to use ibaAnalyzer-Maps. If ibaAnalyzer cannot
establish a connection, a suitable message is shown. If no valid license is present, the view can
be opened but is non-functional.