3
Power Choke
7. Specifications
Part Number
LO
inductance
(uH)
@(0A)
Rdc (mΩ)
Heat Rating Current
DC Amps Idc (A)
Saturation Current
DC Amps Isat (A)
Typical Maximun Typical Typical
0.5 2.8 3.4 20 21
1.1 4.6 5.5 15.3 19
1.5 8 10 11.5 13
2.2 9.8 12 11 11
3.3 12.5 16 10 10
4.7 18.4 24 6.7 8
5.6 21 29 6.3 8
6.8 29 33 6 7
8.2 34 39 5 5.5
10 42.5 45 4.1 5
12 46.3 53 4 5
15 57.3 60 3.6 4.3
*: If you require another part number please contact with PREJECTION Industrial.
Note 1:All test data is referenced to 25℃ ambient.
Note 2:Idc:DC current (A) that will cause an approximate ΔT of 40℃
Note 3:Isat:DC current (A) that will cause LO to drop approximately 20%
Note 4:Operating Temperature Range - 55℃ to + 125℃
Note5:The part temperature (ambient + temp rise) should not exceed 125℃ under worse case operating
conditions. circuit design , component placement , PWB trace size and thickness , airflow and other
cooling provision all affect the part temperature. part temperature should be verified in
the end application.
DOCUMENT
REVISION
PAGE
:
: 01