– 3 – EN 60204-1:2006
CONTENTS
INTRODUCTION ..................................................................................................................7
1
Scope ............................................................................................................................9
2 Normative references ...................................................................................................10
3 Definitions....................................................................................................................12
4 General requirements...................................................................................................19
4.1 General considerations........................................................................................19
4.2 Selection of equipment ........................................................................................20
4.3 Electrical supply ..................................................................................................21
4.4 Physical environment and operating conditions ....................................................22
4.5 Transportation and storage..................................................................................24
4.6 Provisions for handling ........................................................................................24
4.7 Installation ..........................................................................................................24
5 Incoming supply conductor terminations and devices for disconnecting and
switching off .................................................................................................................24
5.1 Incoming supply conductor terminations ..............................................................24
5.2 Terminal for connection to the external protective earthing system .......................25
5.3 Supply disconnecting (isolating) device................................................................25
5.4 Devices for switching off for prevention of unexpected start-up ............................28
5.5 Devices for disconnecting electrical equipment ....................................................28
5.6 Protection against unauthorized, inadvertent and/or mistaken connection.............29
6 Protection against electric shock ..................................................................................29
6.1 General...............................................................................................................29
6.2 Protection against direct contact..........................................................................29
6.3 Protection against indirect contact .......................................................................32
6.4 Protection by the use of PELV .............................................................................33
7 Protection of equipment................................................................................................34
7.1 General...............................................................................................................34
7.2 Overcurrent protection.........................................................................................34
7.3 Protection of motors against overheating .............................................................37
7.4 Abnormal temperature protection.........................................................................38
7.5 Protection against supply interruption or voltage reduction and subsequent
restoration...........................................................................................................38
7.6 Motor overspeed protection .................................................................................39
7.7 Earth fault/residual current protection ..................................................................39
7.8 Phase sequence protection..................................................................................39
7.9 Protection against overvoltages due to lightning and to switching surges..............39
8 Equipotential bonding ...................................................................................................39
8.1 General...............................................................................................................39
8.2 Protective bonding circuit ....................................................................................42
8.3 Functional bonding ..............................................................................................45
8.4 Measures to limit the effects of high leakage current ............................................45
Licensed Copy: Wang Wenwen, TUV Rheinland (Shanghai), Thu Aug 31 11:10:27 BST 2006, Uncontrolled Copy, (c) BSI