没有合适的资源?快使用搜索试试~ 我知道了~
109739678_TIAV15_OpennessModularMachine_DOC_v11_en.pdf
需积分: 5 0 下载量 196 浏览量
2024-04-20
23:41:49
上传
评论
收藏 2.56MB PDF 举报
温馨提示
试读
43页
109739678_TIAV15_OpennessModularMachine_DOC_v11_en.pdf
资源推荐
资源详情
资源评论
Table of Contents
Unrestricted OpennessModularMachine
Entry ID: OpennessModularMachine, V1.1, 05/2018
2
Siemens AG 2018 All rights reserved
Legal information
Use of the application examples
The application examples represent example solutions of automation tasks combined with
multiple components in the form of text, graphics and/or software modules. The application
examples are a cost-free service of Siemens AG and/or a subsidiary company of Siemens AG
("Siemens"). They are not binding and do not claim to be complete or functional with regard to
configuration or equipment. The application examples do not represent customer-specific
solutions, but rather only provide help for typical tasks. You yourself are responsible for the proper
and safe operation of products in compliance with the applicable regulations. You must check the
function of the respective application example and adapt it specifically to your system.
Siemens grants you the non-exclusive, non-sublicensable and non-transferable right of use of the
application examples by professionally trained personnel. Any change to the application examples
is made at your own risk. Transfer to third parties or duplication of the application examples or
extracts thereof is only permitted in combination with your own products. The application
examples do not necessarily undergo the usual tests and quality checks of a paid product, may
contain functional and performance defects and may be subject to errors. You are responsible for
ensuring that the application examples are used in such a way that any defective functions do not
lead to property damage or bodily injury.
Disclaimer of liability
Siemens excludes its liability, irrespective of the legal ground, in particular for the usability,
availability, completeness and freedom from defects of the application examples, as well as
associated notes, configuration data and performance data and any damage caused by these.
This does not apply if Siemens is compulsorily liable, e.g. under product liability law, in cases of
intent, gross negligence, culpable injury to life, body or health, failure to comply with a guarantee,
fraudulent concealment of a defect or culpable breach of essential contractual obligations. The
claims for compensation for the breach of essential contractual obligations are, however, limited
to the foreseeable damage, typical for the type of contract, except in the event of intent or gross
negligence or injury to life, body or health. The above provisions do not imply a change in the
burden of proof to your detriment. You exempt Siemens from any third-party claims that may exist
or arise in this connection, unless Siemens is compulsorily liable by law.
By using the application examples, you agree that Siemens cannot be made liable for any
possible damage beyond the liability provisions described.
Additional information
We reserve the right to make changes to these application examples at any time without prior
notice. If there are any discrepancies between the recommendations provided in these application
examples and other Siemens publications – e.g. catalogs – the contents of the other documents
have priority.
In addition to this, the Siemens terms and conditions of use apply
(https://support.industry.siemens.com).
Security information
Siemens provides products and solutions with industrial security functions that support the secure
operation of plants, systems, machines and networks.
In order to protect plants, systems, machines and networks against cyber threats, it is necessary
to implement – and continuously maintain – a holistic, state-of-the-art industrial security concept.
Siemens’ products and solutions only form one element of such a concept.
Customer is responsible for preventing unauthorized access to its plants, systems, machines and
networks. Systems, machines and components should only be connected to the enterprise
network or the Internet where necessary and with appropriate security measures (e.g. use of
firewalls and network segmentation) in place.
Additionally, Siemens’ guidance on appropriate security measures should be taken into account.
For more information about industrial security, please visit:
https://www.siemens.com/industrialsecurity.
Siemens’ products and solutions undergo continuous development to make them more secure.
Siemens strongly recommends applying product updates as soon as they are available, and
always using the latest product version. Use of product versions that are no longer supported, and
failure to apply latest updates may increase customer’s exposure to cyber threats.
To stay informed about product updates, subscribe to the Siemens Industrial Security RSS feed
at: https://www.siemens.com/industrialsecurity.
Table of Contents
Unrestricted OpennessModularMachine
Entry ID: OpennessModularMachine, V1.1, 05/2018
3
Siemens AG 2018 All rights reserved
Table of Contents
Legal information ......................................................................................................... 2
1 Task ..................................................................................................................... 4
2 Solution............................................................................................................... 5
2.1 Overview............................................................................................... 5
2.2 Hardware and software components ................................................... 7
2.2.1 Validity .................................................................................................. 7
2.2.2 Components used ................................................................................ 7
3 Basics ............................................................................................................... 10
3.1 Basics on TIA Portal Openness ......................................................... 10
3.2 Basics on the "option handling" configuration control ........................ 10
3.3 Basics on "Apache Tomcat" web server ............................................ 11
4 Mode of Operation ........................................................................................... 12
4.1 General overview ............................................................................... 12
4.2 Modular project ................................................................................... 13
4.2.1 Organization block "Main" [OB 1] ....................................................... 14
4.2.2 "Conveyor" [FB 1] function block ........................................................ 15
4.2.3 "Drive" [FB 2] function block ............................................................... 17
4.3 Initial project ....................................................................................... 18
4.3.1 "MainOptionHandling" [OB 125] organization block ........................... 18
4.3.2 "ActDeactDrive" [FB 15] function block .............................................. 19
4.3.3 "PlantConfigData" [DB 7] global data block ....................................... 20
4.3.4 "SpeedAxisData" [DB 114] global data block ..................................... 20
5 Installation and Commissioning .................................................................... 21
5.1 Installing the software (download) ...................................................... 21
5.2 Installation of the "Apache Tomcat" web server optional ................... 22
5.2.1 Installation of the "Apache Tomcat" web server................................. 22
5.2.2 Setting the Windows Firewall ............................................................. 24
5.2.3 Installing the openness web application "WebAppOpenness" ........... 27
5.2.4 Security setting in the "Apache Tomcat" directory ............................. 28
5.3 Creating the configuration file ............................................................ 29
5.4 Installation of the OpennessApplication "TIA Openness Project" ...... 29
5.5 Managing the user rights .................................................................... 32
5.6 Granting access ................................................................................. 33
6 Operating the Application Example ............................................................... 34
6.1 Scenario A .......................................................................................... 35
6.2 Scenario B .......................................................................................... 41
7 Links & Literature ............................................................................................ 43
8 History............................................................................................................... 43
1 Task
Unrestricted OpennessModularMachine
Entry ID: OpennessModularMachine, V1.1, 05/2018
4
Siemens AG 2018 All rights reserved
1 Task
Introduction
TIA Portal Openness V15 is an open interface to TIA Portal V15. With TIA Portal
Openness you can automatize and remote control your engineering tasks in the
TIA Portal Openness with independent scripts or programs.
Overview of the application example
The following figure gives you an overview of the application example. In the right
column the modular system "Conveyor" is supplemented by a "Drive". In the
variants the quantity is supplemented by identical systems.
Figure 1-1
Conveyor Conveyor & Drive
Variant 1
Variant 2
Variant 3
Description of the application example
The aim of the application example is to start the TIA Portal via a remote control and to
configure and generate a STEP 7 project for a modular machine. All variants of the system are
automatized with the same STEP 7 project and without reconfiguration.
2 Solution
Unrestricted OpennessModularMachine
Entry ID: OpennessModularMachine, V1.1, 05/2018
5
Siemens AG 2018 All rights reserved
2 Solution
2.1 Overview
Schematic layout
The diagrammatic representation below shows what components are involved in
the maximum configuration of the solution:
Figure 2-1
TIA
Openness
Project
XML-Files
PG/PC
SINAMICS G120
S7-1500 TP700
PROFINET / IE
ET 200AL
Configuration
The "TIA Openness Project" starts the TIA Portal and opens the initial project. This
project consists of a pre-configured maximum configuration, which includes all
variants of the machine. Depending on variant the "TIA Openness Project"
changes the previously created XML files (program blocks) and imports this in the
project. The optional operator panel visualizes the plant.
Advantages
Remote control of the TIA Portal in order to create projects.
Provision of project data of the TIA Portal for external applications.
Easy project development due to the use of a single STEP 7 project for all
variants.
Small engineering effort for configuration, construction and wiring.
Standardization of hardware and software for the various variants of a
machine.