Safety Laser Scanner
SZ-V32N
Communications Manual
Introduction
This user’s manual describes handling, operation, and
precautionary information related to communication for the
SZ-V32N Safety Laser Scanner (“SZ-V
”
). Read this user’s
manual thoroughly before operating the SZ-V in order to
understand the device features.
Always keep this manual in a safe place for future reference.
Ensure that the end user of this product receives this user’s
manual.
Also for details relating to SZ-V except for the communication,
refer to “SZ-V Series Instruction Manual” and “SZ-V Series
User’s Manual”.
Symbols
The following symbols alert you to important messages.
Be sure to read these messages carefully. Be sure to read
these messages carefully.
It indicates a hazardous situation which, if not
avoided, will result in death or serious injury.
It indicates a situation which, if not avoided,
could result in product damage as well as
property damage.
It indicates tips for better understanding or useful
information.
It indicates the reference pages in this manual or
the reference pages in separate manuals.
558GB
2
1 Before Use
1-1 Communications on the SZ-V
The SZ-V can read and write data by communicating with
PLCs and computers via Ethernet.
The data received from the communication
of UDP, EtherNet/IP
TM
or PROFINET cannot
be used for the safety control system. When
used in error, there is a possibility that the
operator of the device may be threatened
with injury or even death.
As the SZ-V has two Ethernet ports, connection by daisy
chain is possible. If connecting multiple SZ-Vs and Ethernet
devices, the number of man-hours required for wiring can
be reduced. Also, media redundancy protocol (MRP) for
PROFINET is supported. However, device level ring (DLR)
for EtherNet/IP is not supported.
Example system
PC with SZ-V Congurator
Ethernet
device
SZ-V32N
Ethernet
device
PLC for Control
HUB
LAN Cable
Expansion
cable for SZ
Ethernet port functions
The two Ethernet ports built-in to the SZ-V work as an
AutoMDIX-compatible switching hub.
If using the SZ-V Ethernet port as a switching hub, note that
the switch operations are different, depending on the SZ-V
operating state.
SZ-V operating state Switch operation
Power OFF Operation is stopped
Changing
communication
protocol
When the communication protocol
changes, the link is temporarily
suspended.
Other setting changes Operation continues
The SZ-V is compatible with the ve communication
methods below.
(1) Communicating with the SZ-V Congurator
It is possible to communicate with the SZ-V conguration
software (SZ-V Congurator) via Ethernet. It is also possible
to communicate with the SZ-V Congurator via USB.
For details on how to communicate via USB, see “SZ-V
Series User’s Manual”.
(2) Communicating with a PLC or computer via
UDP
The SZ-V measurement distance data and the error status
can be readout via UDP. This is useful when it is necessary
to continuously readout the measurement distance data of
all beams.
“2 UDP Communication” (Page 10)
(3) Communicating with a PLC or computer via
EtherNet/IP
The SZ-V measurement distance data and the error status
can be readout via cyclic and message communications.
“3 EtherNet/IP Communication” (Page 26)
PC or PLC, etc.
with EtherNet/IP compatible board
3
(4) Communicating with a PLC or computer via
PROFINET
The SZ-V measurement distance data and the error status
can be readout via Cyclic and Acyclic communications.
“4 PROFINET Communication” (Page 36)
PC or PLC, etc.
with PROFINET compatible board
(5) Communicating with a PLC via PROFIsafe
The SZ-V is compatible with PROFIsafe communication.
When using PROFIsafe communication, see “5 PROFIsafe
Communication” (Page 45)
Safety PLC
It is possible to use some of the ve communication
protocols above at the same time, depending on the
communication protocol that is selected.
For example, one can receive the SZ-V measurement
distance data via UDP while connecting to the SZ-V from
another computer using the SZ-V Congurator.
However, it is not possible to connect to one SZ-V from
multiple computers at the same time using the SZ-V
Congurator.
Communication protocols that can be used
simultaneously
Selected
communication
protocol
Communication protocols that
can be used simultaneously
(1) SZ-V Congurator
(2) UDP
(3) EtherNet/IP
(4) PROFINET
(5) PROFIsafe
UDP
ü ü
EtherNet/IP
ü ü ü
PROFINET
ü ü ü
PROFIsafe
ü ü ü ü
“1-5 Setting the IP Address and Protocol” (Page 5)
What can be performed with each
communication protocol
Function
Communication protocols
(1) SZ-V Congurator
(2) UDP
(3) EtherNet/IP
(4) PROFINET
(5) PROFIsafe
Set the SZ-V protection
zones
ü
Set the SZ-V functions
ü
Monitor the SZ-V
detection status with
monitor view
ü
Receive the protection
zone state for use
in the safety control
system
ü
Receive measurement
distance data
ü ü ü
Receive the SZ-V Error
status
ü ü ü ü ü
Receive the SZ-V Error
History
ü
Monitor the SZ-V
camera images/videos
ü
Readout the encoder
speed
ü ü ü
Manage SZ-V Banks
ü
4
1-2 Measurement Distance Data and
Beam Number
The SZ-V scans the internal optics and measures the
distance in increments of 0.1°.
(Increments of 0.2° if the Operating mode is High Speed
mode.)
The distance that the SZ-V measures can be readout via
UDP, EtherNet/IP and PROFINET communications. The
measurement distance data can be received between -5.2°
and 185.2° in increments of 0.2°.
(Increments of 0.4° if the Operating mode is High Speed
mode.)
Additionally, the -5.2° position is called the “0 beam”.
y
In Standard mode, the 185.2° position is the 952nd beam.
90° (476th)
0° (26th)180° (926th)
Protection zone
origin
-5.2° (0 beam)185.2° (952th)
y
In High Speed mode, the 185.2° position is the 476th beam.
90° (238th)
0° (13th)180° (463th)
Protection zone
origin
-5.2° (0 beam)185.2° (476th)
Measured value stabilization lter
To improve the stability of the measurement distance data,
a ltering process can be performed. This lter processing is
called the “measured value stabilization lter
”
.
When using the measured value stabilization lter, stability
improves, but response time decreases (High Speed mode:
+ Approx. 80 ms, Standard mode: + Approx. 160 ms).
The settings for the measured value stabilization lter can
be changed in the SZ-V Congurator.
For details, see the “SZ-V Series User’s Manual”.
1-3 Workow Until Test Run
Connect the Ethernet cable
“1-4 Connecting the Ethernet Cable” (Page 5)
Congure the SZ-V zone and functions using the
software.
For more details, see the “SZ-V Congurator User’s
Manual”
Set the IP address and communication protocol
“1-5 Setting the IP Address and Protocol” (Page 5)
Receive the data via the network
“2 UDP Communication” (Page 10)
“3 EtherNet/IP Communication” (Page 26)
“4 PROFINET Communication” (Page 36)
“5 PROFIsafe Communication” (Page 45)
5
1-4 Connecting the Ethernet Cable
This section describes how to connect an Ethernet cable to
the SZ-V.
Connection conguration
0.3m : SZ-VNC03
RJ-45 M12-4pin, male
M12-4pin, male
M12-4pin, female M12-4pin, male
RJ-45
2m : OP-88089
5m : OP-88090
10m : OP-88091
20m : OP-88092
2m : OP-88086
5m : OP-88087
10m : OP-88088
Usable cables
When connecting the Ethernet cable to the SZ-V32N, make
sure to use the SZ-VNC03 to maintain its waterproof and
dustproof ratings.
Connect to the SZ-VNC03 or similar cable with the optional
cables recommended in the “SZ-V Safety Laser Scanner
Brochure” or cables that meet the specications below.
y
Category 5 or higher shielded twisted pair (STP) cable
y
Category 5 or higher unshielded twisted pair (UTP) cable
In order to conform with EU regulations, a category 5e or
higher cable may be necessary.
For details, see “Precautions on Regulations and Standards
”
in the “SZ-V Series Instruction Manual”.
As the SZ-V Ethernet port supports AutoMDIX,
either a straight cable or a crossover cable can be
used.
How to connect the cable
Open the Ethernet cable cover on the display unit and
connect the SZ-VNC03. The SZ-VNC03 can be connected
to either one of the Ethernet ports.
“1-1 Communications on the SZ-V” (Page 2)
1-5 Setting the IP Address and Protocol
For an SZ-V that has not been assigned an IP address,
the IP address can be set with one of the following four
methods:
(1) Via USB (SZ-V Congurator)
(2) Via Ethernet (SZ-V Congurator)
(3) Via Ethernet (BOOTP/DHCP server)
(4) Via Ethernet (PROFINET IO Controller software)
When using the SZ-V Congurator, the IP address will be
set at the same time as the other communication related
settings.
If the IP Address needs to be set independently from the
other settings, use either method (3) or (4).
(1) Via USB
By connecting a computer with the SZ-V Congurator
installed on it to the SZ-V with a USB cable, the SZ-V IP
address can be set via USB.
1
Connect a computer and the SZ-V with a USB
cable
Use a USB cable (OP-51580 or OP-86941) to connect
the SZ-V to the computer.
(SZ-V series)
USB cable
(OP-86941)
SZ-V series conguration software
<SZ-V Congurator>
If the setting cover is open, the enclosure
rating of IP65 cannot be satised. Make
sure that dust does not enter the inside
during this time.
2
Start the SZ-V Congurator
When creating new settings, click [Create a new
conguration le] - [OK].