没有合适的资源?快使用搜索试试~ 我知道了~
G6F-AD2A使用手册
需积分: 5 0 下载量 113 浏览量
2024-04-18
10:28:28
上传
评论
收藏 327KB PDF 举报
温馨提示
试读
27页
LS系列G6F-AD2A使用手册
资源推荐
资源详情
资源评论
User
User User
User’
’’
’s Manual
s Manuals Manual
s Manual
LG Programmable Logic Controlle
r
G6F – AD2A
GLOF
A
GLOF
A
GLOF
A
GLOF
A
LG
LG LG
LG
Industrial Systems
CONTENTS
Chapter 1. INTRODUCTION
1.1 Features
1-1
1.2 Glossary
1-1
1.2.1 A-Analog Value 1-1
1.2.2 D-Digital Value 1-1
1.2.3 Analog / Digital Conversion Characteristics 1-2
Chapter 2. SPECIFICATIONS
2.1 General Specifications
2-1
2.2 Performance Specifications
2-2
2.3 Names of Parts and Functions
2-3
2.4 I/O Conversion Characteristics
2-4
2.4.1 Voltage Input Characteristics 2-4
2.4.2 Current Input Characteristics 2-5
2.4.3 Simultaneous Voltage and Current Input Characteristics 2-5
2.4.4 Analog Input and Digital output Characteristics 2-6
2.5 Averaging Process
2-6
Chapter 3. INSTALLATION AND WIRING
3.1 Installation
3-1
3.1.1 Installation Ambience 3-1
3.1.2 Handling Precautions 3-1
3.2 Wiring
3-2
3.2.1 Wiring Precautions 3-2
3.2.2 Wiring Examples 3-2
Chapter 4. FUNCTION BLOCK
4.1 Insertion of the Function Block for the A/D Conversion Module on the GMWIN
4-1
4.2 Local Function Block
4-2
4.2.1 Module Initialization (AD2INI) 4-2
4.2.2 Module Reading - Array Type (AD2ARD) 4-3
4.2.3 Module Reading - Single Type (AD2RD) 4-3
4.3 Errors on Function Block
4-4
Chapter 5. PROGRAMMING
5.1 Programming for Distinction of A/D Conversion Value
5-1
5.2 Programming for Display of A/D Conversion Value and Error Code on BCD Display... 5-5
Chapter 6. DIMENSIONS
6.1 G6F-AD2A
6-1
Be sure to read carefully the safety precautions given in data sheet and user’s manual before operating the module
and follow them.
The precautions explained here only apply to the G6F-AD2A
For safety precautions on the PLC system, see the GLOFA GM6 User’s Manuals.
A precaution is given with a hazard alert triangular symbol to call your attention, and precautions are represented
as follows according to the degree of hazard.
However, a precaution followed with can also result in serious conditions.
Both of two symbols indicate that an important content is mentioned, therefore, be sure to observe it.
Keep this manual handy for your quick reference in necessary.
SAFETY PRECAUTIONS
WARNING
!
If not provided with proper prevention, it can cause death or fatal
injury or considerable loss of property.
CAUTION
!
If not properly observed, it can cause a hazard situation to result
in severe or slight injury or a loss of property.
CAUTION
!
CAUTION
!
Design Precautions
Do not run I/O signal lines near to
high voltage line or power line.
Separate them as 100 mm or
more as possible. Otherwise,
noise can cause module mal-
function.
CAUTION
!
Installation Precautions
Operate the PLC in the environ-
ment conditions given in the
general specifications.
If operated in other environment
not specified in the general
specifications, it can cause an
electric shock, a fire, malfunction
or damage or degradation of the
module
Make sure the module fixing pro-
jections is inserted into the mod-
ule fixing hole and fixed.
Improper installation of the mod-
ule can cause malfunction, dis-
order or falling.
CAUTION
!
Wiring Precautions
When grounding a FG terminal, be sure to provide class 3 grounding which is dedicated to
the PLC.
Before the PLC wiring, be sure to check the rated voltage and terminal arrangement for
the module and observe them correctly.
If a different power, not of the rated voltage, is applied or wrong wiring is provided, it can
cause a fire or disorder of the nodule.
Drive the terminal screws firmly to the defined torque.
If loosely driven, it can cause short circuit, a fire or malfunction.
Be careful that any foreign matter like wire scraps should not enter into the module.
It can cause a fire, disorder or malfunction.
WARNING
!
Test Run and Maintenance
Precautions
Do not contact the terminals
while the power is applied.
It can cause malfunction.
When cleaning or driving a termi-
nal screw, perform them after the
power has been turned off
Do not perform works while the
power is applied, which can
cause disorder or malfunction.
CAUTION
!
Do not separate the module from
the printed circuit board(PCB), or
do not remodel the module.
They can cause disorder, mal-
function, damage of the module
or a fire.
When mounting or dismounting
the module, perform them after
the power has been turned off.
Do not perform works while the
power is applied, which can
cause disorder or malfunction.
CAUTION
!
Waste Disposal Precautions
When disposing the module, do it as an industrial waste.
剩余26页未读,继续阅读