汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf

所需积分/C币:9 2019-10-11 00:45:09 3.65MB PDF
41
收藏 收藏
举报

汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715)pdf,
Introduction NICE1000 w User Manual ■ Product Checking Upon unpacking, check Whether the nameplate model and controller ratings are consistent with your order. The box contains the controller, certificate of conformity, user manual and warranty card Whether the controller is damaged during transportation. If you find any omission or damage, contact your supplier or Monarch immediately ■ First- time Use For users who use this product for the first time, read the manual carefully. If you have any problem concerning the functions or performance, contact the technical support personnel of monarch to ensure correct use CE Mark The CE mark on the Nice1000 declares that the controller complies with the European low voltage directive(LVD)and EMC directive C∈ ■ Standard compliance The NICE1000 series controller complies with the following LVD and EMc directives and standards Directive Directive Code Standard EN61800-3:2004+A1:2012 EMC Directive 2004/18/EC EN12015:2004 EN12016:2004+A1:2008 LVD Directive 2006/95/EC EN61800-5-1 The NICE1000 series controller complies with the requirements of the EMc standard on the condition of correct installation and use by following the instructions in chapter 9"EMC NICE1000 new User Manual Introduction Introduction 1. Comparison with the NICE1000 The following table lists the comparison between the NICE1000 and the NICE1000 te N|CE1000 NICE1000 eW Standard: 6 Standard: 8 Maximum number of floors (can be extended to 8) (can be extended to 16 Maximum elevator speed1 m/s 1.75m/s Digital input: 24 Digital input: 24 Button input and indicator Button input and indicator output: standard 20 (can be output: standard 26(can lo terminals extended to 26) be extended to 50) Relay output: standard 21 Relay output: standard 21 (can be extended to 24) (can be extended to 27) gher-voltage input: 3 Higher-voltage input: 3 CANbus None 1 X CANbus Modbus None 1 x Modbus Separate control for Integrated control Motor driving type synchronous and for synchronous and asynchronous motors asynchronous motors Push-pull encoder Open-collector incremental No-load-cell startup Supporting SIN/COS encoder encoder UVW encoder SIN/COS encoder · Endat encoder Sensorless vector control Sensorless Control mode Closed-loop vector control Closed-loop vector control (CLVC) (CLVC) · V/F control Commissioning via Android cell phone(not providing Not support Support English version currently) PG card for asynchronous motor Not requiring PG card Requiring MCTC-PG-A2 Extension card MCTC-KZ-B MCTC-KZ-D The pg card and the extension card use the same the pg card and the of optional part nterface on the mcb. and extension card can be used they cannot be used at the at the same time same time Introduction NICE1000 w User Manual 2. Connection to peripheral devices Three-phase AC ithin the allowable power supply ower supply specification of the controller proper breaker to Molded case circuit in-rush current s into the controller breaker(MCCB)or earth leakage circuit breaker(ELCB) External operation panel electromagnetic contactor. Do not Electromagnetic se it to start or stop the controller because such operation reduces the service life of the controller sI Suppress the high order harmonic AC input reactor to improve the power factor. Operation box 出是 N|cE1000 input side integrated elevator Reduce the electromagnetic ③3④ interference on the input side. ⑦8 Hall display board Top flo Ground Reliably ground the controller to prevent A Output electric shock uIng Hall display board ttom floor Moto For model selection of the peripheral electrical devices, refer to section 3. 4 The NiCe1000 in the preceding figure is the standard model For information about other structures refer to section 2.5 NICE1000 new User Manual Introduction 3. Basic function list Function Description Remarks Common Running Functions Integrated control Switchover between the for synchronous It can drive both AC asynchronous motor and and asynchronous permanent magnetic synchronous motor(PMSM) motors motors easily by modifying F1-25 In automatic running or attendant state, this function Collective Full collective enables the elevator to respond both car calls and hall calls. Passengers at any service floor can call the selection set in elevator by pressing the up call button and down call FE-00 button Door open time The system automatically determines different door setting open time for door open for call, command, protection, Set in group Fb or delay according to the set door open holding time n automatic running state, passengers can press Door open holding the door open button in the car to delay door open to Set in group Fb facilitate goods to be moved in or out Door machine You can set the required service floors of the door Set in Fb-02 and service floor setting machines Fb-04 Door pre-close During door open holding in automatic running state by the door close passengers can press the door close button to close button the door in advance, which improves the efficiency Floor number The system supports display of floor numbers in display setting combinations of numbers and letters, which meets the Set in group FE requirements of special conditions Light curtain signal If the door is blocked by stuff during door close, the udgment ht curtain acts and the elevator opens the door this function is invalid in fire emergency state ndependent control When there are two doors for a car, this function of the front door implements independent and automatic control on the/ Refer to section and back de ding to your requirements 5.2.3 in Chapter 5 If the door lock is not applied after the elevator Repeat door close rforms door close for a certain time the elevator Fb-08 (Door close automatically opens the door and then closes the door protection time) repeatedl The systems implements automatic accurate leveling Auto-leveling based on the floor pulse counting and up/down leveling feedback signals The system allows the elevator to automatically acceleration respond to calls from the service floors during acceleration dle elevator In automatic running state, the elevator automatically F9-00 (Idle time returning to base returns to the set parking floor and waits for passengers if there is no car call or hall call within the before returning set time to base floor) Introduction NICE1000 w User Manual If the door open time exceeds the door open protection Landing at another time but the door open limit signal is still inactive, the elevator closes the door and then automatically runs to the next landing floor. The system reports fault Err55 When the door fails to close within the set time due Forced door close to the action of the light curtain or safety edge, the door slowly, and gives a prompt tone stat elevator enters the forced door close state closes the You can enable or disable the system service for Service floor setting certain floors flexibly based on actual requirements Set in F6-05 Enabled when The elevator does not respond to any call, and the Bit9 of fE-13 is Independent door needs to be closed manually. In the case of group and independent running control, the elevator runs independently out of the group control system running input of the mcb is active Attendant running In attendant state, the running of the elevator is controlled by the attendant When the elevator is in non-inspection state and Low-speed self- stops at non-leveling area, the elevator automatically rescue uns to the leveling area at low speed if the safety requirements are met, and then opens the door Door control You can set whether the system keeps outputting function commands after door open limit and door close limit based on the type of the door machine Car arrival gong After the elevator arrives at the destination floor the CtB gives a prompt tone Automatic The system automatically implements startup torque startup torque compensation based on the current car load, achieving Set in F8-01 compensation smooth startup and improving the riding comfort The system automatically calculates and generates Direct travel ride the running curves based on the distance, enabling the elevator to directly stop at the leveling position without Automatic The system automatically calculates the optimum generation of speed curve compliant with the human-machine function principle based on the distance, without being optimum curve limited by the number of curves or short floor Service suspension When the elevator cannot respond to hall calls, the output corresponding terminal outputs the service suspension Running times In automatic running state, the system automatically Recorded in F9- recording records the running times of the elevato 05andF9-06 Running time The system automatically records the accumulative Recorded in recording power-on time, working hours, and working days of the elevator F9-03 6 NICE1000 new User Manual Introduction If the system detects that the door lock circuit is Automatic door abnormal during door open/close, the elevator Fb-09(Door open/ open upon doo automatically opens and closes the door again, and close protection lock abnormality reports a fault after the set door open/close times is times reached When the car is full-loaded in automatic running state, the elevator does not respond to hall calls from the Full-load direct passing floors. These halls calls, however, can still be runnIng registered, and will be executed at next time of running (in the case of single elevator)or by another elevator (in the case of parallel control) Overload protection nen the car load exceeds the rated elevator load the elevator alarms and stops running Fault data The system automatically records detailed information of faults, which helps improve the efficiency of Set in group FC recording maintenance and repair Inspection-related Functions Shaft auto-tuning is required before first-time automatic running During shaft auto-tuning the elevator runs Shaft auto-tuning from the bottom floor to the top floor at the inspection Refer to section 5.1.2 speed and automatically records all position signals in the shaft User-defined You can view the parameters that are modified and Set in FP-02 parameter display different from the default setting After entering the inspection state, the system cancels Inspection running automatic running and related operations. You can press the up or down call button to make the elevator jog at the inspection speed With simple meter setting the syst bta Refer to section Motor auto-tuning the motor parameters no matter whether the motor is 5.1.1 with-load or without load Every time the elevator runs to the terminal floor, the Floor position system automatically checks and corrects the car sition information based on slow-do itch 1. and correction eliminates over travel top terminal or bottom terminal with use of the slow -down switches Considering inaccurate running control at high Dual-speed for inspection speed but long running time at low Inspection inspection speed, the system provides the dual- speed curve for inspection, which greatly improves the efficiency at inspection The test running includes the fatigue test of a new elevator car call floor test hall call test. and tests Test running such as hall call response forbidden, door open/close Set in F6-10 forbidden terminal floor limit switch shielded and overload signal shielded Introduction NICE1000 w User Manual Fire Emergency and Security Functions Returning to After receiving a fire emergency signal, the elevator base floor at fire does not respond to any call but directly runs to the fire emergency floor and waits emergency floor) emergency After the elevator enters the firefighter running mode, door open/close is implemented by the jog operation F6-68( Fire Firefighter running /optional) by using the door open and close buttons emergency responds to only car calls and only one call can be function selection) registered once In automatic running state, when the elevator lock itch acts or the set elevator time is reached the Elevator lock elevator cancels all registered calls, returns to the F6-04(Elevator elevator lock floor, stops running, and turns off the lock floor) np and fan in the roubles Faults are classified into different levels based on the Refer to Chapter based on fault level severity. Different levels of faults are rectified using 8 Ru The system detects the running state of the elevator in real time. If the elevator speed exceeds the limit, the prevention system immediately stops running of the elevator The system automatically identifies power failure and 70 especially Automatic used for identification of outputs the relay signal for emergency evacuation automatic switchover to implement emergency emergency power evacuation at power failure evacuation switchover For the synchronous motor, when the power supply is interrupted, the system can perform automatic switchover between shorting stator braking mode and controller drive mode, implementing quick and stable F6-69 Automatic running seIT-rescue mode switchover at (Emergency power failure Shorting stator braking mode: Upon power failure evacuation UPS is used, the motor stator is shorted, and the brake function selection) is automatically released, making the car move slowly under the effect of the weighing difference between the car and the counterweight Running direction When the power supply is interrupted, the system F6-69 identification at can automatically identify the current car load and (Emergency power failure determine the running direction evacuation function selection) Base floor After detecting a position abnormality, the system runs verification the elevator to each floor until reaching the terminal floor for verification, guaranteeing system security Passenger The system automatically determines the fault level. If unloading first upon the safety running conditions are met, the elevator first runs to the leveling position to unload passengers Interference degree The system judges the degree of communication Viewed in FA-24 judgment interference 8- NICE1000 new User Manual Introduction When the earthquake detection device acts and Earthquake inputs a signal to the system, the elevator lands at the protection nearest floor and stops running. After the earthquake signal becomes inactive and the fault is reset manually, the elevator restores to normal running Independent The NICE1000new system supports not only three working power phase 380 VAC but also single-phase 220 VAC to supply meet different applications of the power supply systen (such as 220 V UPS The system detects the bus voltage and automatically Automatic voltage adjusts the running speed of the elevator to adapt to identification the situation of insufficient power from power supply (such as emergency UPS) Parallel Control and other Functions Parallel control The system supports parallel control of two elevators. Refer to 5.2.2 Dispersed waitingfloors In parallel control, the elevators can wait at different Set in Fd-05 If the parallel control exit switch of a certain elevator in a parallel control system is valid or the time for exiting Parallel control exit the parallel control is reached, the elevator exits arallel control and runs independently. this does not affect normal running of the parallel control system If an elevator in the parallel control system cannot respond to calls in time due to faults the elevator Parallel control automatic exit automatically exits the parallel control system and runs independently. This does not affect normal running of the parallel control system The system automatically judges the number of passengers in the car and compares it with the number Anti-nuisance of registered car calls. If there are excessive car calls,F8-13(Anti function the system determines that it is nuisance and cancels nuisance function all car calls. In this case, passengers need to register correct car calls again Prompt of non-door The system gives a prompt when the elevator stops at zone stop a non-door zone area due to faults Interface for Residential intelligent The system provides an interface for intelligent monitoring board residential management to perform remote monitoring MCTC-MIB on the state of elevators in the residential district management equired Parameter copy You can upload and download parameters by using MDKE6 operation the operation panel MDKE6 panel required Energy-Saving Functions If there is no running command within the set time, the F9-01(Time for Car energy-saving system automatically cuts off the power supply to the fan and lamp to lamp and fan in the car be turned off)

...展开详情
试读 127P 汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf
立即下载
限时抽奖 低至0.43元/次
身份认证后 购VIP低至7折
一个资源只可评论一次,评论内容不能少于5个字
您会向同学/朋友/同事推荐我们的CSDN下载吗?
谢谢参与!您的真实评价是我们改进的动力~
  • 至尊王者

关注 私信
上传资源赚钱or赚积分
最新推荐
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf 9积分/C币 立即下载
1/127
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第1页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第2页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第3页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第4页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第5页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第6页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第7页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第8页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第9页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第10页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第11页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第12页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第13页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第14页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第15页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第16页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第17页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第18页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第19页
汇川-《NICE1000new电梯一体化控制器用户手册》-英文 20140715).pdf第20页

试读结束, 可继续阅读

9积分/C币 立即下载