omron定时器H5CX资料.pdf

所需积分/C币:10 2019-10-22 22:07:32 1.54MB PDF
收藏 收藏
举报

omron定时器H5CX资料pdf,omron定时器H5CX资料
H5CX OROn H5CX Specifications Ratings Item H5CX-A H5CXA11口 H5CXL8口 Classification Digital timer Rated supply voltage 100 to 240 VAC(50/60 Hz), 24 VAC (50/60 Hz) /12 to 24 VDC (permissible ripple: 20%(p-p)max Operating voltage range 85%to 110% rated supply voltage(12 to 24 VDC: 90% to 110%) Power consumption prox. 6. 2 Va at 264 Vac Approx 5. 1 Va at 26.4 VAC Approx 2. 4 W at 12 VDC Moun nethod Panel mounting Panel mounting, surface mounting, DIN track mounting External connections Screw terminals 11-pin socket 8-pin socket Terminal screw tightening 0.5 N.m max. torque Display 7-segment, negative transmissive LCD; 7-segment, negative transmissive LCD Present valu Present valuc 11.5-mm-high characters 11.5-mm- high characters, red red or green(programmable Set value: 6-mm-high characters, green Set value: 6-mm-high characters, green Digits 4 digits Time ranges 9.999s0.001- s unit).99.99s(0.01- s unit,9999s(0.1-sunt,9999s(1-sunt)99min59s(1- s unit 999.9 min(0. 1-min unit), 9999 min(1-min unit), 99 h 59 min(1-min unit), 999.9 h(0.1-h unit ), 9999 h(1-h unit) Timer mode Elapsed time(Up), remaining time(Down), selectable Input signals Start, gate, reset Start reset Input method No-voltage input/voltage input(selectable) No-voltage In No-voltage Input ON impedance: 1 kS2 max ON impedance: 1 ke max. Leakage current: 5 to 20 mA when 0 Q2) eakage current: 5 to 20 mA ON residual voltage: 1 max when 0 22) OFF impedance: 100 kQ2 min ON residual voltage: 1V max Voltage Input OFF impedance: 100 ke min th (logic)level: 4. 5 to 30 VDC Low(logic)level: 0 to 2 VDC (Input resistance: approx. 4.7 ke) I Start, reset, gate Minimum input signal width: 1 or 20 ms(selectable, same for all input Power reset Minimum power-opening time: 0.5 s(except for A-3, b-1, and F mode) Reset system Power resets(except for A-3, b-1, and F modes), external and manual reset Sensor waiting time 260 ms max ( Control output is turned OFF and no input is accepted during sensor waiting time. Output modes A,A-1,A-2,A-3, b b-1,d,E,F,, Twin-Timer ON START/OFF START One-shot output time 0.01to9999s Control output SPDT contact output: 5 A at 250 VAC, resistive load(cosd=1) Minimum applied load: 10 mA at 5 VDC(failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC max residual voltage: 1.5 VDC max(Approx 1V Conforms to EN60947-5-1 for Timers with Contact Outputs and EN60947-5-2 for Timers with Transistor out NEMa B300 Pilot duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5A resistive load at 240 VAC Key protection Yes Memory backup EEPROM(overwrites: 100,000 times min. that can store data for 10 years min Ambient temperature Operating: -10 to 55C(10 to 50 C if timers are mounted side by side)(with no icing or condensation) Storage: -25 to 65 C(with no icing or condensation Ambient humid ity 25%to85%RH Case color Black(N1.5) Attachments Waterproof packing flush mounting adapter H5CX OmROn H5CX Characteristics H5CXA國A11口/-L8口 Accuracy of operating Power-On start: +.01%+50 ms max. Rated against set value time and setting error(in- Signal start: +0.005+30 ms max. Rated against set value voltage influences)(See Signal start for transistor output model:#0.005%#3 ms max. (See note 2) note 1.) If the set value is within the sensor waiting time at startup the control output of the H5cX will not turn on until the sensor waiting time passes Insulation resistance 100 M min.(at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts and between non-continuous contacts Dielectric strengt 2,000 VAC, 50/60 Hz for 1 min between current-carrying terminals and non-current-carrying metal parts 000 VAC. 50/60 Hz for 1 min between non-continuous contacts Impulse withstand voltage 3 kv(between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC 4.5 kv (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 Vac/12 to 24VDC Noise immunity +1.5 kv (between power terminals)for 100 to 240 VAC,+ V for 24 VAC!12 to 24 VDC, and +600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise) Static immunity Destruction 15 kV Malfunction:8k∨ Vibration resistance Destruction: 10 to 55 Hz with 0. 75-mm single amplitude each in three directions Malfunction: 10 to 55 Hz with 0. 35-mm single amplitude each in three directions Shock resistance Destruction 294 m/s each in three directions Malfunction 98 m/s each in three directions Life expectancy Mechanical: 10,000,000 operation min Electrical: 100,000 operations min (5 A at 250 VAC, resistive load Approved safety UL508/Recognition(H5CX-L8L: Listing only with OMRON,'s P2CF-08 or P3G-08 socket), CSA C22.2 No standards(See note 3 )14, conforms to EN61010-1(Pollution degree 2/overvoltage category ID) Conforms to VDE0106/P100(finger protection EMC EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission ac mains. EN5501 1 Group 1 class a (EMS EN61326 Immunity ESD EN61000-4-2: 4 kv contact discharge(level 2) 8 kV air discharge (level 3) Immunity RF-interference EN61000-4-3: 10 Vim(Amplitude-modulated, 80 MHz to 1 GHz)(level 3) 10 V/m(Pulse-modulated, 900 MHz+5 MHz)(level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V(0. 15 to 80 MHz) (according to EN61000-6-2) Immunity Burst EN61000-4-4: 2 kV power-line(level 3); kVl/0 signal-line(level 4 Immunity Surge EN61000-4-5: 1 kv line to lines(power and output lines)(level 3) 2 kv line to ground (power and output lines)(level 3 1 kv line to ground (o signal line) mmunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100%(rated voltage) Degree of protection Panel surface: IP66 and NEMA Type 4 (indoors)(See note 4. Weight H5CX-AL: Approx. 135 g, H5CX-A11L-L8L: Approx. 105 g Note 1. The values are based on the set value 2. The value is applied for a minimum pulse width of 1 ms 3. To meet UL listing requirements with the H5CX-L8, an OMRON P2CF-08-dor P3G-08 Socket must be mounted on the Timer 4. Waterproof packing Y92S-29 is necessary to ensure IP66 waterproofing between the H5CX and installation panel a Engineering Data(Reference Values) 古 Reference: A maximum current of o 15 a can be switched at 1000 125 VDC (cosd=1)and a maximum current of 0.1 A can be switched if l/r is 7 ms. In both cases a life 500 of 100,000 operations can be expected. The mir mum applicable load is 10 mA at 5 VDC(failure -30 VDC L/R=7ms 250VDC30 VDC cos中 50 VAC COSφ=0.4 Load current(A) H5CX OROn H5CX Nomenclature Indicator Operation Key O Reset Indicator (orange) TIMER 8 Mode Key (Changes modes and setting items) (2)Key Protection Indicator(orange) 9 Reset Key Control Output Indicator (orange) 2:3 (Resets present value and output) SET12 4 Present Value MODE ① Up Keys1to4 (red or green(programmable)for H5CX-A models red for h5cx-a11 ③會」‖ ① Down Keys1to4 y-L models) omRon H5CX Character height: 11.5 mm Front view Front color: black 6 Time Unit Display (orange) (f the time range is o min oh, 0.0 h Switches oro ho min, this display flashes to indicate timing operation (12) Key-protect Switch 6 Set value(green) (default setting) OFF ON Character height: 6 mm ⑩ ⑦ Set value1,2 Display 299 (13) DIP Switch Case color: black Operation ■ Block Diagra Output circuit ----- insulation Display circuit Input circuit Internal control circuit Power supply circuit Note: Power circuit is not insulated from the input circuit, except for H5CX-A11/-Al1S, which have basic insulation ■ lO Functions tem Description Inputs Start signal Stops timing in A-2 and A-3(power On delay) modes Start timing in other modes Reset Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value. Count inputs are not accepted and control output turns off while reset input is on Reset indicator is lit while reset input is oN Gate Inhibits timer operation Outputs Control output(OUT) Outputs take place according to designated operating mode when timer reaches correspond H5CX OmROn H5CX Setting Procedure Guide Settings for Timer Operation Use the following settings for all models except the H5CX-L8O Refer to Quick Setup- Advanced Timer Functions for the H5CX-L8O When Using Basic Functions Only The settings can be performed easily with the diP switch Basic functions -For details on setting methods, refer to Quick Setup-Basic Timer Functions on · Time ran 0001sto999.9 except 9, 999 h and 9, ggg min) the following page Output mode(A, A-2, E, F) Timer mode(UP/DOWN) 个 Input signal width(20 ms/1 ms) OFF When Using Other Time Ranges( 9, 999 h, When Using More Specific Settings(Output 9, 999 min) and Output Modes(A-1, A-3, b, b-1 Time, NPN/PNP Input Mode, Display Color, Key d, and z) Protect Level) All the functions can be set with the operation keys Setting for items other than the basic functions can be - For details on the setting methods, refer to Quick Setup performed with the operation keys Advanced Timer functions - For details on the setting methods, refer to Quick Setup Advanced timer functions Note: At the time of delivery, the H5CX is set for timer operation Settings for Twin Timer Operation Use the following settings for all models except the H5CX-L8O Refer to Operation -Timer/win Timer Selection Mode for the H5CX-L80 When Using Basic Functions Only The settings can be performed easily with the DIP switch Basic Functions For details on setting methods, refer to Quick Setup- Basic Twin Timer Time range(0.01 s to 99 min 59 s) Function ON/OFF Start mode 12345678 (Repeat cycle OFF start/Repeat cycle On start) Timer mode(UP/DOWN) 个 Input signal width(20 ms/1 ms) OFF ■■■■■■ When Using other Time Ranges( 999.9 min When Using More Specific Settings(NPN/PNP 9,999 min, 99 h 59 min, 999.9 h, 9, 999 h, 9.999 s) Input Mode, Display Color, Key Protect Level) All the functions can be set with the operation key Setting for items other than the basic functions can be For details on the setting methods, refer to Quick Setup performed with the operation keys Advanced twin Timer functions m For details on the setting methods, refer to Quick setup Advanced Twin Timer functions Note: At the time of delivery, the H5CX is set for timer operation H5CX OmROn H5CX Operation -Timer Function Quick Setup- Basic Timer Functions Settings for basic functions can be performed with just the DIP switch. Be sure to set pin 1 to ON 23 5678 个 OFF Item OFF ON Pin 2 Pin 3 Pin 4 Time range DIP switch set- Disabled Enabled ON ON ON 0.001sto9999s tings enable disable OFF OFF OFF 0.01sto9999s 234 Time range Refer to the table on the right ON OFF OFF 0.1sto9999s OFF OFF s to 9999s ON ON OFF 0 min 01 s to g9 min 59s Output mode Refer to the table on the right. OFF OFF ON 0.1 min to 999.9min Timer mode Elapsed time Remaining time ON OFF ON 0h01 min to (UP DOWN 99 h 59 min Input signal 20 ms OFF ONON0.1 h to 999.9h width Note: All the pins are factory-set to OFF Pin 5 Pin 6 Output mode OFF OFF A mode(signal on dela ( power reset opera ON OFF A-2 mode: ( r oN Easy Confirmation of Switch Settings Using Indicators delay( ) power reset op The ON/OFF status of the dIP switch pins can be eration) confirmed using the front display. For details, refer to OFF ON E mode(interval: power Operation in Timer Function Run Mode eset operation) ON ON F mode(accumulative: power hold operation Note: 1. Be sure to set pin 1 of the dIP switch to ON. If it is set to OFF, any DIP switch settings will not be enabled 2. Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF. 3. There is no DIP switch on the H5CX-L8Q. For details on the setting methods, refer to Quick Setup- Advanced Timer Function 4. When using time ranges or output modes that cannot be set with the dIP switch, all of the settings have to be made using the operation keys. For details on the setting methods, refer to Quick Setup- Advanced Timer Functions Detailed Settings After making DIP switch settings for basic functions, detailed settings(see note)can be added using the operation keys For more details, refer to Quick Setup- Advanced Timer Functions Note: Key protect level, output time, display color, NPN/PNP input mode H5CX OmROn H5CX a Quick Setup- Advanced Timer Functions Settings that cannot be performed with the DiP switch are performed with the operation keys Power oN For details on operations in run mode, refer to Operation in Timer Function Run Mode Note: 1. If the mode is switched to the functicn setting moce during operation ttings in fur first time when the mode is changed to run mode. Also, when setting are changed the timer is reset time initialized and output turned ol See note 2 (MODE The characters disp ayed in reverse video are the default settings When performing settings with operation keys only set pin 1 of the to ON, the seting items ind:e tting ). If pin 1 of the DIP switch is set DIP switch to OF F (factory settil d in will not be displayed tL∩ Set the time range using the Akeys me rang →--s4----s←---s←b ----h-s For details, refer to Time Range List below Lnn mode Set the timer mode using thea0keys HP Remaining timc) Aurn Set the output mode using the →阳4只-}+阳24月-34b←→b-}4d+E←F Set each digit for the output time using the corresponding (keys Hol d 回+}4已←彐4"45454?4日+9 loLd/0.01-99.99: Output hold/0.01 to 99.99 s VODE (If the output time is set to 0.00, Hoi d is displayed D Sot the input signal width using tho koy Time Range list 2085 →EB54→∶5← Display Set value 0.0′sto99,99s L NPN/PNP gte公 et the NPN/FNP input mode using the 1s to 9,999 s MODE Only displayed for H5 CX-A and H5c×A11口 models. the(公(Ke rEd ←+ (Red) (Cr m o n 01 min to 99 h 59 mi Displayed for torminal-block modols( H5CX-AL)only 0.1hto9999h yyP上| Key protect set the key protect using the a)@ key 1hto9.999h p-! →PP:PP-←PP-34PP-←PP-5← 0.001sto9999s H5CX OmROn H5CX a Explanation of Timer Functions Time Range(ELnr)(Setting possible using DIP switch. Key Protect Level(PyPE) Set the range to be timed in the range 0.000 s to 9, 999 h Settings Set the key protect level of type----h (9, 999 h )and ----min( 9, 999 min) cannot, howe be made with the DIP switch. Use the operation keys if these set When the key-protect switch in set to ON, it is possible to prevent tings are required setting errors by prohibiting the use of certain operation keys by specifying the key protect level( KP-1 to KP-5) the key protect Timer Mode(ELnn)(Setting possible using DIP switch. indicator is lit while the key-protect switch is set to ON. Confirm the ON/OF F status of the key-protect switch after the H5CX is Set either the elapsed time(UP)or remaining time(DOWN) mounted to the panel Output Mode(outn setting possible using DIP switch) (See note)OFF ON Set the output mode. The possible settings are A, A-1,A-2:A- b, b-1, d, E, F, and Z. Only autput mades A, A-2, E, and F can set using the DIP switch Use the operation keys if a different set- ting is required. (For details on output mode operation, refer to Timing Charts. Note: Factory-sel to OFF Output Time(G上Ln Key protect indicator t When using one-shot output, set the output time for one-shot out ut(0.01 to 99.99 s). One-shot output can be used only if the elected output mode is A, A-1, A-2,, or b-1.If the output time set to 0.00, Hol d is displayed and the output is held Level Definitions Input Signal Width(cFLE)(Setting possible using DIP switch) KP-1 Prohibits changing the mode to Set the minimum signal input width(20 ms or 1 ms) for signal, (default timer/twin timer selection mode reset, and gate inputs. The same setting is used for all external setting) mn sc or function setting mode. The H5CX can only be used in run inputs (signal, reset, and gate inputs ) If contacts are used for the mode input signal, set the input signal width to 20 ms Processing to eliminate chattering is performed for this setting KP-2 Prohibits changing the mode to timer/twin timer selection mode NPN/PNP Input Mode(Lnad or function setting mode. The H5CX can only be used in run Select either NPN input (no-voltage input) or PNP input (voltage mode. Also prohibits use of input) as the input format. The same setting is used for all exter the reset key al inputs for details on input connections, refer to input con KP-3 Prohibits changing the mode to nections timer/twin timer selection mode Display Color(CoLr mom cx or function setting mode. The H5CX can only be used in run Set the color used for the present value ode. Also prohibits use of the up and down keys he present value is displayed in red KP-4 Prohibits changing the mode to The present value is displayed in green timer/twin timer selection mode or function setting mode. The The present value is displayed in red when the control H5CX can only be used in run output is OFF and is displayed in green when the mode. Also prohibits use of control output is ON the reset, up and down keys The present value is displayed in green when the KP-5 Prohibits changing the mode to control output is OFF, and is displayed in red when the timer/twin timer selection mode control output is ON or function setting mode The ennen Hic) H5CX can only be used in run Also prol hibits any operation keys 9 H5CX OmRon H5CX Operation in Timer Function Run Mode When Output Mode Is Not Z Present value Set each digit for the set value using the corresponding「公〔 e keys Set value ←;己←3←"←55←"←849 When Output Mode Z Is Selected Present value each digit for the ON duty ratio using the corresponding keys A keys for the 4th digit cannot be used. 日+!↓己←3←4←*5←5←+日49 Present value Sot cach digit for the cyclo timc using thc corrosponding keys ,凵 Cycle time SET 2 Present value and set value These items are displayed when the power is turned oN. The present value is displayed in the main display and the set value is displayed in the sub-display. The values displayed will be deter mined by the settings made for the time range and the timer mode in function setting mode Present value and ON Duty Ratio(Output Mode= z) The present value is displayed in the main display and the on duty ratio is displayed in the sub-display. SET1 lights at the TIMER same time Elapsed Set the on duty ratio used in ON/OFF-duty cycle mode(z)as a percentage on duty set as a percentage If a cycle time is set, cyclic control can be performed in ON/OFF- MOCE duty cycle mode simply by changing the on duty rati Uo/dawn keys used for analog Present Value and Cycle Time (Output Mode=z) adjustment of the on duty omron H5Cx The present value is displayed in the main display and the cycle time is displayed in the sub-display. SET2 " lights at the same Cycle time time Open on duty( % Set the cycle time used in ON/OFF-duty cycle mode(z) Opening/closing vaive I Fuly closed--Fully open ON duty 0%100% 10

...展开详情
试读 32P omron定时器H5CX资料.pdf
立即下载 低至0.43元/次 身份认证VIP会员低至7折
抢沙发
一个资源只可评论一次,评论内容不能少于5个字
weixin_38743506 如果觉得有用,不妨留言支持一下
2019-10-22
  • 至尊王者

    成功上传501个资源即可获取
关注 私信 TA的资源
上传资源赚积分,得勋章
最新推荐
omron定时器H5CX资料.pdf 10积分/C币 立即下载
1/32
omron定时器H5CX资料.pdf第1页
omron定时器H5CX资料.pdf第2页
omron定时器H5CX资料.pdf第3页
omron定时器H5CX资料.pdf第4页
omron定时器H5CX资料.pdf第5页
omron定时器H5CX资料.pdf第6页
omron定时器H5CX资料.pdf第7页

试读结束, 可继续读3页

10积分/C币 立即下载 >