第 42 卷第 3 期
煤 炭 科 学 技 术
Vol 42 No 3
2014 年 3 月
Coal Science and Technology
March 2014
基于瞬变电磁法探测工作面底板含水性研究
陈善乐
1ꎬ2
ꎬ汪华君
1
ꎬ李雨成
2
(1 毕节学院 资源与安全工程学院ꎬ贵州 毕节 551700ꎻ2 辽宁工程技术大学 安全科学与工程学院ꎬ辽宁 阜新 123000)
摘 要:为查明工作面底板岩层主要含水层的含水特性及含水层之间的水力联系ꎬ确保工作面安全回
采ꎬ基于瞬变电磁法探测原理ꎬ利用多匝数小回线测量装置对马坊煤矿 9603 进风巷、9605 东进风巷
的 86 个测点进行探测ꎬ从视电阻率变化、分布规律等方面对水文地质物性条件和含水异常区进行地
质解释ꎬ并利用钻探对探测结果进行了验证ꎮ 结果表明:岩层横向富水性不均一ꎬ呈现分区性ꎬ大部分
块断富水性相对较弱ꎬ只有局部块断富水性相对较强ꎬ研究结果对矿井水害防治具有重要指导意义ꎮ
关键词:底板含水性ꎻ瞬变电磁法ꎻ电阻率ꎻ水害防治
中图分类号:TD74 文献标志码:A 文章编号:0253
-
2336(2014)03
-
0096
-
03
Study on Floor Water
-
Bearing Property of Coal Mining Face
Based on Transient Electromagnetic Method
CHEN Shan ̄le
1ꎬ2
ꎬWANG Hua ̄jun
1
ꎬLI Yu ̄cheng
2
(1.School of Resources and Safety EngineeringꎬBijie UniversityꎬBijie 551700ꎬChinaꎻ
2.School of Safety Science and EngineeringꎬLiaoning Technical UniversityꎬFuxin 123000ꎬChina)
Abstract:In order to find water
-
bearing features of major water bearing layers in the floor strata of the coal mining face and the hydraulic
relationship between the water bearing layers and to ensure the safety mining of the coal mining faceꎬbased on a survey principle of the
mine transient electromagnetic methodꎬa multi turns return wire measuring device was applied to survey 86 measuring points set in No.
9603 air income gateway and No.9605 east air income gateway of Mafang Mine.A geological explanation was conducted on the hydrogeolog ̄
ical physical property condition and the water
-
bearing abnormal zone from the apparent resistivity variationꎬdistribution law and others.The
exploration drillings were applied to verify the survey results.The results showed that a lateral water abundance of the stratum was not ho ̄
mogenizedꎬwas in sectional and the water abundance of the major broken block was relative weak.The water abundance of only partial bro ̄
ken blocks was strong.The study results would have important guidance to the mine water disaster prevention and control.
Key words: floor water
-
bearing propertyꎻtransient electromagnetic methodꎻelectrical resistivityꎻwater disaster prevention and control
收稿日期:2013
-
09
-
23ꎻ责任编辑:杨正凯 DOI:10.13199 / j.cnki.cst.2014.03.026
基金项目:贵州省科学技术基金资助项目(LKB[2012]03)ꎻ贵州省省市共建矿山物探重点实验室资助项目( SSHZ[2012]04)
作者简介:陈善乐(1984—) ꎬ男ꎬ湖南邵阳人ꎬ讲师ꎬ博士研究生ꎮ Tel:18041806522ꎬE
-
mail:lelechen131452@ 163 com
引用格式:陈善乐ꎬ汪华君ꎬ李雨成.基于瞬变电磁法探测工作面底板含水性研究[ J].煤炭科学技术ꎬ2014ꎬ42(3):96
-
98.
CHEN Shan ̄leꎬWANG Hua ̄junꎬLI Yu ̄cheng.Study on Floor Water
-
Bearing Property of Coal Mining Face Based on Transient Electromagnetic
Method[J].Coal Science and Technologyꎬ2014ꎬ42(3) :96
-
98.
0 引 言
矿井突水是威胁煤矿安全生产最主要的灾害之
一ꎬ在我国煤矿重大事故中ꎬ突水事故造成的人员伤
亡和 经 济 损 失 重 大ꎮ 据 不 完 全 统 计ꎬ 2006—2011
年ꎬ我国煤矿共发生水害事故 128 起ꎬ造成 1 101 人
死亡ꎬ经济损失巨大ꎬ其中 2011 年 8 月 19 日ꎬ内蒙
古乌海煤矿透水事故涌水量达 3 000 m
3
ꎮ 因此ꎬ开
展对矿井岩层水、采空区积水的含水特征探测研究
工作尤为重要ꎮ 瞬变电磁法是近年来为了克服矿井
直流电法井下施工受限、电极接地困难而发展起来
的一种新的井下物理探测技术ꎬ具有施工方便快捷、
体积效应小、探测距离大等优点
[1]
ꎮ 在采空区含水
探测
[2
-
3]
、煤层顶底板破坏变形规律
[4
-
6]
、巷道掘进
超前探测
[7
-
8]
等防治水工作中取得了良好的应用效
果ꎮ 随着开采工艺和技术的不断发展ꎬ对巷道和工
作面顶底板岩层的含水性探测精度要求越来越高ꎮ
为了保证工作面正常开采ꎬ在煤层开采之前对工作
69