The standard ADRC controller usually selects the canonical plant in the form of cascaded integrators. However, the condition variables of practical system do not necessarily have the cascaded integral relationship. Therefore, this paper proposes a method of total derivative of composite functions of several variables and a structure, which can convert the state space system of noncascaded integral form into the cascaded integral form. In this way, the converted system can be directly controlled