没有合适的资源?快使用搜索试试~ 我知道了~
IEC TS 61000-5-8-2009.pdf
1.该资源内容由用户上传,如若侵权请联系客服进行举报
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
版权申诉
0 下载量 54 浏览量
2022-07-11
15:05:01
上传
评论
收藏 2.15MB PDF 举报
温馨提示
试读
32页
IEC TS 61000-5-8-2009.pdf
资源推荐
资源详情
资源评论
IEC/TS 61000-5-8
Edition 1.0 2009-08
TECHNICAL
SPECIFICATION
Electromagnetic compatibility (EMC) –
Part 5-8: Installation and mitigation guidelines – HEMP protection methods for
the distributed infrastructure
IEC/TS 61000-5-8:2009(E)
BASIC EMC PUBLICATION
®
colour
inside
Copyright International Electrotechnical Commission
--`````,,,```,,,`,,`,,```,``,-`-`,,`,,`,`,,`---
THIS PUBLICATION IS COPYRIGHT PROTECTED
Copyright © 2009 IEC, Geneva, Switzerland
All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by
any means, electronic or mechanical, including photocopying and microfilm, without permission in writing from either IEC or
IEC's member National Committee in the country of the requester.
If you have any questions about IEC copyright or have an enquiry about obtaining additional rights to this publication,
please contact the address below or your local IEC member National Committee for further information.
Droits de reproduction réservés. Sauf indication contraire, aucune partie de cette publication ne peut être reproduite
ni utilisée sous quelque forme que ce soit et par aucun procédé, électronique ou mécanique, y compris la photocopie
et les microfilms, sans l'accord écrit de la CEI ou du Comité national de la CEI du pays du demandeur.
Si vous avez des questions sur le copyright de la CEI ou si vous désirez obtenir des droits supplémentaires sur cette
publication, utilisez les coordonnées ci-après ou contactez le Comité national de la CEI de votre pays de résidence.
IEC Central Office
3, rue de Varembé
CH-1211 Geneva 20
Switzerland
Email:
inmail@iec.ch
Web:
www.iec.ch
About IEC publications
The technical content of IEC publications is kept under constant review by the IEC. Please make sure that you have the
latest edition, a corrigenda or an amendment might have been published.
Catalogue of IEC publications: www.iec.ch/searchpub
The IEC on-line Catalogue enables you to search by a variety of criteria (reference number, text, technical committee,…).
It also gives information on projects, withdrawn and replaced publications.
IEC Just Published: www.iec.ch/online_news/justpub
Stay up to date on all new IEC publications. Just Published details twice a month all new publications released. Available
on-line and also by email.
Electropedia: www.electropedia.org
The world's leading online dictionary of electronic and electrical terms containing more than 20 000 terms and definitions
in English and French, with equivalent terms in additional languages. Also known as the International Electrotechnical
Vocabulary online.
Customer Service Centre: www.iec.ch/webstore/custserv
If you wish to give us your feedback on this publication or need further assistance, please visit the Customer Service
Centre FAQ or contact us:
Email:
csc@iec.ch
Tel.: +41 22 919 02 11
Fax: +41 22 919 03 00
Copyright International Electrotechnical Commission
--`````,,,```,,,`,,`,,```,``,-`-`,,`,,`,`,,`---
IEC/TS 61000-5-8
Edition 1.0 2009-08
TECHNICAL
SPECIFICATION
Electromagnetic compatibility (EMC) –
Part 5-8: Installation and mitigation guidelines – HEMP protection methods for
the distributed infrastructure
INTERNATIONAL
ELECTROTECHNICAL
COMMISSION
U
ICS 33.100.20
PRICE CODE
ISBN 2-8318-1060-3
BASIC EMC PUBLICATION
® Registered trademark of the International Electrotechnical Commission
®
colour
inside
Copyright International Electrotechnical Commission
--`````,,,```,,,`,,`,,```,``,-`-`,,`,,`,`,,`---
– 2 – 61000-5-8 © IEC:2009(E)
CONTENTS
FOREWORD...........................................................................................................................4
INTRODUCTION.....................................................................................................................6
1 Scope...............................................................................................................................7
2 Normative references .......................................................................................................7
3 Terms and definitions .......................................................................................................8
4 General introduction .......................................................................................................10
5 Description of the distributed infrastructure ....................................................................10
6 Spatial variation of HEMP environments .........................................................................11
6.1 Early-time (E1) HEMP spatial variations ................................................................11
6.2 Intermediate-time (E2) HEMP spatial variations.....................................................13
6.3 Late-time (E3) HEMP spatial variations .................................................................13
7 Implications for HEMP coupling to extended conductors ................................................. 13
7.1 General .................................................................................................................13
7.2 Early-time (E1) conducted environments ...............................................................13
7.3 Intermediate-time (E2) conducted environments ....................................................14
7.4 Late-time (E3) conducted environments ................................................................15
8 Relation of HEMP disturbances to natural EM environments...........................................16
8.1 General .................................................................................................................16
8.2 Comparison of HEMP E1 to EFT and surge ...........................................................16
8.3 Comparison of HEMP E3 to currents induced by geomagnetic storms ...................17
9 Protection strategy .........................................................................................................18
9.1 General .................................................................................................................18
9.2 Electric power .......................................................................................................18
9.2.1 Background ...............................................................................................18
9.2.2 Emergency planning, operating procedures and restoration.......................20
9.2.3 HEMP immunity standards for new equipment ...........................................20
9.2.4 Selected retrofit protection.........................................................................21
9.2.5 Application to a high-voltage power substation ..........................................22
9.3 Telecommunication centres ...................................................................................25
9.4 Other infrastructures .............................................................................................25
Bibliography..........................................................................................................................26
Figure 1 – Simplified depiction of the interdependency of critical infrastructures [4] ..............
11
Figure 2 – E1 HEMP tangent radius as a function of the height of burst ................................12
Figure 3 – An example of the area covered by the early-time (E1) HEMP by a 170 km
burst over the United States .................................................................................................
12
Figure 4 – Late-time (E3) electric field waveform from IEC 61000-2-9...................................17
Figure 5 – Vertical conduit geometry for a current transformer (CT) ......................................23
Figure 6 – Covered shallow trench for control cables ............................................................23
Figure 7 – Grounding of control cables at junction box..........................................................24
Figure 8 – Control cable access to equipment.......................................................................24
Table 1 – Peak currents induced by the E1 HEMP on above-ground and buried
conductors ............................................................................................................................
14
Copyright International Electrotechnical Commission
--`````,,,```,,,`,,`,,```,``,-`-`,,`,,`,`,,`---
61000-5-8 © IEC:2009(E) – 3 –
Table 2 – Peak currents induced by the E2 HEMP on above-ground and buried
conductors ............................................................................................................................
15
Table 3 – Minimum required attenuation of peak time domain external environments for
the six principal protection concepts .....................................................................................
21
Copyright International Electrotechnical Commission
--`````,,,```,,,`,,`,,```,``,-`-`,,`,,`,`,,`---
剩余31页未读,继续阅读
资源评论
std86021
- 粉丝: 93
- 资源: 2691
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功