METRIC
MIL-STD-1275B
20 November 1997
SUPERSEDING
MIL-STD-1275A(AT)
17 September 1976
DEPARTMENT OF DEFENSE
INTERFACE STANDARD
CHARACTERISTICS OF 28 VOLT DC
ELECTRICAL SYSTEMS IN
MILITARY VEHICLES
AMSC N/A FSC 2920
DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited.
Downloaded from http://www.everyspec.com
MIL-STD-1275B
ii
FOREWORD
1. This standard is approved for use by all departments and agencies of the Department of
Defense.
2. The intent of this document is to provide a standard limiting voltage characteristics of 28 volt
direct current (dc) electric circuits on military vehicles.
3. Beneficial comments (recommendations, additions, deletions) and any pertinent data which
may be of use in improving this document should be addressed to: U.S. Army Tank-automotive
and Armaments Command, ATTN: AMSTA-TR-E/BLUE, Warren, MI 48397-5000, by using
the Standardization Document Improvement Proposal (DD Form 1426) appearing at the end of
this document or by letter.
Downloaded from http://www.everyspec.com
MIL-STD-1275B
iii
CONTENTS
PARAGRAPH PAGE
FOREWORD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii
1. SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
1.1 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2. APPLICABLE DOCUMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2 Government documents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
2.2.1 Specifications, standards, and handbooks . . . . . . . . . . . . . . . . . . . . . . . . 1
2.3 Order of precedence . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
3. DEFINITIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.1 Vehicle power supply system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.2 Fault . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.3 Transients . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.3.1 Surge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.3.2 Spike . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.4 Steady-state . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.5 Recovery time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
3.1.6 Ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3.1.7 Starting disturbances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. GENERAL REQUIREMENTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.1 Temperature conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.2 Circuit characteristics point of measurement. . . . . . . . . . . . . . . . . . . . . . 6
4.3 Equipment compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
4.4 Polarity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5. DETAILED REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1 Fault free condition . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.1 Electromagnetic interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.2 Combined generator-battery power supply . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.2.1 Steady-state voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.2.2 Ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.2.3 Surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
5.1.2.4 Spikes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5.1.2.5 Starting disturbances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5.1.2.5.1 Initial engagement surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.2.5.2 Cranking level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Downloaded from http://www.everyspec.com
MIL-STD-1275B
iv
CONTENTS
PARAGRAPH PAGE
5.1.3 Battery only condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.1 Steady-state voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.2 Ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.3 Surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.4 Spikes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.5 Starting disturbances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.5.1 Initial engagement surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1.3.5.2 Cranking level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2 Single fault condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.1 Steady-state voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.2 Ripple . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.3 Surges . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.2.4 Spikes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
5.3 Compatibility of power supply system and utilization equipment . . . . . 11
5.4 Test methods . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.4.1 Vehicle electrical system. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.4.2 Vehicle equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.4.2.1 General. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.4.2.2 Spikes exported from equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
5.4.2.3 Spikes exported into equipment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
5.4.2.4 Voltage surges imported into equipment. . . . . . . . . . . . . . . . . . . . . . . 15
6. NOTES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.1 Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.2 Subject term (key word) listing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
6.3 International interest . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
FIGURES
1. Illustrative surge with recovery time . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
2. Enlarged view of ripple. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
3. Starting disturbances . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
4. Loci of surges fault free condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
5. Loci of spikes fault free condition. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
6. Loci of surges single fault condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
7. Loci of spikes single fault condition . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
8. Exported spike test circuit (all equipment) . . . . . . . . . . . . . . . . . . . . . . . 13
9. Exported spike test circuit (equipment with remote switch) . . . . . . . . . . 13
10. Imported spike test circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
11. Imported surge test circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Downloaded from http://www.everyspec.com
MIL-STD-1275B
1
1. SCOPE
1.1 Scope. This standard covers the limits of transient voltage characteristics and steady
state limits of the 28 volt (V) direct current (dc) electric power circuits of military vehicles.
2. APPLICABLE DOCUMENTS
2.1 General. The documents listed in this section are specified in sections 3, 4 and 5 of
this standard. This section does not include documents cited in other sections of this standard or
recommended for additional information or as examples. While every effort has been made to
ensure the completeness of this list, document users are cautioned that they must meet all
specified requirement documents cited in sections 3, 4 and 5 of this standard, whether or not they
are listed.
2.2 Government documents.
2.2.1 Specifications, standards, and handbooks. The following specifications, standards,
and handbooks form a part of this document to the extent specified herein. Unless otherwise
specified, the issues of these documents are those listed in the issue of the Department of Defense
Index of Specifications and Standards (DoDISS) and supplement thereto, cited in the solicitation.
STANDARDS
DEPARTMENT OF DEFENSE
MIL-STD-461 - Electromagnetic Interference Characteristics
Requirements for Equipment.
(Unless otherwise indicated, copies of the above specifications, standards, and handbooks
are available from the Standardization Document Order Desk, 700 Robbins Avenue, Building 4D,
Philadelphia, PA 19111-5094.)
2.3 Order of precedence. In the event of a conflict between the text of this document
and the references cited herein, the text of this document takes precedence. Nothing in this
document, however, supersedes applicable laws and regulations unless a specific exemption has
been obtained.
Downloaded from http://www.everyspec.com