没有合适的资源?快使用搜索试试~ 我知道了~
ROTEL路遥RB-1552 MkII 使用说明书.pdf
1.该资源内容由用户上传,如若侵权请联系客服进行举报
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
版权申诉
0 下载量 77 浏览量
2023-02-13
09:47:04
上传
评论
收藏 3.35MB PDF 举报
温馨提示
试读
20页
ROTEL路遥品牌说明书
资源推荐
资源详情
资源评论
Owner’s Manual
使用说明书
RB-1552MKII / RB-1582MKII
Stereo Power Amplifiers
立体声后置放大器
RB-1582MKII
2
RB-1552MKII/RB-1582MKII Stereo Power Amplifiers
WARNING: There are no user serviceable parts inside. Refer all
servicing to qualified service personnel.
WARNING: To reduce the risk of fire or electric shock, do not expose
the unit to moisture or water. Do not expose the unit to dripping or
splashing. Do not place objects filled with liquids, such as vases, on
the unit. Do not allow foreign objects to get into the enclosure. If the
unit is exposed to moisture, or a foreign object gets into the enclosure,
immediately disconnect the power cord from the wall. Take the unit
to a qualified service person for inspection and necessary repairs.
Read all the instructions before connecting or operating the component.
Keep this manual so you can refer to these safety instructions.
Heed all warnings and safety information in these instructions and on
the product itself. Follow all operating instructions.
Clean the enclosure only with a dry cloth or a vacuum cleaner.
Do not use this unit near water.
You must allow a minimum 10 cm or 4 inches of unobstructed
clearance around the unit.
Do not place the unit on a bed, sofa, rug, or similar surface that could
block the ventilation openings. If the unit is placed in a bookcase or
cabinet, there must be ventilation of the cabinet to allow proper cooling.
Keep the component away from radiators, heat registers, stoves, or
any other appliance that produces heat.
Rotel products are designed to comply with
international directives on the Restriction of
Hazardous Substances (RoHS) in electrical and
electronic equipment and the disposal of Waste
Electrical and Electronic Equipment (WEEE). The
crossed wheelie bin symbol indicates compliance
and that the products must be appropriately recycled
or processed in accordance with these directives.
Important Safety Instructions
WARNING: The rear panel power cord connector is the mains power
disconnect device. The device must be located in an open area that
allows access to the cord connector.
The unit must be connected to a power supply only of the type
and voltage specified on the rear panel. (USA: 120 V/60Hz,
EC: 230V/50Hz)
Connect the component to the power outlet only with the supplied
power supply cable or an exact equivalent. Do not modify the
supplied cable. A polarized plug has two blades, with one wider than
the other. A grounding plug has two blades plus a third grounding
prong. These are provided for your safety. Do not defeat grounding
and/or polarization safety provisions. If the supplied plug does not
fit your outlet, please consult an electrician for replacement of the
obsolete outlet. Do not use extension cords.
The main plug of the power cordset is a disconnect device of the
apparatus. In order to completely disconnect the apparatus from
the supply mains, the main plug of the power cordset should be
unplugged from the mains (AC) outlet. The stand-by LED indicator
will not be lit up to show the power cord is unplugged. The disconnect
device shall remain readily operable.
Do not route the power cord where it will be crushed, pinched, bent,
exposed to heat, or damaged in any way. Pay particular attention to the
power cord at the plug and where the cord exits the back of the unit.
The power cord should be unplugged from the wall outlet during a
lightning storm or if the unit is to be left unused for a long period
of time.
This apparatus shall be connected to a main socket outlet with a
protective earth connection.
Use only accessories specified by the manufacturer.
Use only with a cart, stand, rack, bracket or shelf
system recommended by Rotel. Use caution when
moving the unit in a stand or rack to avoid injury
from a tip-over.
Use Class 2 wiring for speaker connections to ensure proper insulation
and minimize the risk of electric shock.
Immediately stop using the component and have it inspected and/
or serviced by a qualified service agency if:
• The power supply cord or plug has been damaged.
• Objects have fallen or liquid has been spilled into the unit.
• The unit has been exposed to rain.
• The unit shows signs of improper operation.
• The unit has been dropped or damaged in any way.
RB-1582MKII
For RB-1552MKII only:
This symbol means that this unit is double insulated.
An earth connection is not required.
1
2
3
Pin Assignments
Balanced Audio (3 pole XLR):
Pin 1: Ground / Screen
Pin 2: In phase / +ve / Hot
Pin 3: Out of phase / -ve / Cold
3
Figure 1: Controls and Connections
SPEAKERS
RB-1582MKII
RB-1552MKII
RB-1552MKII
1
2
3 4
6 7 6 8
3
46 6
7 7 8
9
5
5
4
RB-1552MKII/RB-1582MKII Stereo Power Amplifiers
Figure 2: Analog Inputs and Speaker Output Connections
PREAMPLIFIER
SPEAKERSPEAKER
SPEAKERSPEAKER
RB-1552MKII
RB-1582MKII
SPEAKERS
剩余19页未读,继续阅读
资源评论
qingguo1979
- 粉丝: 28
- 资源: 7296
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
- CAN总线的理论分析报告
- Screenshot_2024_0614_022736.png
- update_new.apk
- 如何将keil5中的bin文件合并
- 基于Selenium的Java爬虫实战(内含谷歌浏览器Chrom和Chromedriver版本122.0.6254.0)
- CAN波特率为100kbps时分支线长度
- 74LS90实现十进制计数器、百进制计数器-multisim电路仿真设计
- 基于Selenium的Java爬虫实战(内含谷歌浏览器Chrom和Chromedriver版本122.0.6253.0)
- this is incompatible with sql-mode=only-full-group-by
- YOLO损坏的苹果检测数据集【目标检测数据集】
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功