Recommendation V.24 (10/96) 1
Recommendation V.24
Recommendation V.24 (10/96)
LIST OF DEFINITIONS FOR INTERCHANGE CIRCUITS
BETWEEN DATA TERMINAL EQUIPMENT (DTE)
AND DATA CIRCUIT-TERMINATING EQUIPMENT (DCE)
(Geneva, 1964, amended at Mar del Plata, 1968, Geneva, 1972, 1976 and 1980,
Malaga-Torremolinos, 1984, Melbourne, 1988, Helsinki, 1993, and Geneva 1996)
1 Scope
1.1 This Recommendation applies to the interconnecting circuits being called interchange circuits at the interface
between DTE and DCE for the transfer of binary data, control and timing signals and analogue signals as appropriate.
This Recommendation also applies to both sides of separate intermediate equipment, which may be inserted between
these two classes of equipment (see Figure 1).
T1400030-93/d01
AB
C
DTE
DCE
Line of demarcation
V.24 interface
V.24 interface
NOTE – Without intermediate equipment the selections A and B are identical.
Selection C may be a selection specifically for automatic calling.
Line
FIGURE 1/V.24
Illustration of general layout of equipment
Intermediate
equipment
(e.g. error control)
FIGURE 1/V.24...[D01] = 8 CM
Electrical characteristics for interchange circuits are detailed in appropriate Recommendations for electrical charac-
teristics, or in certain special cases, in Recommendations for DCE.
In any type of practical equipment a selection will be made from the range of interchange circuits defined in this
Recommendation, as appropriate.
The actual interchange circuits to be used in a particular DCE are those indicated in the appropriate Recommendation.
The required interchange circuits specified in the DCE Recommendations which make reference to this
Recommendation apply only to the DCE side of the interface. Only those circuits necessary to assure satisfactory
operation of the application the DTE is intending to support need be controlled or monitored by the DTE. (See Note
to 3.4 for proper handling of unimplemented circuits).
The usage and operational requirements of the interchange circuits and the interaction between them are recommended
in clause 4. For proper operation of the DCE it is important that the guidelines in clause 4 be observed.