没有合适的资源?快使用搜索试试~ 我知道了~
ABB伺服驱动器-MicroFlex-e190-快速安装指南-MFE190-04UD.pdf
1.该资源内容由用户上传,如若侵权请联系客服进行举报
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
版权申诉
0 下载量 22 浏览量
2024-04-26
12:50:43
上传
评论
收藏 1.34MB PDF 举报
温馨提示
试读
20页
ABB伺服驱动器_MicroFlex_e190_快速安装指南_MFE190-04UD
资源推荐
资源详情
资源评论
—
List of related manuals
You can find manuals and other product documents in PDF format on the Internet. See
section
Document library on the Internet on the inside of the back cover. For manuals not
available in the Document library, contact your local ABB representative.
Drive hardware manuals and guides Code (English)
MicroFlex e190 User’s manual 3AXD50000037326
MicroFlex e190 Wall chart 3AXD50000037323
Certificates
MicroFlex e190 EU Single Declaration of Conformity 3AXD10001229164
MicroFlex e190 STO (TÜV) Certificate 3AXD10001229165
MicroFlex e190 UL Certificate 3AXD10001251067
Option manuals and guides
OPT-MF-200 Encoder Breakout Quick installation guide 3AXD10000692233
OPT-MF-201 Resolver Adapter Quick installation guide 3AXD10000688314
OPT-SIO-1 Option Card User's manual 3AXD50000351336
OPT-SIO-1 Option Card Quick installation guide 3AXD50000296361
3AXD50000037325 Rev E
MUL
EFFECTIVE: 2021-04-30
Quick installation guide - MicroFlex e190
3
Quick installation guide -
MicroFlex e190
Introduction
This guide contains the information about
the mechanical and electrical installation of
the MicroFlex e190 drive module. For
complete documentation see the
MicroFlex e190 User’s Manual (code:
3AXD50000037326).
Safety instructions
WARNING! All electrical
installation and maintenance work
on the drive should be carried out
by qualified electricians only.
WARNING! Obey the safety
instructions. If you ignore them,
injury or death, or damage to the
equipment can occur.
WARNING! Operation of this
equipment requires detailed
installation and operation
instructions provided in the
Installation/Operation manual intended for
use with this product. It should be retained
with this device at all times.
Never work on the drive, the braking
chopper circuit, the motor cable or the
motor when input power is applied to the
drive. After disconnecting input power,
always wait for 5 minutes to let the
intermediate circuit capacitors discharge
before you start working on the drive,
control cabling, motor or motor cable. Even
when input power is not applied to the
drive, externally supplied control circuits
may carry dangerous voltages. Always
ensure by measuring that no voltage is
actually present.
• A rotating permanent magnet motor can
generate a dangerous voltage. Lock the
motor shaft mechanically before
connecting a permanent magnet motor to
the drive, and before doing any work on a
drive system connected to a permanent
magnet motor.
• The MicroFlex e190 is an IP20 (open type)
drive to be used in a heated, indoor
controlled environment. The drive must
be installed in clean air according to
enclosure classification. Cooling air must
be clean, free from corrosive materials
and electrically conductive dust. See the
User’s Manual for detailed specifications.
• The MicroFlex e190 must be installed
where the pollution degree according to
UL and EN 61800-5-1 shall not exceed 2.
• The maximum ambient air temperature is
55 °C (131 °F) at rated current. No current
derating is required.
• The drive is suitable for use in a circuit
capable of delivering not more than
5,000A (rms) symmetrical amperes, 240 V
maximum, when protected by fuses rated
max. 20 A.
• The cables located within the motor
circuit must be rated for at least 75 °C
(167 °F) in UL-compliant installations.
• Use copper wiring only.
• The input cable must be protected with
fuses. Suitable gG (IEC) and CC (UL) fuses
are listed in the Technical data section of
the MicroFlex e190 User’s Manual
.
• Integral solid state short circuit
protection does not provide branch
circuit protection. For installation in the
United States, branch circuit protection
must be provided in accordance with the
National Electrical Code (NEC) and any
applicable local codes. To fulfill this
requirement, use the UL classified fuses.
Quick installation guide - MicroFlex e190
4
• For installation in Canada, branch circuit
protection must be provided in
accordance with Canadian Electrical Code
and any applicable provincial codes. To
fulfill this requirement, use the UL
classified fuses.
• For use in Canada: Transient surge
suppression shall be installed on the line
side of this equipment and shall be rated
240 V (phase to ground), 240 V (phase to
phase), suitable for overvoltage category
III, and shall provide protection for a rated
impulse withstand voltage peak of 2.5 kV.
• The drive provides overload protection in
accordance with the National Electrical
Code (NEC). See the
User’s Manual for
overload protection settings.
• The drive can provide an overload current
of 300% of rated current for a maximum
of 3 s. See User’s Manual.
• The drive must be installed within an area
which does not allow unauthorized
access, such as a cabinet with a lock or
that is accessible only by a special tool.
• The communication cables between the
drive and other devices must be
connected within an area which does not
allow unauthorized access, such as a
cabinet with a lock or that is accessible
only by a special tool.
• It is recommended to use ABB specified
communication cables in accordance with
CE and UL safety requirements.
• The memory unit can be fixed on the drive
securely with the supplied screw for
safety. It is not allowed to remove and
insert the memory unit while the drive is
running.
• The memory unit’s installation slot is
designed for the memory unit matching
the same drives type only, other modules
cannot be inserted.
Mechanical installation
Fasten the drive module to the mounting
surface using screws through the two
mounting holes.
剩余19页未读,继续阅读
资源评论
AAA_自动化工程师
- 粉丝: 6108
- 资源: 3360
下载权益
C知道特权
VIP文章
课程特权
开通VIP
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功