<?xml version="1.0" encoding="iso-8859-1"?>
<!-- Created by: Martin.Diez@BURKERT +++ Tool: Communicator 6.2.3.0 -->
<!-- Configuration Version: 1.0 -->
<ISO15745Profile xmlns="http://www.profibus.com/GSDML/2003/11/DeviceProfile" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.profibus.com/GSDML/2003/11/DeviceProfile ..\xsd\GSDML-DeviceProfile-v2.32.xsd">
<ProfileHeader>
<ProfileIdentification>PROFINET Device Profile</ProfileIdentification>
<ProfileRevision>1.00</ProfileRevision>
<ProfileName>Device Profile for PROFINET Devices</ProfileName>
<ProfileSource>PROFIBUS Nutzerorganisation e. V. (PNO)</ProfileSource>
<ProfileClassID>Device</ProfileClassID>
<ISO15745Reference>
<ISO15745Part>4</ISO15745Part>
<ISO15745Edition>1</ISO15745Edition>
<ProfileTechnology>GSDML</ProfileTechnology>
</ISO15745Reference>
</ProfileHeader>
<ProfileBody>
<DeviceIdentity VendorID="0x0078" DeviceID="0x23">
<InfoText TextId="IDT_FAMILY_DESCRIPTION" />
<VendorName Value="buerkert fluid control systems" />
</DeviceIdentity>
<DeviceFunction>
<Family MainFamily="Gateway" ProductFamily="Gateway" />
</DeviceFunction>
<ApplicationProcess>
<DeviceAccessPointList>
<DeviceAccessPointItem ID="ID_DAP_BUERKERT" ModuleIdentNumber="0x100" PNIO_Version="V2.32" PhysicalSlots="0..10" MinDeviceInterval="128" ImplementationType="ASIC" DNS_CompatibleName="Batch" FixedInSlots="0" ObjectUUID_LocalIndex="1" RequiredSchemaVersion="V2.1" MultipleWriteSupported="true" MaxSupportedRecordSize="4068" ParameterizationSpeedupSupported="false" NameOfStationNotTransferable="true" SharedDeviceSupported="true" DeviceAccessSupported="true" CheckDeviceID_Allowed="true" LLDP_NoD_Supported="true" ResetToFactoryModes="2">
<ModuleInfo>
<Name TextId="IDT_DAP_RTEM_NAME" />
<InfoText TextId="IDT_DAP_RTEM_INFO" />
<VendorName Value="buerkert fluid control systems" />
<OrderNumber Value="65000" />
</ModuleInfo>
<CertificationInfo ConformanceClass="B" ApplicationClass="" NetloadClass="III" />
<SubslotList>
<SubslotItem SubslotNumber="32768" TextId="IDT_Interface" />
<SubslotItem SubslotNumber="32769" TextId="IDT_Port1" />
<SubslotItem SubslotNumber="32770" TextId="IDT_Port2" />
</SubslotList>
<IOConfigData MaxInputLength="1440" MaxOutputLength="1440" />
<UseableModules>
<ModuleItemRef ModuleItemTarget="BatchControl (Slot 1)" FixedInSlots="1" />
<ModuleItemRef ModuleItemTarget="ManualTargetVolume (Slot 2)" FixedInSlots="2" />
<ModuleItemRef ModuleItemTarget="Totalizer (Slot 3)" FixedInSlots="3" />
<ModuleItemRef ModuleItemTarget="Flow (Slot 4)" FixedInSlots="4" />
<ModuleItemRef ModuleItemTarget="BatchState (Slot 5)" FixedInSlots="5" />
<ModuleItemRef ModuleItemTarget="BatchErrorState (Slot 6)" FixedInSlots="6" />
<ModuleItemRef ModuleItemTarget="ValveStateBinary (Slot 7)" FixedInSlots="7" />
<ModuleItemRef ModuleItemTarget="ValveStateProportional (Slot 8)" FixedInSlots="8" />
<ModuleItemRef ModuleItemTarget="Device Status NamurNe107 (Slot 9)" FixedInSlots="9" />
<ModuleItemRef ModuleItemTarget="Control Word (Slot 10)" FixedInSlots="10" />
</UseableModules>
<VirtualSubmoduleList>
<VirtualSubmoduleItem ID="IDS_SUBMODULE_ParameterTelegram" SubmoduleIdentNumber="0x00001000" Writeable_IM_Records="1 2 3 4" FixedInSubslots="1" MayIssueProcessAlarm="false">
<IOData IOPS_Length="1" IOCS_Length="1" />
<RecordDataList>
<ParameterRecordDataItem Index="7" Length="4">
<Name TextId="Control_Mode" />
<Ref ValueItemTarget="Control_Mode" ByteOffset="0" DataType="Unsigned32" TextId="Control_Mode" DefaultValue="1" />
</ParameterRecordDataItem>
<ParameterRecordDataItem Index="20" Length="2">
<Name TextId="Diagnose_Type" />
<Ref ValueItemTarget="Diagnose_Type" ByteOffset="0" DataType="Unsigned16" TextId="Diagnose_Type" DefaultValue="0" />
</ParameterRecordDataItem>
</RecordDataList>
<ModuleInfo>
<Name TextId="ConfigParam" />
<InfoText TextId="ConfigParam" />
</ModuleInfo>
</VirtualSubmoduleItem>
</VirtualSubmoduleList>
<SystemDefinedSubmoduleList>
<InterfaceSubmoduleItem ID="DaP10" SubmoduleIdentNumber="0x00001001" TextId="IDT_DAP_RTEM_INTERFACE" SubslotNumber="32768" SupportedRT_Classes="RT_CLASS_1" SupportedProtocols="SNMP;LLDP" SupportedMibs="MIB2" PTP_BoundarySupported="true" DCP_BoundarySupported="true">
<ApplicationRelations StartupMode="Legacy;Advanced" NumberOfAR="2">
<TimingProperties SendClock="32" ReductionRatio="1 2 4 8 16 32 64 128 256 512" />
</ApplicationRelations>
<MediaRedundancy SupportedRole="Client" />
</InterfaceSubmoduleItem>
<PortSubmoduleItem ID="DaP11" SubmoduleIdentNumber="0x00001002" MAUTypes="16" PortDeactivationSupported="true" IsDefaultRingport="true" SubslotNumber="32769" TextId="IDT_ETHERNETINTERFACE_Port1">
<MAUTypeList>
<MAUTypeItem Value="16" AdjustSupported="true" />
</MAUTypeList>
</PortSubmoduleItem>
<PortSubmoduleItem ID="DaP12" SubmoduleIdentNumber="0x00001003" MAUTypes="16" PortDeactivationSupported="true" IsDefaultRingport="true" SubslotNumber="32770" TextId="IDT_ETHERNETINTERFACE_Port2">
<MAUTypeList>
<MAUTypeItem Value="16" AdjustSupported="true" />
</MAUTypeList>
</PortSubmoduleItem>
</SystemDefinedSubmoduleList>
<Graphics>
<GraphicItemRef Type="DeviceSymbol" GraphicItemTarget="1" />
</Graphics>
</DeviceAccessPointItem>
</DeviceAccessPointList>
<ModuleList>
<ModuleItem ID="BatchControl (Slot 1)" ModuleIdentNumber="0x00000201">
<ModuleInfo CategoryRef="Output Module">
<Name TextId="BatchControl (Slot 1)_NAME" />
<InfoText TextId="BatchControl (Slot 1)_INFO" />
</ModuleInfo>
<VirtualSubmoduleList>
<VirtualSubmoduleItem ID="IDS_Slot1_BatchControl (Slot 1)" SubmoduleIdentNumber="0x00000001" FixedInSubslots="1" MayIssueProcessAlarm="false">
<IOData>
<Output>
<DataItem DataType="Unsigned8" UseAsBits="false" TextId="IDT_DATAITEM_BatchControl (Slot 1)" />
</Output>
</IOData>
<ModuleInfo>
<Name TextId="BatchControl (Subslot 1)_NAME" />
<InfoText TextId="BatchControl (Subslot 1)_INFO" />
</ModuleInfo>
</VirtualSubmoduleItem>
</VirtualSubmoduleList>
</ModuleItem>
<ModuleItem ID="ManualTargetVolume (Slot 2)" ModuleIdentNumber="0x00000202">
<ModuleInfo CategoryRef="Output Module">
<Name TextId="ManualTargetVolume (Slot 2)_NAME" />
<InfoText TextId="ManualTargetVolume (Slot 2)_INFO" />
</ModuleInfo>
<VirtualSubmoduleList>
<VirtualSubmoduleItem ID="IDS_Slot2_ManualTargetVolume (Slot 2)" SubmoduleIdentNumber="0x00000001" FixedInSubslots="1" MayIssueProcessAlarm="false">
<IOData>
<Output>
<DataItem DataType="Float32" UseAsBits="false" TextId="IDT_DATAITEM_ManualTargetVolume (Slot 2)" />
</Output>
</IOData>
<Module