没有合适的资源?快使用搜索试试~ 我知道了~
温馨提示
试读
96页
顿防爆电气 您可信赖的安全 为恶劣危险环境提供全球领先的防爆电气产品解决方案 伊顿防爆电气(Eaton’s Crouse-Hinds )是伊顿旗下事业部之一,成立于1897年,总部位于美国纽约州锡拉丘兹市。 我们的产品广泛应用于石油与天然气、船舶与海洋工程、石油化工、矿井、能源产业、饮食制药业和其它恶劣工业环境及机场等民航领域,主要涉及产品: 防爆、工业和船用照明灯具 防爆接线箱及配电系统 电气元器件和过程控制保护设备 插头插座及连接器 管件和电缆管理解决方案 MTL仪器仪表 信号、报警、通讯和监控设备 机场照明系统等 伊顿防爆电气在中国、美国、英国、德国和西班牙等多个国家和地区都有生产和研发基地,销售和技术服务团队遍布全球多个国家和地区的主要城市。致力于中国市场的开发和投资, 中国常州工厂于2012年建成投产,大大加速了产品的本土化和交货周期,为中国市场、亚太市场及全球市场供应全系列的防爆电气产品。 伊顿(Eaton)于2012年收购整个库柏工业集团(Cooper Industries)。收购后,原CooperCrouse-Hinds 改称为Eaton’sCrouse-Hinds
资源推荐
资源详情
资源评论
Apparatus
Section A
Innovative, intelligent NEC and IEC solutions safely and efficiently control power
and protect circuits in explosive, wet, and corrosive environments worldwide.
Notable changes to the Apparatus section of this catalog
• Surge Protection Devices (previously section 4A) has been removed. For information on surge protection, please visit
Eaton's Crouse-Hinds MTL Instruments at www.mtl-inst.com
• New Section 4A for transformers
New Products in the Apparatus Product Line Section
• SynergEX Panelboards 1A
• EID Disconnect Assembly (Fused) 2A
• XDT Explosionproof Dry-Type Transformers 4A
EATON 授权经销商 华微科技(天津)有限公司
丁先生 18622336331
EATON cooper crouse hinds MEDC CEAG CAPRI 防爆电气系列
A
624
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
A
Apparatus
Table of Contents
Section A of the Eaton's Crouse-Hinds catalog contains the following product groupings:
Section 2A
Switches
(for use in hazardous and non-hazardous areas)
Switches and enclosures for disconnecting motor, lighting and other
circuits.
EDS, EDSC
FSPC
NST
EFD, EFDC
GUSC
NRS
FLS
WST
6810 Series
EID
GHG
7810 Series
EBM
N2RS
Section 3A
Instrument Housings
(for use in hazardous areas)
Housings for a variety of types and makes of meters and
instruments, thermostats, heaters and clocks.
HRC ETW
TCH ETC
EXH ETR
XC D2TW
Section 1A
Panelboards
(for use in hazardous and non-hazardous areas)
For central control and protection of a large number of feeder or
branch circuits and for housing of circuit breakers.
D2L XLPB
D2PB EXD
D2D GUSC
EPL D2Z
LP N2PB
SPB NLP
Section 4A
Transformers
Provide safe and efficient electric power distribution in the
most extreme harsh and hazardous locations.
XDT
EATON 授权经销商 华微科技(天津)有限公司
丁先生 18622336331
1A
625
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
1A
Panelboards
Hazardous and Non-hazardous
Description Page No.
General Information
see page 626
Application/Selection
see page 627
Wiring Diagrams
see page 628
Hazardous Location Panelboards
Division 1 and 2
PowerPlus™ EXD
see page 641
PowerPlus™ EPL
see page 634
SynergEX SPB
see pages 650–653
Exactra™ LP
see page 630
GUSC
see pages 667–668
Division 2
PowerPlus™ D2D
see page 641
PowerPlus™ D2L
see page 634
Exactra™ LP
see page 630
D2PB
see page 663
N2PB
see pages 669–671
GUSC
see pages 667–668
D2Z
see page 654
Ordinary Location
XLPB
see page 672
NLP Series
see page 675
EATON 授权经销商 华微科技(天津)有限公司
丁先生 18622336331
1A
626
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
1A
Circuit Breaker Panelboards
General Information
Applications:
Circuit breaker panelboards are used in
hazardous and non-hazardous areas (as
shown in the individual listings):
• To provide, in one compact unit, a
centrally controlled switching system for
a large number of feeder or branch
circuits
• For controlling lighting, heating,
appliance, heat tracing, motor and
similar circuits
• In locations where rough usage,
moisture, dust, dirt and corrosion are a
problem
• To house thermal-magnetic circuit
breakers that provide disconnect means,
short circuit protection and thermal time
delay overload protection
Features:
Panelboards:
• All main and branch circuit wire lugs are
solderless and readily accessible for
fast, easy installation
• Are factory wired from main terminal
blocks or main bus to line side of branch
circuit breakers
• With circuit breakers in factory sealed
housings (LP1, EXD and EPL), are also
factory wired from the load side of
branch circuit breakers to readily
accessible terminal blocks
• With circuit breakers grouped in one
enclosure (LP2, D2D, D2L, D2Z and
D2PB factory sealed), branch circuit
wires are attached directly to circuit
breaker load terminals
Circuit breakers (thermal magnetic):
• Are trip-free of the handles and cannot
be held closed under short circuit or
overload conditions
• Four breaker types are used in
panelboards manufactured by Eaton's
Crouse-Hinds. They are as follows:
• Quicklag
®
– used in LP, D2PB, EPL and
D2L panelboards; 10,000 ampere
symmetrical interrupting capacity
Ratings Fed. Spec.
Single and two-pole,
120 / 240 VAC
W-C-375a, Class 1a
Two and three-pole,
240 VAC
W-C-375a, Class 1b
• EHD/FDB frame – used in EXD and D2D
panelboards; 14,000 ampere
symmetrical interrupting capacity
- 480 VAC
Ratings Fed. Spec.
Single-pole, 277 VAC
or 125 VDC
W-C-375a, Class 2a
Two and three-pole
480 VAC or 250 VDC
N/A
Wiring Systems:
• See pages 628 and 629 for wiring
diagrams. These are the standard
systems used for single and three-phase
panelboards having single, two and
three-pole circuit breakers
• Standard panelboards are listed with all
circuit breakers having the same number
of poles and wired for one of these
systems
• To meet the requirements of a specific
installation, panelboards can be
assembled with a combination of single,
two and three-pole breakers. To
accomplish this, the three individual
wiring systems must have the same
main service as, for example, 3-phase,
4-wire, solid neutral.
Panelboard Type
Applicable
Wiring
Systems
D2PB
3, 4, 5, 8, 11, 12
• Diagrams show only four, six or eight
circuits; are intended to show only the
phase connections of each circuit
breaker and do not necessarily show
their physical location in a panelboard.
Panelboards are available with the number
of circuits indicated in the listings.
Standard Materials,
Finishes, Options and
Compliances:
• See individual listing pages
Quicklag is a registered trademark of Cutler-Hammer Inc.
EATON 授权经销商 华微科技(天津)有限公司
丁先生 18622336331
1A
627
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
1A
Circuit Breaker Panelboards
Quick Selector Chart
Quick Selector Chart
Quicklag is a registered trademark of Cutler-Hammer Inc. QO/Qwik-Guard is a registered trademark of Square D.
Panelboard
NEC & NEMA
Certifications and
Compliances
Factory
Sealed
Number
Circuits
Max.
Breaker
Frame
Size
Multi-Pole
Voltage
Max.
Trip
Rating
Amps
Max.
Circuit
Interrupting
Amps
Max.
Step
Down
Transformer
Available
D2D Cl. I, Div. 2, Groups B, C, D
NEMA: 3, 4, 7BCD, 12
Yes 42 Various 600VAC
250VDC
100 10,000 Yes
D2L Cl. I, Div. 2, Groups B, C, D
NEMA: 3, 4, 7BCD, 12
Yes 42 Quicklag
®
240VAC
125VDC
100 10,000 Yes
D2PB Cl. I, Div. 2, Groups C, D
NEMA: 3, 7CD (Div. 2), 12
Yes 24 Quicklag
®
240VAC 30 10,000 Yes
D2Z Cl. I, Zone 1, Div. 2,
Groups A, B, C, D
NEMA: 3, 4X, 7ABCD (Div. 2), 12
Corrosion Resistant,
Non-Metallic
Yes 54 CEAG 480VAC 180 10,000 No
EPL Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4, 7BCD, 9EFG, 12
Yes 42 Quicklag
®
240VAC
125VDC
100 10,000 No
EXD Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4, 7BCD, 9EFG, 12
Yes 42 Various 600VAC
250VDC
100 10,000 No
GUSC Cl. I, Div. 1 & 2, Groups C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 7CD, 9EFG, 12
No 2 Quicklag
®
240VAC 30 10,000 No
LP1 Cl. I, Div. 1 & 2, Groups B, C, D
Cl. II, Div. 1, Groups E, F, G
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4X, 7BCD, 9EFG, 12
Yes 36 Quicklag
®
240VAC 100 10,000 No
LP2 Cl. I, Div. 2, Groups B, C, D
Cl. II, Div. 2, Groups F, G
Cl. III
NEMA: 3, 4X, 7BCD, 9EFG, 12
Yes 36 Quicklag
®
240VAC 100 10,000 Yes
N2PB Cl. I, Div. 2, Groups C, D
Cl. II, Div. 2, Groups F, G
NEMA: 3, 7CD, (Div. 2), 12
Corrosion Resistant,
Non-Metallic
Yes 24 Quicklag
®
240VAC 30 10,000 No
NLP NEMA 3, 12 No 30 QO/Qwik-Guard
®
240VAC 100 10,000 No
SPB Class I, Zone 1
Cl. I, Div. 2, Groups A, B, C, D
Cl. II, Div. 1, Groups E, F, G
Yes 60 Various 480VAC 40 10,000 No
XLPB NEMA 1, 3, 3R, 4, 4X, 12 No 42 Various 600VAC 100 10,000 Yes
EATON 授权经销商 华微科技(天津)有限公司
丁先生 18622336331
剩余95页未读,继续阅读
资源评论
Eaton_华微科技
- 粉丝: 0
- 资源: 9
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
- 微软常用运行库 游戏运行库 VC++各个版本
- 微信小程序开发教程.pptx
- MyBatis动态SQL是一种强大的特性,它允许我们在SQL语句中根据条件动态地添加或删除某些部分,从而实现更加灵活和高效的数据
- 锐捷网络认证中心网络管理.pdf
- MyBatis动态SQL是一种强大的特性,它允许我们在SQL语句中根据条件动态地添加或删除某些部分,从而实现更加灵活和高效的数据
- SD8233LF是一款用于单按键触摸及接近感应开关,其用途是替代传统的机械型开关芯片IC
- 基于YOLOv5的烟雾火焰检测算法研究
- 基于STM32的联合调试侦听设备解决方案原理图PCB源文件调试工具视频(大赛作品)
- MyBatis动态SQL是一种强大的特性,它允许我们在SQL语句中根据条件动态地添加或删除某些部分,从而实现更加灵活和高效的数据
- MyBatis动态SQL是一种强大的特性,它允许我们在SQL语句中根据条件动态地添加或删除某些部分,从而实现更加灵活和高效的数据
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功