没有合适的资源?快使用搜索试试~ 我知道了~
EMC Isilon X410 boot-Drive更换手册.pdf
1.该资源内容由用户上传,如若侵权请联系客服进行举报
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
2.虚拟产品一经售出概不退款(资源遇到问题,请及时私信上传者)
版权申诉
![star](https://csdnimg.cn/release/downloadcmsfe/public/img/star.98a08eaa.png)
温馨提示
![preview](https://dl-preview.csdnimg.cn/18264235/0001-4fdaffbaef0003c35356d0688a59a8ff_thumbnail.jpeg)
![preview-icon](https://csdnimg.cn/release/downloadcmsfe/public/img/scale.ab9e0183.png)
试读
20页
EMC Isilon X410 boot-Drive更换手册
资源推荐
资源详情
资源评论
![doc](https://img-home.csdnimg.cn/images/20210720083327.png)
![zip](https://img-home.csdnimg.cn/images/20210720083736.png)
![pdf](https://img-home.csdnimg.cn/images/20210720083512.png)
![pdf](https://img-home.csdnimg.cn/images/20210720083512.png)
![docx](https://img-home.csdnimg.cn/images/20210720083331.png)
![pdf](https://img-home.csdnimg.cn/images/20210720083512.png)
![](https://csdnimg.cn/release/download_crawler_static/18264235/bg1.jpg)
Boot Drive Replacement Guide
Isilon
X400
Replace a boot drive
994-0012-01
REV H
February, 2016
l
Replacing a boot drive................................................................................................2
l
Gather logs................................................................................................................ 2
l
Install a drive support package.................................................................................. 3
l
Download a Field Replacement Unit (FRU) package.................................................... 3
l
Install the boot drive replacement..............................................................................4
l
Install the FRU package and run scripts....................................................................14
l
Update drive firmware..............................................................................................16
l
Verify a drive firmware update..................................................................................17
l
Gather logs.............................................................................................................. 18
l
Returning a failed part to Isilon................................................................................ 18
l
Update the install database..................................................................................... 18
l
Where to go for support............................................................................................19
![](https://csdnimg.cn/release/download_crawler_static/18264235/bg2.jpg)
Replacing a boot drive
You can replace a failed boot drive in the field.
This node contains two flash boot drives. The boot drives contain data vital to the health
of the node, including the OneFS operating system and backups of the node journal. The
two boot drives mirror each other, which provides a backup source of data if one of the
drives fails.
You must identify which of the two boot drives has failed before you shut down the node.
If you accidentally remove the healthy drive, the data on the node can be lost.
CAUTION
If this procedure is not followed accurately, data loss and severe disruption of cluster
operations can occur. Perform every step in this procedure; if the system does not
respond as expected, contact Isilon Technical Support.
CAUTION
Perform this procedure on only one node at a time. Performing maintenance on multiple
nodes in parallel may lower the protection level of the cluster, put data at risk, and lead
to the interruption of client workflows.
Working with clusters in SmartLock compliance mode
Clusters running in SmartLock compliance mode require a sudo prefix to run root
commands.
If a cluster is running in SmartLock compliance mode, root access is disabled on the
cluster. Because of this, you can run some commands only through the sudo program.
Prefixing a command with sudo enables you to run commands that require root access.
For example, if you do not have root access, the following command fails:
isi drivefirmware status
However, if you are on the sudoers list, the following command succeeds:
sudo isi drivefirmware status
Compliance mode commands that require changes beyond the sudo prefix are noted in
the procedure steps.
For more information on the sudo program and compliance mode commands, see the
OneFS CLI Administration Guide
.
Gather logs
Before you begin any maintenance on a cluster, gather cluster logs.
You must collect cluster logs before all maintenance procedures. Cluster logs provide
snapshots of the cluster, which you can review to make sure that maintenance is
successful.
Procedure
1. Open a secure shell (SSH) connection to any node in the cluster and log in.
Boot Drive Replacement Guide
2 X400 Boot Drive Replacement Guide
![](https://csdnimg.cn/release/download_crawler_static/18264235/bg3.jpg)
2. Gather cluster logs by running the following command:
isi_gather_info
Install a drive support package
Before you install a new drive, download and install the drive support package. The drive
support package updates drive configuration information on the node, and contains the
latest firmware versions for Isilon qualified drives.
The drive support package is only supported by clusters running OneFS 7.1.1 or later. If
your cluster is running an earlier version of OneFS, you can skip this step.
Procedure
1. Go to the EMC Support page that lists all the available versions of the drive support
package.
2. Click the latest version of the drive support package and download the file.
Note
See the Considerations for installing the latest drive support package section in order
to select the appropriate variant of the package. If you are unable to download the
package, contact EMC Isilon Technical Support for assistance.
3. Open a secure shell (SSH) connection to any node in the cluster and log in.
4. Create or check for the availability of the directory structure /ifs/data/
Isilon_Support/dsp.
5.
Copy the downloaded file to the dsp directory through SCP, FTP, SMB, NFS, or any
other supported data-access protocols.
6. Unpack the drive support package by running the following command:
tar -zxvf Drive_Support_<version>.tgz
7. Install the package by running the following command:
isi_dsp_install Drive_Support_<version>.tar
Note
You must run the isi_dsp_install command to install the dirve support package.
Do not use the isi pkg command.
Download a Field Replacement Unit (FRU) package
Before you replace a component in a configure-to-order (CTO) node, obtain a Field
Replacement Unit (FRU) package from the EMC FTP site. The FRU package updates the
CTO and as-built information on the node, then forwards the updated information to
Isilon Technical Support.
Procedure
1. Download the latest FRU package from ftp://ftp.emc.com/outgoing/Fru_Package/.
2. Note the name of the FRU package. You will use the name for other commands.
Package names follow this convention:
Replace a boot drive
Install a drive support package 3
![](https://csdnimg.cn/release/download_crawler_static/18264235/bg4.jpg)
IsiFru_Package_
<date-time-stamp>
.tgz
For example: IsiFru_Package_201507072125.tgz
3. Place the FRU package on the cluster through a network drop, or by asking someone
at the cluster site to place the package for you. If neither of these options is available
to you, contact Isilon Technical Support for assistance.
Install the boot drive replacement
Identify and remove the failed boot drive, and then install and test the replacement drive.
Write a sentinel file
Because replacement of an incorrect boot drive severely affects cluster stability, verify the
successful replacement of the failed drive. Prior to replacing the failed drive, write a
sentinel file to the root partition. After the failed drive is replaced, the file is only readable
if the correct boot drive is replaced.
Procedure
1. Use the output of isi devices as the content of the file. Write a sentinel file to the root
partition by typing the command:
isi devices > /sentinel.txt
Identify a failed boot drive
When performing a boot drive replacement on a node with two boot drives, first
determine which of the two drives must be replaced.
Procedure
1. Using a serial cable, connect to the node you are going to work on.
2. View boot drive information. Depending on your version of OneFS, run one of the
following commands:
OneFS 8.0 or later
camcontrol devlist | grep ad
The following information appears:
<SanDisk SSD P4 8GB SSD 8.10> at scbus1 target 0 lun 0
(pass13,ada0)
<SanDisk SSD P4 8GB SSD 8.10> at scbus2 target 1 lun 0
(pass14,ada1)
The boot drives are listed in the left column. In the previous example, both boot drives
are healthy. If one of the boot drives has failed, the drive will not appear in the output.
Make note of whether the failed boot drive is the ada1 or ada0 device, and then use
the following table to determine the location of the boot drive inside the node.
Boot Order
OneFS Drive ID Board Drive Slot Inside Node
Master ada1 J4
Slave ada0 J3
Boot Drive Replacement Guide
4 X400 Boot Drive Replacement Guide
剩余19页未读,继续阅读
![avatar](https://profile-avatar.csdnimg.cn/66ee842b0e90447685269c4f702f86d1_yu332116.jpg!1)
AT服务器存储
- 粉丝: 43
- 资源: 34
上传资源 快速赚钱
我的内容管理 展开
我的资源 快来上传第一个资源
我的收益
登录查看自己的收益我的积分 登录查看自己的积分
我的C币 登录后查看C币余额
我的收藏
我的下载
下载帮助
![voice](https://csdnimg.cn/release/downloadcmsfe/public/img/voice.245cc511.png)
![center-task](https://csdnimg.cn/release/downloadcmsfe/public/img/center-task.c2eda91a.png)
安全验证
文档复制为VIP权益,开通VIP直接复制
![dialog-icon](https://csdnimg.cn/release/downloadcmsfe/public/img/green-success.6a4acb44.png)
- 1
- 2
- 3
前往页