s
SIMADYN D
Technology Module T400
Configuring Instructions
T400
Edition 09.99 6DD1903-0EA0
Edition Edition
1 Technology Module T400 09.99
The reproduction, transmission or use of this document or its
contents is not permitted without express written authority.
Offenders will be liable for damages. All rights, including rights
created by patent grant or registration of a utility model or design, are
reserved.
We have checked the contents of this Manual to ensure that they
coincide with the described hardware and software. However,
deviations cannot be completely ruled-out, so we cannot guarantee
complete conformance. However, the information in this document is
regularly checked and the necessary corrections included in
subsequent editions. We are thankful for any recommendations or
suggestions.
Contents
Definitions..........................................................................................................................2
Danger and warning notes................................................................................................2
1. Configuring...................................................................................................................3
2. Installation ....................................................................................................................3
3. SIMATIC Manager .........................................................................................................5
4. HW Config .....................................................................................................................6
5. CFC..............................................................................................................................10
5.1. Calling-up blocks...........................................................................................11
5.2. Defining the sampling time ............................................................................ 13
5.3. Compilation ................................................................................................... 15
5.4. Loading ......................................................................................................... 15
5.5. Test mode .....................................................................................................19
5.6. Sheet bar/margin...........................................................................................24
6. Configuring instructions............................................................................................27
6.1. General information.......................................................................................27
6.2. Analog inputs................................................................................................. 28
6.3. Analog outputs...............................................................................................29
6.4. Digital inputs.................................................................................................. 30
6.5. Digital inputs/outputs .....................................................................................31
6.6. Absolute value encoders................................................................................33
6.7. Incremental encoders ....................................................................................36
Note ................................................................................................ 37
6.8. Communications............................................................................................39
6.8.1. General information.........................................................................39
6.8.2. Serial coupling to the configuring PC............................................... 42
6.8.3. Coupling to additional modules (e.g. CUx, ADB, CBP, CBx)............43
6.8.3.1. In the electronics box of a drive..............................................44
6.8.3.2. In the SRT400 technology subrack .........................................49
6.8.4. USS ................................................................................................53
6.8.4.1. USS master............................................................................ 53
6.8.4.2. USS slave ..............................................................................55
6.8.5. Peer to peer ....................................................................................58
6.8.6. Simolink (with SLB).........................................................................59
6.8.7. Profibus (with CB1 or CBP) .............................................................59
6.9. Parameterization ...........................................................................................59
6.9.1. Application ......................................................................................59
6.9.2. Configuring a parameter..................................................................60
6.9.3. Function blocks required..................................................................61
6.9.4. BiCo technology: Changing connections using parameters............. 63
6.9.5. Special features and restrictions for parameters and BiCo............... 63
6.10. Permanently saving values (non-volatile) .................................................... 64
7. Basic application software.........................................................................................64
Definitions
2 6DD1903-0EA0 Edition 09.99 Siemens AG
SIMADYN D Configuring Instructions T400
Definitions
NOTE
The information in these instructions does not purport to cover all details or variations in equipment, nor to provide for every possible
contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser’s purposes, please contact your local Siemens office.
Further, the contents of these instructions shall neither become a part of nor modify any prior or existing agreement, commitment or
relationship. The sales contract contains the entire obligation of Siemens. The warranty contained in the contract between the parties
is the sole warranty of Siemens. Any statements contained herein do not create new warranties nor modify the existing warranty.
Qualified personnel
For the purpose of these instructions and product labels, qualified personnel are personnel who are familiar with the installation,
mounting, start-up and operation of the equipment and the hazards involved. He or she must have the following qualifications:
1. Trained and authorized to energize, de-energize, clear, ground and tag circuits and equipment in accordance with established
safety procedures.
2. Trained in the proper care and use of protective equipment in accordance with established safety procedures.
3. Trained in rendering first aid
Danger and warning notes
!
DANGER For the purpose of these instructions and product labels, „Danger“ indicates death, severe personal
injury and/or substantial property damage will result if proper precautions are not taken.
!
WARNING For the purpose of these instructions and product labels, „Warning“ indicates death, severe
personal injury or property damage can result if proper precautions are not taken.
!
CAUTION For the purpose of these instructions and product labels, „Caution“ indicates that minor personal
injury or material damage can result if proper precautions are not taken.
NOTE For the purpose of these instructions, „Note“ indicates information about the product or the respective
part of these instructions which is essential to highlight.
!
CAUTION This board contains components which can be destroyed by electrostatic discharge. Prior to
touching any electronics board, your body must be electrically discharged. This can be simply done
by touching a conductive, grounded object immediately beforehand (e.g. bare metal cabinet
components, socket protective conductor contact.
!
WARNING Electrical equipment has components which are at dangerous voltage levels.
If these instructions are not strictly adhered to, this can result in severe bodily injury and material
damage.
It is especially important that the warning information in the relevant Operating Instructions is strictly
observed.
Configuring
Siemens AG 6DD1903-0EA0 Edition 09.99 3
SIMADYN D Configuring Instructions T400
1. Configuring
The T400 can be configured using the Windows 9x/NT-based graphic D7-ES configuring tool. This
allows even complex customer-specific supplementary functions to be easily implemented in drives.
Complete standard software packages are available for applications which are frequently used.
In the following, a T400 is configured using a small example, in order to explain the configuring
process. It is assumed that a T400 has been inserted in the righthand slot of an electronics box of a
MASTERDRIVE or DC-MASTER. A communications module is not inserted, i.e. the center slot of the
electronics box is empty.
Not all of the functions of the configuring interface will be discussed.
The diagrams were generated with version 5.0 of the configuring software.
2. Installation
The following software packages must be installed when configuring a T400: STEP7, CFC and D7-
SYS. These three packages form the D7-ES. The software must be installed in the following
sequence:
• STEP 7
• CFC
• D7-SYS
Authorization is required for STEP 7 and CFC.
The software is de-installed in the inverse sequence.
When installing STEP7, you’ll be prompted for the online interface. Initially, you do not have
to install anything for the T400:
Simply select
Close
and then, in the following window,
OK
: