s
Preface, Contents
Properties of the
PC Adapter USB
1
Package Components
2
Requirements for Operation
3
Hardware Design of the
PC Adapter USB
4
Working with the
PC Adapter USB
5
PC Adapter USB on the
MPI/DP Network
6
Firmware Update
7
Error Diagnostics
8
Technical Data
9
Appendices
Certificates, Directives and
Declarations
Certification for the USA,
Canada and Australia
A
Index
SIMATIC
PC Adapter USB
Manual
Edition 01/2004
A5E00166353-03
Copyright © Siemens AG 2003-2004 All rights reserved
The reproduction, transmission or use of this document or its
contents is not permitted without express written authority.
Offenders will be liable for damages. All rights, including rights
created by patent grant or registration of a utility model or design,
are reserved.
Siemens AG
Bereich Automation and Drives
Geschaeftsgebiet Industrial Automation Systems
Postfach 4848, D- 90327 Nuernberg
Disclaimer of Liability
We have checked the contents of this manual for agreement with
the hardware and software described. Since deviations cannot be
precluded entirely, we cannot guarantee
full agreement. However,
the data in this manual are reviewed regularly and any necessary
corrections included in subsequent editions. Suggestions for
improvement are welcomed.
©Siemens AG 2003-2004
Technical data subject to change.
Siemens Aktiengesellschaft A5E00166353-03
Safety Guidelines
This manual contains notices intended to ensure personal safety, as well as to protect the products and
connected equipment against damage. These notices are highlighted by the symbols shown below and
graded according to severity by the following texts:
!
Danger
indicates that death, severe personal injury or substantial property damage will result if proper
precautions are not taken.
!
Warning
indicates that death, severe personal injury or substantial property damage can result if proper
precautions are not taken.
!
Caution
indicates that minor personal injury can result if proper precautions are not taken.
Caution
indicates that property damage can result if proper precautions are not taken.
Notice
draws your attention to particularly important information on the product, handling the product, or to a
particular part of the documentation.
Qualified Personnel
Only qualified personnel should be allowed to install and work on this equipment. Qualified persons
are defined as persons who are authorized to commission, to ground and to tag circuits, equipment, and
systems in accordance with established safety practices and standards.
Correct Usage
Note the following:
!
Warning
This device and its components may only be used for the applications described in the catalog or the
technical description, and only in connection with devices or components from other manufacturers
which have been approved or recommended by Siemens.
This product can only function correctly and safely if it is transported, stored, set up, and installed
correctly, and operated and maintained as recommended.
Trademarks
SIMATIC®, SIMATIC HMI® and SIMATIC NET® are registered trademarks of SIEMENS AG.
Third parties using for their own purposes any other names in this document which refer to trademarks
might infringe upon the rights of the trademark owners.
PC Adapter USB
A5E00166353-03
iii
Preface
Purpose of the Manual
This manual gives you a complete overview of PC Adapter USB. It guides you
when installing and commissioning the software and hardware. It also describes
the operation and hardware installation requirements, as well as, the connection of
the Adapter to MPI/DP networks.
This manual is intended for the programmers and for those responsible for
configuring, commissioning, and servicing automation systems.
Required Basic Knowledge
You require a general knowledge in the field of automation engineering to be able
to understand this manua.
In addition, you should know how to use computers or devices with similar
functions (e.g programming devices) under Windows 2000 or Windows XP
operating systems.
Where is this Manual valid?
This manual is valid for the product PC Adapter USB.
Preface
PC Adapter USB
iv A5E00166353-03
Certification
PC Adapter USB have the following certification:
• Underwriters Laboratories, Inc.: UL 60950 registered and Canadian Standard
C22.2 No. 60950 (Information Technology Equipment)
CE Labeling
PC Adapter USB fulfil the requirements and protection guidelines of the following
EU directives:
• EC Directive 89/336/EWG "EMC directive"
CTick Mark
PC Adapter USB is compliant with requirements of the AS/NZS 3548 (Australian
and New Zeeland) standard.
Further Support
If you have any technical questions, please get in touch with your Siemens
representative or agent responsible.
You will find your contact person at:
http://www.siemens.com/automation/partner
Training Centers
Siemens offers a number of training courses to familiarize you with the SIMATIC
S7 automation system. Please contact your regional training center or our central
training center in D 90327 Nuremberg, Germany for details:
Telephone: +49 (911) 895-3200.
Internet: http://www.sitrain.com
Preface
PC Adapter USB
A5E00166353-03
v
A&D Technical Support
Worldwide, available 24 hours a day:
Beijing
Peking
Nuernberg
Johnson City
Worldwide (Nuernberg)
Technical Support
24 hours a day, 365 days a year
Phone: +49 (180) 5050-222
Fax: +49 (180) 5050-223
E-Mail: adsupport@
siemens.com
GMT: +1:00
Europe / Africa (Nuernberg)
Authorization
Local time: Mon.-Fri. 8:00 to 5:00 PM
Phone: +49 (180) 5050-222
Fax: +49 (180) 5050-223
E-Mail: adsupport@
siemens.com
GMT: +1:00
United States (Johnson City)
Technical Support and
Authorization
Local time: Mon.-Fri. 8:00 to 5:00 PM
Phone: +1 (423) 262 2522
Fax: +1 (423) 262 2289
E-Mail: simatic.hotline@
sea.siemens.com
GMT: -5:00
Asia / Australia (Beijing)
Technical Support and
Authorization
Local time: Mon.-Fri. 8:00 to 5:00 PM
Phone: +86 10 64 75 75 75
Fax: +86 10 64 74 74 74
E-Mail: adsupport.asia@
siemens.com
GMT: +8:00
The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English.