5
TL431-Q1
,
TL432-Q1
www.ti.com.cn
ZHCSK06F –MARCH 2005–REVISED JULY 2019
Copyright © 2005–2019, Texas Instruments Incorporated
Electrical Characteristics: TL43x-Q1 (continued)
over recommended operating conditions, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
REF
Reference current I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞, see Figure 21 2 4 µA
I
I(DEV)
Deviation of reference current over full
temperature
(1)
I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞,
T
A
= –40°C to 125°C, see Figure 21
0.8 2.5 µA
I
MIN
Minimum cathode current for regulation V
KA
= V
REF
, see Figure 20 0.4 1 mA
I
OFF
OFF-state cathode current V
KA
= 36 V, V
REF
= 0, see Figure 22 0.1 1 µA
|Z
KA
| Dynamic impedance
(1)
I
KA
= 1 mA to 100 mA, V
KA
= V
REF
, f ≤ 1 kHz,
see Figure 20
0.2 0.5 Ω
(1) The deviation parameters (V
I(DEV)
and I
I(DEV)
) are defined as the differences between the maximum and minimum values obtained over
the recommended temperature range.
6.6 Electrical Characteristics: TL43xA-Q1
over recommended operating conditions, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
REF
Reference voltage V
KA
= V
REF
, I
KA
= 10 mA, see Figure 20 2470 2495 2520 mV
V
I(DEV)
Deviation of reference voltage over full
temperature
(1)
V
KA
= V
REF
, I
KA
= 10 mA, T
A
= –40°C to 125°C,
see Figure 20
14 34 mV
ΔV
REF
/ΔV
KA
Ratio of change in reference voltage to the
change in cathode voltage
I
KA
= 10 mA,
see Figure 21
ΔV
KA
= 10 V – V
REF
–1.4 –2.7
mV/V
ΔV
KA
= 36 V – 10 V –1 –2
I
REF
Reference current I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞, see Figure 21 2 4 µA
I
I(DEV)
Deviation of reference current over full
temperature
(1)
I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞,
T
A
= –40°C to 125°C, see Figure 21
0.8 2.5 µA
I
MIN
Minimum cathode current for regulation V
KA
= V
REF
, see Figure 20 0.4 0.7 mA
I
OFF
OFF-state cathode current V
KA
= 36 V, V
REF
= 0, see Figure 22 0.1 0.5 µA
|Z
KA
| Dynamic impedance
(1)
I
KA
= 1 mA to 100 mA, V
KA
= V
REF
, f ≤ 1 kHz,
see Figure 20
0.2 0.5 Ω
(1) The deviation parameters (V
I(DEV)
and I
I(DEV)
) are defined as the differences between the maximum and minimum values obtained over
the recommended temperature range.
6.7 Electrical Characteristics: TL43xB-Q1
over recommended operating conditions, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
REF
Reference voltage V
KA
= V
REF
, I
KA
= 10 mA, see Figure 20 2483 2495 2507 mV
V
I(DEV)
Deviation of reference voltage over full
temperature
(1)
V
KA
= V
REF
, I
KA
= 10 mA, T
A
= –40°C to 125°C,
see Figure 20
14 34 mV
ΔV
REF
/ΔV
KA
Ratio of change in reference voltage to the
change in cathode voltage
I
KA
= 10 mA,
see Figure 21
ΔV
KA
= 10 V – V
REF
–1.4 –2.7
mV/V
ΔV
KA
= 36 V – 10 V –1 –2
I
REF
Reference current I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞, see Figure 21 2 4 µA
I
I(DEV)
Deviation of reference current over full
temperature
(1)
I
KA
= 10 mA, R1 = 10 kΩ, R2 = ∞,
T
A
= –40°C to 125°C, see Figure 21
0.8 2.5 µA
I
MIN
Minimum cathode current for regulation V
KA
= V
REF
, see Figure 20 0.4 0.7 mA
I
OFF
OFF-state cathode current V
KA
= 36 V, V
REF
= 0, see Figure 22 0.1 0.5 µA
|Z
KA
| Dynamic impedance
(1)
I
KA
= 1 mA to 100 mA, V
KA
= V
REF
, f ≤ 1 kHz,
see Figure 20
0.2 0.5 Ω
评论0