GETTING STARTED GUIDE
NI USB-5132/5133
Bus-Powered USB Oscilloscope
This document explains how to install, configure, and test the NI USB-5132/5133
(NI 5132/5133). The NI 5132/5133 is a bus-powered USB oscilloscope.
To access NI 5132/5133 documentation, navigate to Start»All Programs»
National Instruments»NI-SCOPE»Documentation. In Windows 8, click NI Launcher and
select NI-SCOPE in the window that appears.
Contents
Electromagnetic Compatibility Guidelines...............................................................................2
Verifying the System Requirements..........................................................................................2
Unpacking the Kit..................................................................................................................... 2
Preparing the Environment....................................................................................................... 3
USB Modules....................................................................................................................3
Kit Contents.............................................................................................................................. 3
Other Equipment............................................................................................................... 4
Installing the Software.............................................................................................................. 4
Installing the Hardware.............................................................................................................4
Providing USB Cable Strain Relief.................................................................................. 5
Mounting the USB Device................................................................................................6
Configuring the NI 5132/5133 in MAX................................................................................... 8
Programming the NI 5132/5133............................................................................................... 9
NI-SCOPE Examples......................................................................................................10
Programming Flow..........................................................................................................11
Making a Measurement...........................................................................................................12
Making a Measurement with NI-SCOPE SFP................................................................12
Making a Measurement with LabVIEW.........................................................................12
Troubleshooting...................................................................................................................... 12
What Should I Do if the NI 5132/5133 Doesn't Appear in MAX?.................................12
What Should I Do if the Device Fails the Self-Test?...................................................... 13
What Should I Do if the Back Panel LED Remains Off When the NI 5132/5133 is
Plugged In?............................................................................................................... 13
Where to Go Next................................................................................................................... 13
Worldwide Support and Services............................................................................................ 14
Electromagnetic Compatibility Guidelines
This product was tested and complies with the regulatory requirements and limits for
electromagnetic compatibility (EMC) stated in the product specifications. These requirements
and limits provide reasonable protection against harmful interference when the product is
operated in the intended operational electromagnetic environment.
This product is intended for use in industrial locations. However, harmful interference may
occur in some installations, when the product is connected to a peripheral device or test object,
or if the product is used in residential or commercial areas. To minimize interference with
radio and television reception and prevent unacceptable performance degradation, install and
use this product in strict accordance with the instructions in the product documentation.
Furthermore, any changes or modifications to the product not expressly approved by National
Instruments could void your authority to operate it under your local regulatory rules.
Caution To ensure the specified EMC performance, operate this product only with
shielded cables and accessories.
Caution This product may become more sensitive to electromagnetic disturbances
in the operational environment when test leads are attached or when connected to a
test object.
Caution To ensure the specified EMC performance, the length of all I/O cables
must be no longer than 3 m (10 ft).
Verifying the System Requirements
To use the NI-SCOPE instrument driver, your system must meet certain requirements.
Refer to the product readme, which is available on the driver software media or online at
ni.com/manuals, for more information about minimum system requirements,
recommended system, and supported application development environments (ADEs).
Unpacking the Kit
Caution To prevent electrostatic discharge (ESD) from damaging the device,
ground yourself using a grounding strap or by holding a grounded object, such as
your computer chassis.
1. Touch the antistatic package to a metal part of the computer chassis.
2. Remove the device from the package and inspect the device for loose components or any
other sign of damage.
Caution Never touch the exposed pins of connectors.
2 | ni.com | NI USB-5132/5133 Getting Started Guide
电磁兼容性指南
为保证指定的EMC性能,请仅使用屏蔽电缆和附件操作本产品。
当连接测试导线或连接到测试对象时,本产品可能对操作环境中的电磁
干扰更加敏感。
为了保证EMC性能,所有I/O线缆的长度不能超过3m(10英尺)。
验证系统需求
要使用NI-SCOPE仪器驱动程序
拆包
为防止静电损坏设备,请使用接地带或手拿已接地的物体(如计算机机箱)接地。
用手触摸电脑机箱的金属部件。
从包装中取出设备,检查设备是否有松动的部件或任何其他损坏迹象。
请勿触摸连接器外露的引脚
Note Do not install a device if it appears damaged in any way.
3. Unpack any other items and documentation from the kit.
Store the device in the antistatic package when the device is not in use.
Preparing the Environment
Ensure that the environment in which you are using the NI 5132/5133 meets the following
specifications:
USB Modules
Operating Environment
....................................................................Ambient temperature range 0 °C to 45 °C (Tested in accordance with
IEC 60068-2-1 and IEC 60068-2-2.)
....................................................................Relative humidity range 10% to 90%, noncondensing (Tested in
accordance with IEC 60068-2-56.)
............................................................................Maximum altitude 2,000 m (at 25 °C ambient temperature)
............................................................................Pollution Degree 2
Indoor use only.
Kit Contents
Figure 1. NI 5132/5133 Kit Contents
4
5
3
2
1
1. NI USB-5132/5133 Device
2. USB cable
3. Rubber feet for secure desktop use
4. Driver Software DVD
5. NI USB-5132/5133 Getting Started Guide (this
document)
NI USB-5132/5133 Getting Started Guide | © National Instruments | 3
从工具包中拆包任何其他项目和文档。
不使用设备时,请将设备保存在防静电包装袋中。
环境的准备
请确保NI 5132/5133的使用环境符合以下规范
操作环境
环境温度范围0°C ~ 45°C(按照IEC 60068-2-1和IEC 60068-2-2测试。)
湿度范围10% - 90%,无凝露(按照IEC 60068-2-56测试)
最高海拔2000米(环境温度25°C)
污染程度2
仅限室内使用
Other Equipment
There are required items not included in your device kit that you need to install or operate the
NI 5132/5133.
• 1/8 in. flat-head screwdriver (for mounting your device to a standard DIN rail)
• A desktop or laptop computer and its documentation
Installing the Software
You must be an Administrator to install NI software on your computer.
1. Install an ADE, such as LabVIEW or LabWindows
™
/CVI
™
.
2. Insert the driver software media into your computer. The installer should open
automatically.
If the installation window does not appear, navigate to the drive, double-click it, and
double-click autorun.exe.
3. Follow the instructions in the installation prompts.
Note Windows users may see access and security messages during
installation. Accept the prompts to complete the installation.
Note If installing from the NI Device Drivers DVD, select Modular
Instruments»NI-SCOPE for installation.
4. When the installer completes, select Restart in the dialog box that prompts you to restart,
shut down, or restart later.
5. If you are using a system running the LabVIEW Real-Time Module, download
NI-SCOPE to the target using Measurement & Automation Explorer (MAX). For more
information, refer to the Max Remote Systems Help by selecting Help»Help Topics»
Remote Systems in MAX.
Installing the Hardware
To install the NI 5132/5133, connect the USB cable to the PC and the oscilloscope.
4 | ni.com | NI USB-5132/5133 Getting Started Guide
其他设备
需要安装或操作NI 5132/5133的设备套件中不包含所需的项目。
台式机或笔记本电脑及其文档
在1/8。一字螺丝刀(用于将设备安装到标准DIN导轨上)
安装软件
你必须是管理员才能在你的计
算机上安装NI软件。
安装一个ADE,如LabVIEW或LabWindows™/CVI™。
将驱动程序软件介质插入计算机。安装程序应该自动打开。
如果没有出现安装窗口,请进入驱动器,双击该驱动器,然后
双击“autorun.exe”。
请按照安装提示中的说明进行操作
Windows用户可能在安装期间看到访问和安全消息。接受提示完成安装。
如果是从NI Device Drivers DVD安装,选择Modular Instruments»NI- scope进行安装。
安装程序完成后,在提示重新启动、关闭或稍后重新启动的对话框中选择“重新启动”。
如果您正在使用运行LabVIEW实时模块的系统,请使用测量和自动化资源管理器(MAX)下载NI-SCOPE到
目标。有关更多信息,请参阅Max中的“最大远程系统帮助”,选择“帮助»帮助主题»远程系统”。
安装的硬件
安装NI 5132/5133时,将USB线连接到PC和示波器上。
剩余15页未读,继续阅读
音尘star
- 粉丝: 20
- 资源: 2
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
- 111111111111111111111
- 汉诺塔python代码递归
- 汉诺塔python代码递归
- 汉诺塔python代码递归
- MySQL 8.0 实战教程从入门到项目实战.docx
- 汉诺塔问题是一个经典的递归问题 在这个问题中,我们有三个塔座(通常被称为A、B和C),并且我们有一堆大小不同的盘子,每个盘子都可
- TB-03 二次开发环境搭建指导
- 汉诺塔问题是一个经典的递归问题 在这个问题中,我们有三个塔座(通常被称为A、B和C),并且我们有一堆大小不同的盘子,每个盘子都可
- 汉诺塔问题是一个经典的递归问题 在这个问题中,我们有三个塔座(通常被称为A、B和C),并且我们有一堆大小不同的盘子,每个盘子都可
- 遗传粒子群算法(GA),MATLAB源代码,解决旅行商问题(TSP)
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功
评论0