4.1 确认命令
68 45 00 68 4A 11 00 00 88 FF FF FF 00 00 00 01 02 03 04 05 06 F5 16
4.2 复位命令
68 49 00 68 4A 11 00 00 88 FF FF FF 01 02 00 00 01 02 03 04 05 06 F8 16
4.4.1 设置遥测站的时钟(AFN=03H)
68 3D 00 68 4A 11 00 00 88 FF FF FF 03 06 A8 18 08 59 00 0A 16
68 3D 00 68 4A 11 00 00 88 FF FF FF 03 00 59 08 18 A8 06 0A 16
读遥测站的时钟(AFN=03H)
68 25 00 68 4A 11 00 00 88 FF FF FF 04 E4 16
4.4.2 设置遥测站的地址(AFN=05H)
68 61 00 68 4A 11 00 00 88 FF FF FF 05 11 00 00 00 01 02 03 00 00 01 02 03 04 05 06 11 16
4.4.3 查询遥测站的地址(AFN=06H)
68 25 00 68 4A 11 00 00 88 FF FF FF 06 E6 16
4.4.4 设置遥测站的工作模式(AFN=07H)
68 49 00 68 4A 11 00 00 88 FF FF FF 07 02 00 00 01 02 03 04 05 06 FE 16
4.4.5 查询遥测站的工作模式(AFN=08H)
68 25 00 68 4A 11 00 00 88 FF FF FF 08 E8 16
4.4.6 设置遥测站的数据上报时间间隔(AFN=09H)
68 4D 00 68 4A 11 00 00 88 FF FF FF 09 10 00 00 00 01 02 03 04 05 06 0E 16
4.4.7 查询遥测站的数据上报时间间隔(AFN=0AH)
68 25 00 68 4A 11 00 00 88 FF FF FF 0A EA 16
4.4.8 设置遥测站的表底值(AFN=0BH)
68 55 00 68 4A 11 00 00 88 FF FF FF 0B 78 56 34 12 00 00 01 02 03 04 05 06 14 16
4.4.9 查询遥测站的流量仪表的实时值(AFN=0CH)
68 25 00 68 4A 11 00 00 88 FF FF FF 0C EC 16
4.4.10 设置遥测站的阶梯水价(AFN=0DH)
4.4.12 设置遥测站的本次充值量(AFN=0FH)
68 55 00 68 4A 11 00 00 88 FF FF FF 0F 00 00 10 00 00 00 01 02 03 04 05 06 14 16
4.4.13 查询遥测站最近一次成功充值量(AFN=10H)
68 25 00 68 4A 11 00 00 88 FF FF FF 10 F0 16
4.4.14 查询遥测站累计成功充值量和充值次数(AFN=11H)
68 25 00 68 4A 11 00 00 88 FF FF FF 11 F1 16
4.4.15 设置遥测站的剩余水量报警值(AFN=12H)
68 51 00 68 4A 11 00 00 88 FF FF FF 12 00 01 00 00 00 01 02 03 04 05 06 08 16
4.4.16 查询剩余水量和报警值(AFN=13H)
68 25 00 68 4A 11 00 00 88 FF FF FF 13 F3 16
4.4.18 设置遥测站的井口高度、水位下限及水位计量程(AFN=14H)
68 65 00 68 4A 11 00 00 88 FF FF FF 14 01 02 03 00 10 00 00 10 00 00 01 02 03 04 05 06 2F 16
4.4.19 查询遥测站的井口高度、水位下限及水位计量程(AFN=15H)
68 25 00 68 4A 11 00 00 88 FF FF FF 15 F5 16
4.4.20 查询实时水位(AFN=16H)
68 25 00 68 4A 11 00 00 88 FF FF FF 16 F6 16
4.4.21 设置遥测站的SIM卡号(AFN=17H)
68 5D 00 68 4A 11 00 00 88 FF FF FF 17 01 02 03 04 05 06 00 00 01 02 03 04 05 06 21 16
4.4.22 查询遥测站的SIM卡号(AFN=18H)
68 25 00 68 4A 11 00 00 88 FF FF FF 18 F8 16
4.4.23 查询历史记录(AFN=19H)
68 29 00 68 4A 11 00 00 88 FF FF FF 19 10 09 16
4.4.24 读取遥测站时实值(AFN=1AH)
68 25 00 68 4A 11 00 00 88 FF FF FF 1A FA 16
4.4.25 清空历史数据(AFN=1BH)
68 25 00 68 4A 11 00 00 88 FF FF FF 1B FB 16
4.4.26 设置遥测站的事件及开关量参数(AFN=1CH)
68 95 00 68 4A 11 00 00 88 FF FF FF 1C 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 01 02 03 04 05 06 11 16
68 95 00 68 4A 11 00 00 88 FF FF FF 1C 00 00 06 70 00 00 06 70 00 00 00 FF 00 00 00 00 00 00 00 00 00 00 01 02 03 04 05 06 FC 16
4.4.27 读取遥测站的事件及开关量参数(AFN=1DH)
68 25 00 68 4A 11 00 00 88 FF FF FF 1D FD 16
4.4.28 中心站对遥测站主动上报数据的确认(AFN=1EH)
68 29 00 68 4A 11 00 00 88 FF FF FF 1E 01 FF 16
4.4.29 读取遥测事件代码、开关量及报警状态(AFN=1FH)
68 25 00 68 4A 11 00 00 88 FF FF FF 1F FF 16
4.4.30 设置电机额定工作参数(AFN=20H)
68 55 00 68 4A 11 00 00 88 FF FF FF 20 01 02 03 04 00 00 01 02 03 04 05 06 1F 16
4.4.31 读取电机额定工作参数(AFN=21H)
68 25 00 68 4A 11 00 00 88 FF FF FF 21 01 16
4.4.32 读取电机实时工作参数(AFN=22H)
68 25 00 68 4A 11 00 00 88 FF FF FF 22 02 16
4.4.32 打开水泵或阀门(AFN=30H)
68 45 00 68 4A 11 00 00 88 FF FF FF 30 00 00 01 02 03 04 05 06 25 16
4.4.33 关闭水泵或阀门(AFN=31H)
68 45 00 68 4A 11 00 00 88 FF FF FF 31 00 00 01 02 03 04 05 06 26 16
4.4.34 设置IC卡功能有效(AFN=32H)
68 45 00 68 4A 11 00 00 88 FF FF FF 32 00 00 01 02 03 04 05 06 27 16
4.4.35 取消IC卡功能有效(AFN=33H)
68 45 00 68 4A 11 00 00 88 FF FF FF 33 00 00 01 02 03 04 05 06 28 16
两控制器间通讯协议
显示主要参数
AA 01 剩余水表 累计水量 瞬时流量 蓄电 锂电 液位 水泵 CS EE
AA 10 01 00 00 01 02 00 00 01 03 01 04 24 01 1234 01 32 EE
备用RS485仪表通讯协议:(RTU-MODBUS协议)
设置IO口状态
68 05 01 00 00 00 00 01 18//V220供电
68 05 01 00 00 00 01 02 18//蓄电供电
读IO口状态
68 03 02 00 00 02 18//读IO口状态
68 05 02 00 00 00 01 03 18//状态返回
8 21H
9 25H
10 29H
11 2DH
12 31H
13 35H
14 39H
15 3DH
16 41H