TEMPERATURE
- INSTRUMENT AIR SUPPLY
UNIT NO.
QRS
*E
FI
SR
TDR
FAL
TY
FIT
UT
VSL
CR
R/S
PDC
TDCV
FLOW SWITCH, SPST
OPENS ON DECREASING
FLOW
DI
KT
-C
C-
LSL
PZ
XC
ZIC
3. NUMBERING SHALL FOLLOW THE SAME PROCEDURE AS INSTRUMENTS.
O/C
SIS
QRC
LETTER CODE PER TABLE
RELAY COIL
DCS INTERLOCK
NO.001
TDRC
SIT
LG
Z
TX
FA
UV
FRS
VS
CIT
SEL
JX
KR
-
KV
-
THE SUFFIX LETTER "E" IS TO BE USED TO IDENTIFY COMPONENTS OF
A SAFETY SYSTEM - I.E.- SHUTDOWN, DEPRESSURING, LOCK UP, ETC.,
(PALE - ALARM ON LOW PRESSURE SHUTDOWN).
LS
-
FUNCTION IN DCS SYSTEM
DISPLAY TO OPERATE
XAL
TDRS
PDA
ZI
FOR ELABORATE CONTROL SYSTEMS A SEPARATE DRAWING (EITHER VENDOR OR CONTRACTOR) MAY BE REQUIRED.
IN SUCH A CASE, A BLOCK WILL BE DRAWN ON THE P&ID WITH A DRAWING NUMBER IDENTIFICATION AND SHOWING
ALL THE INPUT AND OUTPUT SIGNALS.
RECORDING SWITCH
FO
FC-245 017
B = BLUE
QRT
SIS INTERLOCK
NO.002
TW
SRS
X
1. ALL REDUNDANT TRANSMITTERS HAVE DEVIATION ALARMS IN THE DCS.
THE DEVIATION ALARMS ARE NOT SHOWN ON THE P&ID.
TR
FRC
UY
IRS
VT
TDRT
CIS
R/S
JR
KR
DE
-
KY
BA
LT
MSL
XA
PDZ
-
FIELD OR LOCAL
INSTRUMENT
RECORDING CONTROLLER
FE
QIS
G = GREEN
TDSL
RELAY
FUNCTION
=SUMMING
SRC
TG
ALARM
W
TIT
FUNCTIONAL LOGIC DIAGRAMS
HIS
UX
IRC
VV
CIK
JIT
KX
LV
FFAL
MS
TDT
XZ
PCV
ZE
LOOP NO.
INDICATING TRANSMITTER
A/S
Y = AMBER
QIK
RELAY TRANSDUCER ETC
DRIVE OR ACTUATOR
PG
SRT
-
V
INSTRUMENT FUNCTION
TRS
HIK
UR
FFRC
IRT
TDV
VY
JRS
APPLICATION OF INSTRUMENT IDENTIFICATION TO P.&I.D.'S
KR
LY
MT
SWITCH
SWITCH LOW (L), MEDIUM (M), HI (H)
PSL
ZC
INSTRUMENT
FUNCTION
FFRS
QIC
R = RED
SIS
FRT
GE
U
TRC
HIC
UIT
R
IIS
INDICATING SWITCH
VX
EC
WS
KIT
RECORDER
LX
FFRT
MV
PS
ZAL
LP -
INDICATING CONTROLLER
INDICATING CONTROL STATION
INSTRUMENT ABBREVIATION
SPEED
QI
LEGEND FOR
GC
T
TRT
HI
FFSL
URS
IIK
VR
JRT
WT
EAL
KRS
IS USED FOR SCANNING - I.E.- FOR TEMPERATURE TJI OR TJR.
ART
LR
MY
PT
ZA
-
FQIC
START HAND MANUAL
STOP OFF TRIP
RUN AUTO RESET
READY JOG ARMED
FUNCTIONAL ABBREVIATIONS MAYBE USED:
-S/S - START/STOP
-HOA - HAND-OFF-AUTO
-
QUANTITY
OR EVENT
SIC
GAL
TIS
-
URC
IIC
VIT
EA
JIS
WV
J-
KRCARC
FQIK
LIT
MX
E -
PV
ZZ
-
GENERAL_INSTRUMENTS_SYSTEMS
PILOT LIGHT
2. SOME TYPICAL FUNCTIONS ARE:
PRESSURE
DIFFERENCE
QE
SI
GA
TIK
FQRC
-
URT
II
HARDWIRED SHUTDOWN INTERLOCK SYSTEM
VRS
JIK
WY
INSTRUMENT IDENTIFICATION LETTERS
KRT
AR
LRS
-
MR
B
PY
FFC
NOTES
FQRS
QC
S
PRESSURE
-
GZ
TIC
HC
UIS
-
VRC
MEASURED VARIABLES
JIC
WX
FIS
R-
KIS
FQRT
AIT
CI
LRC
A
X -
MIT
AZ
Y -
PX
GE F
NOTES
MOISTURE OR
HUMIDITY
QAL
SE
FFA
FQSL
TI
HAL
UIK
-
EXAMPLE
VRT
JI
WR
OPEN CLOSED HAND SWITCH MOUNTED ON A LOCAL PANEL FOR ACTUATING
A "XV" ON/OFF VALVE.
DCS COMPOSITE POINT SELECTOR SWITCH WITH OPEN/CLOSED INDICATION
FROM "XV" LIMIT SWITCHES OR POSITION TRANSMITTER.
FIK KIK
MISCELLANEOUS
- REMOTE SET POINT
GRC
GAUGE GLASS (TUBE)
TRANSMITTER
QS
PUSHBUTTON, MOMENTARY TYPE
NORMALLY OPEN CONTACT BLOCK
HR
ZY
-
- DIAL THERMOMETER
EI
IY
UA
ERC
"NAND" LOGIC GATE
FQR
JT
TDC
PDSL
L-
VC
FSL KSL
-
CX
DR
BX
SOLENOID VALVE
ON EMERGENCY
SYSTEMS
MOTOR CONTROL DISPLAYS IN THE DCS ARE DESIGNATED AS BELOW:
ANALYZER
FLOW RATIO
WEIGHT
WCV
ELEMENT
V
GRT
PUSHBUTTON, MOMENTARY TYPE
NORMALLY CLOSED CONTACT BLOCK
QT
ZX
-
- PRESSURE GAUGES
SSL
2.
IX
ERT
UZ
"NOR" LOGIC GATE
LP
FQIT
JV
FS
VAL
PC
CV
DIT
WRC
BS
BACK OF PANEL
OR RACK MOUNTED
INSTRUMENT
TDA
MOTOR CONTROL
XIS
FLOW
RTD
GIS
CONTROL VALVE (SELF OPERATING)
QV
LEVEL SWITCH, SPST
OPENS ON DECREASING
LEVEL
HRS
ZR
SS
RV
-
IR
TCV
FI
"AND" LOGIC GATE
WRS
O/C
MZ
VA
FT
WC
CT
DRS
BV
WILL BE USED OUTSIDE BALLOON TO IDENTIFY VENDOR SUPPLIED INSTRUMENTS.
TDZ
PDRC
HEXAGON DENOTES COMPUTER OR RTU FUNCTION
XIK
VOLTAGE (EMF)
WRT
3.
CONTROL
SP
GIK
PRESSURE SWITCH, SPST
OPENS ON DECREASING
PRESSURE
QY
ZIT
HRC
FSV
ST
-
FG
KS
TSL
TDAL
"OR" LOGIC GATE
FV
FQIS
VZ
WAL
CSL
TO PUMP
P-100B MOTOR
DRC
WSL
-
TWO STAGE VABIABLE ALARMS SHALL BE IDENTIFIED BY H AND HH,
OR L AND LL, - I.E.- H- HIGH LEVEL ALARM
- HH- VERY HIGH LEVEL ALARM
NOTE: SAFETY SYSTEM WILL BE GENERALLY BE HE NOT HHE.
SIS INTERLOCK
XIC
DENSITY
VISCOSITY
-
- SAFETY INSTRUMENTED SYSTEM
GIC
ALARM LOW (L), MEDIUM (M), HI (H)
QX
LIMIT SWITCH
SINGLE - POLE
SINGLE - THROW [SPST]
JIY
SV
RV
-
LOOP NO.
XRC
TS
FE
S
1.
UCV
FY
WA
CS
TO PUMP
P-100A MOTOR
DRT
TDIC
BG
H/L -
DCS OR PLC INTERLOCK
XI
ZRT
6.
XRS
MULTI VARIABLE
- FLOW RESTRICTION ORIFICE
FQZ
ELECTRONIC ALARM RELAY CONTACT
OPEN ON POWER FAILURE AND ABOVE
HI OR BELOW LO SET POINTS. CLOSED
DURING NORMAL OPERATING LIMITS.
IIT
QR
PDI
PSE
SY
H
FCV
TT
TDIK
F
FX
USL
WZ
CRT
HOA
XRT
DIC
BE
V -
FQAL
PAL
DUAL FUNCTION (FOR SERVICES) INSTRUMENT
XG
ZIS
5. INDICATING LIGHTS SHALL BE COLOR CODED AS FOLLOWS:
RUNNING/OPEN - BLUE
STOPPED/CLOSED - YELLOW
TDIS
TEMPERATURE
DIFFERENCE
-
- FLOW ELEMENT
QIT
CONTACTS
HEAT TRACED
TRANSMITTER
SX
FG
ZRC
TV
FC
US
AS A GENERAL GUIDE, THE EXTENT OF INSTUMENTATION SHOWN ON THE P&ID SHOULD BE SUFFICIENT TO PERMIT
THE OBSERVER TO IDENTIFY THE MAIN COMPONENTS AND THE FINAL READOUT CONTROL AND/OR ALARM ACTION
AND TO UNDERSTAND THE FULL FUNCTION OF THE INSTRUMENT SYSTEM. IDENTIFICATION OF ALL COMPONENTS
AND THE FULL SCHEMATIC RELATIONSHIP ARE SHOWN ON THE INSTRUMENT HARD WIRED LOOP DWGS.
START/STOP AND H-O-A HAND SWITCHES FOR PUMP "A" WILL HAVE A
SEQUENTIAL NUMBER. A DIFFERENT SEQUENTIAL NUMBER IS USED FOR PUMP "B".
THE DCS SOFT DEVICE BLOCK TAG WILL NOT HAVE A SUFFIX (I.E. HS-110) THE
LOCAL HAND SWITCHES FOR H-O-A AND LOCAL START/STOP WILL HAVE SUFFIX
STARTING WITH A (I.E. HS-110A). COMMON HAND SWITCH FOR BOTH PUMPS
(I.E. SELECTOR SWITCH) WILL HAVE ITS OWN SEQUENTIAL NUMBER.
ALL CONTROLLERS COMING INTO DCS DO NOT NEED TO BE MARKED AS AN IC OR
RC AS I AND R ARE IMPLICIT FOR EVERY POINT.
ALARM PRESENTATION (MINIMIZE NUMBER OF BALLOONS)
THE OPERATOR HAS THE ABILITY TO SET AN H OR L FOR ANY POINT.
THESE OPERATOR ALERTS WILL NOT BE SHOWN ON P&ID ALARMS UNDER ENGINEERING CHANGE
CONTROL WILL BE SHOWN AS:
FAILURE ACTION FOR SOLENOID AND PNEUMATIC 3-WAY INSTRUMENT VALVES
WILL BE SHOWN WITH AND ARROW AND FO, FC, NOMENCLATURE- SIMILAR TO THAT
USED FOR CONTROL VALVES.
IS USED TO SHOW A MULTIFUNCTION INSTRUMENT. - I.E.- COMBINATION
RECORDING SCANNING, TOTALIZING, ETC. OR MULTIFUNCTION SYSTEM
THAT MAY BE DETAILED SEPARATELY.
AIS
CIC
LRT
XCV
1
HZ
MRSARS
IS USED TO IDENTIFY COMPUTING TYPE RELAYS, FUNCTION CAN BE
SHOWN OUTSIDE BALLOON.
PR
FQ
FQI
PDAL
MOTOR CONTROL ITEMS ON LOCAL PANEL OR FIELD MOUNTED ARE DESIGNATED AS BELOW:
L - INDICATING LIGHT, IF ASSOCIATED WITH HAND SWITCHES
OR PUSH BUTTONS OR ALARM IF USED FOR ALARM AL, ALH
QA
LEVEL
SC
TG
HA
WITH THE EXCEPTION OF HAND SWITCHES, FOR INSTRUMENTS THAT ARE LOCATED ON IDENTICAL PARALLEL EQUIPMENT,
THE IDENTICAL INSTRUMENTS ON EACH PIECE OF EQUIPMENT SHALL BE NUMBERED XXXA, XXXB, XXXC ETC. EXAMPLE: PARALLEL
INSTRUMENTS SHALL BE NUMBERED 017A, 017B & 017C.
UIC
IC
VIS
-
FIC
PDG
FFS
KIC
AIK
-
LIS
1
FZ
MRC
AY
ANALYZERS MAY BE FURTHER IDENTIFIED BY DESCRIPTIVE LETTERS OR
WORDS WRITTEN OUTSIDE THE TAGGING BALLOON.
FF
PIT
-
LC-
HS - HAND SWITCH OR PUSH BUTTON
QZ
SAL
PDCV
SOLENOID VALVE COIL
TE
-
EXAMPLE
UI
IAL
VIK
-
ESL
FFT
KI
O-
AIC
CE
LIK
TD
FFZ
MRT
AV
A-
PRS
-
N-
IDENTIFICATION LETTERS:
INSTRUMENT
ON LOCAL
PANEL
L
SA
TC
GSL
-
WIT
Q
IA
JC
ES
5. ALL CONTACTS THAT REQUIRE ANNUNCIATOR POINTS
AND/OR VALVE STATUS LIGHTS SHALL BE EITHER
DOUBLE-POLE FOR INTERLOCK AND THE OTHER FOR
ANNUNCIATOR OR STATUS LIGHT, OR DIRECT INPUT TO
PLC WITH REPEATED OUTPUT TO AUXILIARY DEVICE.
N-
FFV
KG
AI
CC
LIC
IS USED WITH T AS TW FOR TEMPERATURE WELL.
MIS
PDS
AX
THE COMBINATION OF LETTERS SHOWN INCLUDE THOSE MOST FREQUENTLY ENCOUNTERED. OTHER COMBINATIONS MAY BE DERIVED FROM TABLE 1 ISA-S-5.1
STANDARD. IF AN INSTRUMENT HAS ADDITIONAL FUNCTIONS, IT SHOULD BE SHOWN BY TWO GROUPS OF LETTERS RATHER THAN EXCEEDING THREE LETTERS
(E.G. FQI AND FRC NOT FQIRC).
PRC
TYPICAL CUTBACK CONTROL REPRESENTATION SEE APPLICABLE
P&ID FOR COMPLETE INTERACTION.
-
EIS
SZ
NUMBER DISPLAYED IN A SQUARE
REPRESENTS THE STEP NUMBER
SHOWN ON THE SQUENCE STEP INDICATOR.
TAL
GS
IZ
PD
TDS
- RELIEF VALVE (SYMBOL REF. DWG. 245.0000.000.041.001)
JAL
J
ET
FFY
KE
-
CAL
LI
W-
MIK
AT
DSL
PDT
PRT
9.
FQC
XSL
- INDICATING LIGHT
-
CB-
NUMBER DISPLAYED IN OR NEXT TO
A SYMBOL REPRESENTS THE LOGIC
GATE NUMBER.
VIC
GT
P
-
- EXCESS FLOW VALVE
JA
EV
L
3. LOGIC SYMBOLS REPRESENT FUNCTIONAL AND
OPERATIONAL SEQUENCE OF EVENTS AND DO NOT
NECESSARILY REFLECT ACTUAL LOGIC GATES.
SNAP
FFX
KC
AE
CA
LG
DC
MIC
PDV
ASL
DS
TIME OR TIME
SCHEDULE
PIS
SOLENOID VALVES ON EMERGENCY SYSTEMS SHOULD BE TAGGED AS *YE-XXX, I.E. XYE-001.
SOLENOID VALVES ON NON-EMERGENCY SYSTEMS SHOULD BE TAGGED AS *YI-XXX, I.E. LYI-001.
XS
RUN
TDY
FQA
-
WILL BE USED FOR DIGITAL INPUT/OUTPUT TO MICROPROCESSOR BASED SYSTEMS.
- I.E.- MECHANICAL EQUIPMENT ON/OFF MANUAL CONTROL OR EQUIPMENT STATUS-
RUN/STOP.
FUNCTIONAL LOGIC DIAGRAMS
GV
INSTRUMENT IDENTIFICATION_NUMBERS
INSTRUMENTS SYMBOLS
HSL
M
- PRESSURE SAFETY VALVE
JZ
K
EY
2. ALL ELECTRICALLY AND ELECTRONIC CONTROLLED
DEVICES ARE SHOWN IN THE DE - ENERGIZED
CONDITION PRIOR TO START-UP POSITION, UNLESS
OTHERWISE SPECIFICALLY NOTED.
FFR
KAL
IS ALSO USED TO MEAN SAFETY AS IN PSE RUPTURE DISC.
-
LE
DAL
MI
AS
DT
POWER
PDY
PIK
8 .
XT
LP
TA
WILL BE USED OUTSIDE BALLOON TO IDENTIFY INSTRUMENT AT LOCAL CONSOLES.
LEGEND FOR
GY
DCS STATUS LIGHT
-
HS
- RUPTURE DISC
-
EX
1. GRAPHICS LOGIC SHOWN ON DWGS. CONFORM TO ISA
GRAPHIC SYMBOLS.
S-
FFIT
FQS
KA
AAL
INDICATOR
LC
DA
-
TDX
A
DV
CURRENT
PIC
SOLENOID VALVES ON NON- EMERGENCY SYSTEMS SHOULD BE TAGGED AS UYI- XXX.
XV
- ILLUMINATED PUSH BUTTON
WITH STOP ACTION
LOCAL PANEL MOUNTED
PDIC
QSL
GX
DCS ALARM
-
ZSL
- SIGHT FLOW GLASS
ISL
I
EZ
DIAGRAMS
FQT
KZ
IS USED AS A MEASURED VARIABLE FOR RADIOACTIVITY MEASUREMENT.
AA
LAL
PDIK
WIS
D
D, F, Q,-
ME
DY
PI
CUT BACK CONTROL
7.
XY
LP
GR
PDIS
ANNUCIATOR [STANDARD]
ZS
HV
- PURGEMETERS
IS
ER
H
FUNCTIONAL LOGIC
FQV
-
FFIS
VI
AC
PDX
LA
WIK
CRS
MC
DX
PG
C
FRONT PANEL
INSTRUMENT
PDIT
XX
STOP
HAND
- WITH VENDOR SUPPLIED EQUIPMENT
GIT
MISCELLANEOUS
ANNUNCIATOR [FIRST OUT]
HY
ZT
- LEVEL GAUGES
EIK
IT
UC
EIT
GENERAL NOTES FOR
FQY
JSL
U-
VG
FFIK
PDR
LZ
WIC
CZ
MAL
DZ
PE
BZ
HIGH PRESSURE
SHUTDOWN
SWITCH
6.
XR
- SOFT HAND SWITCH OR
PUSH BUTTON WITH
RUN/STOP ACTION
AND RUN STOPPED STATUS DISPLAY
CONDUCTIVITY
GAUGING
POSITION
PDRS
CONTROL VALVE OR DAMPER
- RESISTANCE TEMPERATURE DETECTOR
GRS
RESISTOR
ZV
HX
- TEMPERATURE TEST WELL
TZ
EIC
IV
ERS
UAL
-
SIGNAL INVERTER
IS USED FOR PILOT LGHT. THE LETTER "L" MAY BE USED ALONE
OR IF PART OF A LOOP, IT CAN TAKE THE LOOP LETTERS AS A PREFIX.
E.G.F. , ETC.
FQX
JS
FFIC
VE
-
WI
CY
MA
DIS
4.
BY
MULTIFUNCTION
LOGIC FOR
EMERGENCY
SYSTEMS
PDRT
XIT
R/S
BURNER FLARE
FLOW TOTAL
DIK
TDIT
-
IS USED WITH ZSC TO GIVE CLOSED POSITION.
LCV
FFI
PA
HARDWIRED INTERLOCK SYSTEM
XE
FR
-
CRC
HOA
-
ELECTRICAL ACCESSORIES, COIL RELAYS, AMPLIFIERS AND I/P TRANSDUCERS AT
CONTROL VALVES, ARE NORMALLY OMITTED ON THE P&ID. THE LATTER MAY
BE SHOWN FOR THE LOOPS, WITH TWO OR MORE VALVES OR SEPARATE DEVICES, OR
WITH THE AIR SIGNAL GOING TO AN INSTRUMENT PRIOR TO THE VALVE.
THE IDENTIFICATION NUMBER FOR LOOPS WILL HAVE SIX DIGITS, THE FIRST THREE BEING UPGRADER COMPLEX UNIT NUMBER.
SNAP ACTING
RELAY ON TEMP.
TRIP SYSTEM
4. STATE OF LOGIC IS SHOWN AT LOGIC "0" WITH POWER OFF
AND ALL INPUTS AND OUTPUTS IN THE FAIL SAFE CONDITION.
THE FOLLOWING THREE DIGITS WILL PROVIDE A SINGLE SEQUENCE OF LOOP NUMBERS FOR EACH PROCESS VARIABLE
IDENTIFICATION OF EACH LOOP.
HOA - LOCAL HAND-OFF-AUTO
TO MOTOR
(ONE BALLOON CAN REPRESENT MORE
THAN ONE FUNCTION)
THE LOOP NUMBERING SEQUENCE WILL BEGIN WITH THE NUMBER 001 FOR EACH PROCESS VARIABLE IDENTIFICATION FOR
EACH UNIT, INCLUSIVE OF THE FOLLOWING LOCAL INSTRUMENTS.
LETTER DISPLAYED IN A DIAMOND
REPRESENTS AN EXTERNAL CONNECTION
BETWEEN THE LOAD SIDE OF AN OUTPUT
MODULE AND THE LINE SIDE OF AN
INPUT MODULE FOR TRIAC FAILURE
DETECTION.
THE FIRST THREE DIGITS (UNIT NUMBER) WILL BE OMITTED FROM THE BALLOONS FOR IMPROVED READABILITY OF LOOP
IDENTIFICATION NUMBERS. A GENERAL NOTE ON THE P&ID WILL REFERENCE THIS AND IDENTIFY THE OMITTED PLANT NUMBER.
THE INSTRUMENT LOOP NUMBERS WILL THEN BE THREE DIGITS, I.E. 017.
IF MEASUREMENT POINT HAS A LOGIC INTERLOCK; THE INDICATED VALUE WILL BE AVAILABLE
IN THE DCS. THE LL OR HH SIGNIFIES THE TRIP ACTION UNDER ENGINEERING CONTROL,
WHICH THE OPERATOR CANNOT ADJUST.
IS USER'S CHOICE - EITHER AS A MEASUREMENT OR OUTPUT FUNCTION.
INTERLOCK NUMBERS ARE SIX DIGITS AND ARE ASSIGNED BY THE INSTRUMENT DEPARTMENT. THE FIRST THREE DIGITS DESIGNATE
THE UNIT AND THE LATTER THREE ARE SEQUENTIAL, COMMENCING AT 001 IN EACH UNIT. THE FIRST THREE DIGITS ARE OMITTED ON
THE P&ID.
IS USED WITH F TO GIVE FO, FLOW ORIFICE RESTRICTION.
IS USED WITH ZSO TO GIVE OPEN POSITION.
* - E SYMBOL USED WHEN TRACING POWER COMES FROM
EMERGENCY SYSTEM.
1. THE SWITCH/LIGHT FUNCTION SHALL BE SHOWN OUTSIDE OF CIRCLE
IS USED TO SHOW ON/OFF TYPE NON ADJUSTABLE RELAYS IN A LOOP.
- I.E.- SOLENOIDS, PNEUMATIC 3-WAY VALVES ETC.
ARE MODIFYING LETTERS FOR DIFFERENCE (D), FRACTION OR RATIO (F),
AND QUALITY OR TOTAL (Q). THEY MAY BE USED WITH OTHER FIRST
LETTERS THAN THOSE SHOWN IN THE TABLE , E.G. KQ-TOTAL TIME,
SD-SPEED DIFFERENCE, DF DENSITY RATIO.
WILL BE USED OUTSIDE BALLOON TO IDENTIFY INSTRUMENTS AT LOCAL PANELS.
IF MORE THAN ONE PANEL, THEN IDENTIFY THEM NUMERICALLY AND
REFERENCE IN GENERAL NOTES.
SIK
JRC
RECORDING TRANSMITTER
FUNCTION IN DCS SYSTEM
NOT REQUIRED TO BE
DISPLAYED TO OPERATE
RELAY
4. FOR MOTOR CONTROL SWITCHES AND LIGHTS, ONLY PANEL MOUNTED ITEMS ARE SHOWN
ON P&ID'S EXCEPT WHERE LOCAL DEVICES ARE OTHER THAN START/STOP.
ALL LOCAL DEVICES ARE THE RESPONSIBILITY OF THE ELECTRICAL DEPT.
EE
THE BALLOONS MAY BE DRAWN TANGENTIALLY TO SHOW A COMMON INSTRUMENT WHERE PRACTICAL.5.
LP
OR
AND
AND
OR
-
-
A 05/08/10 ISSUED FOR REVIEW
SHELL DWG NO.: REV.
SHELL CANADA
SCALE: NONE
REV
DATE
DESCRIPTION
ISSUED
C
D
A
B
4 3 2 1
4 3 2 1
C
D
CLIENT
APP
PEMAPE
MC
PDPCSPRSCKDBY
QUEST CCS PROJECT
PIPING AND INSTRUMENT DIAGRAM
QUEST CCS PROJECT
R
E
E
002
I
001
I
001
I
2
0
0
.
0
0
8
F
I
L
E
:
\
\
F
:
\
1
0
2
5
\
D
R
A
W
I
N
G
S
\
U
T
I
L
I
T
I
E
S
\
2
0
0
\
2
0
0
.
0
0
8
.
p
i
d
M
O
D
E
L
D
A
T
E
:
2
/
1
/
2
0
1
1
4
:
2
2
:
3
1
P
M
B
Y
:
a
h
m
1
4
8
8
7
A
INSTR ID LETTERS SYMBOLS AND LOOP NO
UNIT 200 - COMMON
200.0000.000.041.008
8
AUXILIARY LOCATION
NORMALLY INACCESSIBLE
TO AN OPERATOR
FO - FLOW ORIFICE