* Marlin 3D Printer Firmware
* Copyright (c) 2020 MarlinFirmware [https://github.com/MarlinFirmware/Marlin]
*
* Based on Sprinter and grbl.
* Copyright (c) 2011 Camiel Gubbels / Erik van der Zalm
*
* This program is free software: you can redistribute it and/or modify
* it under the terms of the GNU General Public License as published by
* the Free Software Foundation, either version 3 of the License, or
* (at your option) any later version.
*
* This program is distributed in the hope that it will be useful,
* but WITHOUT ANY WARRANTY; without even the implied warranty of
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
* GNU General Public License for more details.
*
* You should have received a copy of the GNU General Public License
* along with this program. If not, see <https://www.gnu.org/licenses/>.
*
*/
#pragma once
/**
* Configuration_adv.h
*
* Advanced settings.
* Only change these if you know exactly what you're doing.
* Some of these settings can damage your printer if improperly set!
*
* Basic settings can be found in Configuration.h
*/
#define CONFIGURATION_ADV_H_VERSION 020008
//===========================================================================
//============================= Thermal Settings ============================
//===========================================================================
// @section temperature
/**
* Thermocouple sensors are quite sensitive to noise. Any noise induced in
* the sensor wires, such as by stepper motor wires run in parallel to them,
* may result in the thermocouple sensor reporting spurious errors. This
* value is the number of errors which can occur in a row before the error
* is reported. This allows us to ignore intermittent error conditions while
* still detecting an actual failure, which should result in a continuous
* stream of errors from the sensor.
*
* Set this value to 0 to fail on the first error to occur.
*/
#define THERMOCOUPLE_MAX_ERRORS 15
//
// Custom Thermistor 1000 parameters
//
#if TEMP_SENSOR_0 == 1000
#define HOTEND0_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND0_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND0_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_1 == 1000
#define HOTEND1_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND1_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND1_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_2 == 1000
#define HOTEND2_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND2_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND2_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_3 == 1000
#define HOTEND3_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND3_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND3_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_4 == 1000
#define HOTEND4_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND4_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND4_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_5 == 1000
#define HOTEND5_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND5_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND5_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_6 == 1000
#define HOTEND6_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND6_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND6_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_7 == 1000
#define HOTEND7_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define HOTEND7_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define HOTEND7_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_BED == 1000
#define BED_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define BED_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define BED_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_CHAMBER == 1000
#define CHAMBER_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define CHAMBER_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define CHAMBER_BETA 3950 // Beta value
#endif
#if TEMP_SENSOR_PROBE == 1000
#define PROBE_PULLUP_RESISTOR_OHMS 4700 // Pullup resistor
#define PROBE_RESISTANCE_25C_OHMS 100000 // Resistance at 25C
#define PROBE_BETA 3950 // Beta value
#endif
//
// Hephestos 2 24V heated bed upgrade kit.
// https://store.bq.com/en/heated-bed-kit-hephestos2
//
//#define HEPHESTOS2_HEATED_BED_KIT
#if ENABLED(HEPHESTOS2_HEATED_BED_KIT)
#undef TEMP_SENSOR_BED
#define TEMP_SENSOR_BED 70
#define HEATER_BED_INVERTING true
#endif
//
// Heated Bed Bang-Bang options
//
#if DISABLED(PIDTEMPBED)
#define BED_CHECK_INTERVAL 5000 // (ms) Interval between checks in bang-bang control
#if ENABLED(BED_LIMIT_SWITCHING)
#define BED_HYSTERESIS 2 // (°C) Only set the relevant heater state when ABS(T-target) > BED_HYSTERESIS
#endif
#endif
//
// Heated Chamber options
//
#if TEMP_SENSOR_CHAMBER
#define CHAMBER_MINTEMP 5
#define CHAMBER_MAXTEMP 60
#define TEMP_CHAMBER_HYSTERESIS 1 // (°C) Temperature proximity considered "close enough" to the target
//#define CHAMBER_LIMIT_SWITCHING
//#define HEATER_CHAMBER_PIN 44 // Chamber heater on/off pin
//#define HEATER_CHAMBER_INVERTING false
//#define CHAMBER_FAN // Enable a fan on the chamber
#if ENABLED(CHAMBER_FAN)
#define CHAMBER_FAN_MODE 2 // Fan control mode: 0=Static; 1=Linear increase when temp is higher than target; 2=V-shaped curve.
#if CHAMBER_FAN_MODE == 0
#define CHAMBER_FAN_BASE 255 // Chamber fan PWM (0-255)
#elif CHAMBER_FAN_MODE == 1
#define CHAMBER_FAN_BASE 128 // Base chamber fan PWM (0-255); turns on when chamber temperature is above the target
#define CHAMBER_FAN_FACTOR 25 // PWM increase per °C above target
#elif CHAMBER_FAN_MODE == 2
#define CHAMBER_FAN_BASE 128 // Minimum chamber fan PWM (0-255)
#define CHAMBER_FAN_FACTOR 25 // PWM increase per °C difference from target
#endif
#endif
//#define CHAMBER_VENT // Enable a servo-controlled vent on the chamber
#if ENABLED(CHAMBER_VENT)
#define CHAMBER_VENT_SERVO_NR 1 // Index of the vent servo
#define HIGH_EXCESS_HEAT_LIMIT 5 // How much above target temp to consider there is excess heat in the chamber
#define LOW_EXCESS_HEAT_LIMIT 3
#define MIN_COOLING_SLOPE_TIME_CHAMBER_VENT 20
#define MIN_COOLING_SLOPE_DEG_CHAMBER_VENT 1.5
#endif
#endif
/**
* Thermal Protection provides additional protection to your printer from damage
* and fire. Marlin always includes safe min and max temperature ranges which
* protect against a broken or disconnected thermistor wire.
*
* The issue: If a thermistor falls out, it will report the much lower
* temperature of the air in the room, and the the firmware will keep
* the heater on.
*
* The solution: Once the temperature reaches the target, start observing.
* If the temperature stays too far below the target (hysteresis) for too
* long (period), the firmware will halt the machine as a safety precaution.
*
* If you get false positives for "Thermal Runaway", increase
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 40 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 10 // Degrees Celsius
//#define ADAPTIVE_FAN_SLOWING // Slow part cooling fan if temperature drops
#if BOTH(ADAPTIVE_FAN_SLOWING, PIDTEMP)
//#define NO_FAN_SLOWING_IN_PID_TUNING // Don't slow fan speed during M303
#endif
/**
* Whenever an M104, M109, or M303 increases
评论1