MIL-DTL-16878/3
For internal wiring of meters, panels and electronic
equipment . Formerly “Type D.”
Electronic Hookup Wire
• Vinyl Primary Insulation
• Nominal .031” WALL
(No Outer Covering)
• -54ºC to +105ºC
• 3000 Volts. R.M.S. (working)
Meets UL Styles 1011, 1013, 1015 and CSA TR-32
or TEW except where noted.
GAUGE
(AWG)
PART
NO.
MIL-SPEC
PART NO.
NUMBER
OF
STRANDS
(AWG)
GAUGE OF
STRANDS
(AWG)
NOM. DIAM.
OF STRANDED
CONDUCTOR
IN. mm
NOM. FIN.
WIRE DIAM.
IN. mm
MAX. RESISTANCE
(dc at 20º C) Ω /per
1000-ft Km
NOM. WT.
LBS per
1000-ft Kg/Km
24 ND124U M16878/3 BEA 1 24 .0201 .511 .082 2.08 27.2 89 4.2 6.25
24 ND732U M16878/3 BEB 7 32 .0240 .610 .086 2.18 26.2 86 4.0 5.95
24 ND1936U M16878/3 BEE 19 36 .0240 .610 .086 2.18 25.4 83 4.1 6.10
22 ND122U M16878/3 BFA 1 22 .0253 .643 .088 2.24 17.2 56 5.0 7.44
22 ND730U M16878/3 BFB 7 30 .0300 .762 .092 2.34 16.7 55 5.2 7.74
22 ND1934U M16878/3 BFE 19 34 .0300 .762 .092 2.34 15.9 52 5.3 7.88
20 ND120U M16878/3 BGA 1 20 .0320 .813 .094 2.39 10.7 35 6.8 10.11
20 ND728U M16878/3 BGB 7 28 .0380 .965 .100 2.54 10.4 34 7.3 10.86
20 ND1932U M16878/3 BGE 19 32 .0380 .965 .100 2.54 9.76 32 7.3 10.86
18 ND118U M16878/3 BHA 1 18 .0403 1.02 .102 2.59 6.78 22 9.3 13.84
18 ND726U M16878/3 BHB 7 26 .0480 1.22 .110 2.79 6.54 21 9.7 14.43
18 ND1930U M16878/3 BHE 19 30 .0480 1.22 .110 2.79 6.22 20 10.0 14.88
16 ND116U M16878/3 BJA 1 16 .0508 1.29 .113 2.87 4.26 14 12.6 18.75
16 ND1929U*† M16878/3 BJE 19 19 .0540 1.37 .116 2.95 4.82 16 12.0 17.86
16 ND2630U M16878/3 BJF 26 30 .0550 1.40 .117 2.97 4.59 15 12.5 18.60
14 ND114U M16878/3 BKA 1 14 .0641 1.63 .126 3.20 2.68 9 16.9 25.15
14 ND1927U*† M16878/3 BKE 19 27 .0690 1.75 .131 3.33 3.05 10 17.1 25.44
14 ND4130U M16878/3 BKH 41 30 .0710 1.80 .134 3.40 2.94 9.6 17.9 26.64
12 ND1925U*† M16878/3 BLE 19 25 .0890 2.26 .161 4.09 1.92 6.3 27.4 40.77
12 ND3728U* M16878/3 BLG 37 28 .0890 2.26 .156 3.96 2.01 6.6 28.9 43.00
12 ND6530U M16878/3 BLJ 65 30 .0890 2.26 .165 4.19 1.85 6.1 28.5 42.41
10 ND3726U* M16878/3 BMG 37 26 .1070 2.72 .178 4.52 1.26 4.1 38.6 57.44
8 ND13329U* M16878/3 BNL 133 29 .1670 4.24 .244 6.20 .701 2.3 70.5 104.90
6 ND13327* M16878/3 BPL 133 27 .2100 5.33 .290 7.37 .444 1.4 104.0 154.75
4 ND13325U* M16878/3 BRL 133 25 .2660 6.76 .351 8.92 .280 0.9 154.0 229.15
2 ND66530U* M16878/3 BSP 665 30 .3420 8.69 .425 10.80 .183 0.6 231.0 343.73
1 ND81730U* M16878/3 BTR 817 30 .3820 9.70 .475 12.07 .149 0.5 284.0 422.59
1/0 ND104530U* M16878/3 BUS 1045 30 .4310 10.95 .530 13.46 .116 0.4 361.0 537.17
* Not C.S.A. Certified
† Not U.L. Recognized
Thermoplastic Tinned Copper
Insulation Stranded
Standard basic insulation color numbers are: Black: 0, Brown: 1, Red: 2, Orange: 3, Yellow: 4, Green: 5, Blue: 6, Violet: 7, Gray: 8, White: 9. The
insulation color code number, per MIL-STD-681, may be 1, 2 or 3 digits depending on the number or absence of stripes. The 1st number is color of
Insulation, 2nd number is color of first stripe; 3rd number is color of the second stripe. Example: White wire(9) + Red stripe(2) + Black stripe(0) makes a
color code number of “920”. That color number, “920” is appended to the part number. Sample part number might be “xxxxxx-xxx-920”
Military Voltage Rating 3000 volts.
Sine-wave Spark-Test Voltage 8000 VAC.
Impulse Spark Test Voltage 12000 V pulse-peak, or 8500 V @3 kHz
Insulation Breakdown Voltage > 12,000 volts, peak.
IR: Insulation Resistance, wet > 2900 megohm/100 meter, metal to water bath at +20ºC
Nominal Dielectric Constant value 4.
Flame Properties Self extinguishing. Meets UL VW-1
Cold Bending for gauges 32 to 22 Bends over 2 inch mandrel while at -54ºC.
Cold Bending for gauges 20 to -14 Bends over 3 inch mandrel while at -54ºC.
Fungus Fungus Resistant
1-3
NATIONAL WIRE & CABLE custom cable manufacturing & molding • www.nationalwire.com Order Desk 323-225-5611