Dynagen README
Interim Version 0.11.0-080414
For documentation, refer to the tutorial in the docs directory, and the sample network files in the sample_labs directory. To see usage examples for all options, refer to the "all_config_options.txt" file in the sample_labs directory. Also be sure to visit the Dynamips web site at http://www.ipflow.utc.fr/index.php/Cisco_7200_Simulator.
This version of Dynagen requires at least version 0.2.8-RC1 of Dynamips. The Windows installer package requires at least Windows XP SP2. For earlier versions of Windows, replace the Dynamips binary with the Windows 2000 version as described in the Dynagen FAQ section of the tutorial.
Known Issues
============
* "save" and "idlepc save" commands may reformat the indentation of your network file and add an explicit "model" definition in the router section
* Gig interfaces on the NPE-G2 cannot currently be used.
Changelog
=========
Version 0.11.0
* Merge of the features of confDynagen (dynamic reconfiguration, pemu support, and many other features). Big thanks to Pavel Skovajsa for performing the merge work and other significant contributions.
* Addition of a pemu server for Cisco PIX emulation. Thanks to Thomas Pani for writing the wrapper, and to mmm123 for writing pemu. NOTE: A Pemu instance will always consume 100% of a CPU core. There is no "idlepc". Use a tool like BES (Windows) or cpulimit (Linux) if you wish to reduce CPU usage.
* Could not specify a model of 1751 or 1760 in a router definition
* WIC interfaces on 1751s and 1760s could not be used
* On Windows platforms, Network Device list changes to the temp dir before executing Dynamips (helps Vista users).
* Added a delay option to start /all. This introduces a pause between starting devices.
* Filter command was broken in 0.10.x
* FS#217 - fixed the connect method for switches. Only effected 3rd party developers using the library, Dynagen does not use these methods.
* FS#211 - Dynagen crash when specifying invalid port
* 7200 instances now default to using an NPE-400 rather than an NPE-200. This is because the C7200-IO-2FE is not compatible with the NPE-200 and this was causing confusion. You can override this new behavior with "npe = NPE-200".
* Referencing f0/0 or f0/1 with 7200s now automatically inserts a C7200-IO-2FE in slot 0 rather than a C7200-IO-FE. You can override this behavior by specifying "slot0=PA-C7200-IO-FE".
* Support for ATM to Ethernet bridge introduced in Dynamips 0.2.8-RC2. Provision using ATMBR.
* idlemax issue fixed (see http://7200emu.hacki.at/viewtopic.php?p=13676)
* Resolves crash when invalid port specified on adapter (http://7200emu.hacki.at/viewtopic.php?p=15685)
* Dynagen now warns if a router does not have an image set
* The prefix "PA-" for the 7200 IO adapters is optional (i.e. "PA-C7200-IO-2FE" or "C7200-IO-2FE").
* Multisever config with two instances on the same system no longer requires use of the UDP configuration option workaround.
* The adapter "PA-4T+" should now be specified as "PA-4T+". "PA-4T" is still supported so as not to break compatibility with existing labs.
* Added a "start-pemu.sh" script to launch pemuwrapper, writing temp files to a temp directory. To be used on Linux systems.
* Throws a warning for the infamous "using localhost with multiserver" misconfiguration.
* Change of base udp port for pemuwrapper to 40000 so that we do not conflict with vpc
* "idlepc show" now shows the current idlepc value if one has already been applied
* idlepc commands now warn that pemu instances are not supported
* Added "ghostsize" command to dynamic configuration mode
* Ignores GNS3-DATA section. Caution: Issuing a "copy run start" from inside of Dynagen will obliterate this section.
Interim build updates:
0.11.0-080414:
* Fix for IOS ghosting bug detailed here: http://7200emu.hacki.at/viewtopic.php?p=21144
0.11.0-080411
* Added "ghostsize" command to dynamic configuration mode
* Ghostios and dynamic configuration mode bugfixes
* Ignores GNS3-DATA section. Caution: a "copy run start" will obliterate this section. This will be fixed in the future.
0.11.0-080407
* "idlepc show" now shows the current idlepc value if one has already been applied
* idlepc commands now warn that pemu instances are not supported
0.11.0-080328
* Throws a warning for the infamous "using localhost with multiserver" misconfiguration.
* Change of base udp port for pemuwrapper to 40000 so that we do not conflict with vpc
* Changed the interim build versioning scheme (sorts better)
0.11.0-031408
* 2611XM was unusable in some circumstances
* Fixed bug which prevented the automatic selection of 2 WIC-2T wics in the same router
0.11.0-030208
* NPE-400 is default NPE for 7200 instances
* Silently ignore x & y options for files generated by GNS3
* iomem option was never put in the running_config.
* Corrected problems with nio_null.
* Fix for automatic UDP bug with single-host multiserver config
* Added some code for firewalls settings to be put in running_config like routers
* Wrong parameters for the atm_unconfigure command
* RAM option with pemu raised a "numbers of parameters" error because of a leading space.
0.11.0-020108
* Fixes for conf mode multiserver udp collision and "no slot" issues.
0.11.0-012708
* Fix for conf mode disconnecting links bug (e.g. "no f0/0 = R1 f0/0")
0.11.0-011208
* Fix for broken export (http://7200emu.hacki.at/viewtopic.php?t=4865)
* patch for 'unconnected frsw port handling' (general case for all switches)
* Fix for pemuwrapper FLASH format issue (http://7200emu.hacki.at/viewtopic.php?p=17387)
* Fix for PIX autostart bug (http://7200emu.hacki.at/viewtopic.php?t=4929)
0.11.0-010308
* fix for "unconnected frsw port handling" bug
0.11.0-121507
* "idlepc show" for firewall devices caused crash
* "conf <hypervisor>" caused crash when hypervisor did not exist
Version 0.10.1
* Accidentally only gave the NM-16ESW 15 interfaces.
Version 0.10.0
* Support for the 1700 platform new to Dynamips 0.8.0-RC1. See the tutorial for supported platforms and modules.
* Support for WIC-1T, WIC-2T, and WIC-1ENET. See the tutorial for supported router platforms and usage.
* Support for NM-CIDS and NM-NAM. Note these are just "stubs" (at least as of this version of Dynamips). You can connect to them using "IDS-Sensorx/0 = ..." or "Analysis-Modulex/0 = ..." but they don't actually do anything. See the tutorial for platform support.
* FS#154 - added "confreg" command to set the configuration register of router(s) from Dynagen. e.g. "confreg r1 0x2142" followed by "reload r1". Note changes to the config register will not be displayed in a "show ver" until the router is reloaded.
* FS#182 - Second port of PA-C7200-IO-2FE was not usable
* FS#177 - crash on malformed interface entry in net file
* Dynagen now automatically picks a PA-2FE-TX rather than a PA-FE-TX when referencing a FastEthernet on ports 1-6 on a 7200. You can override this to mimic the old behavior with "slotx = PA-FE-TX".
* the vbs file that launches SecureCRT sessions was missing from the Windows installer package
* Changed the state shown with the "list" command for virtual switches from "n/a" to "always on" to avoid confusion.
* Added an up-to-date list of hardware emulated by Dynamips to the tutorial. Thanks to ggee for performing the initial documentation in this post: http://7200emu.hacki.at/viewtopic.php?t=1831
Version 0.9.3
* No longer prints a warning for unused switchports
* Added "MAC" option to set base MAC address of a router. See all_config_options.txt for usage.
* Eliminated unnecessary Leopard-2FE insertion on 3660s resulting in "a NM already exists in slot 0" warnings from Dynamips.
* Fix bug that caused crash when trying to capture packets on an unconnected interface
* Dynamips temp files are now written to the user's temp dir rather than \Program Files\Dynamips. Might make it work better under
没有合适的资源?快使用搜索试试~ 我知道了~
资源推荐
资源详情
资源评论
收起资源包目录
工大瑞普cisco模拟器资源包 (146个子文件)
ccnp_stad_reg.net.bak 4KB
ccna_sw.net.bak 2KB
PIM-DM.bmp 3.11MB
UPGRADE.cmd 1KB
copyright.cmd 919B
2.修改网卡参数.cmd 754B
4.修改UDP端口.cmd 415B
3.修改连接端口.cmd 409B
2K-7203.cmd 388B
2K-7201.cmd 388B
2K-7202.cmd 388B
XP-7203.cmd 386B
XP-7202.cmd 386B
XP-7201.cmd 386B
1720_拓扑示例.cmd 359B
8.控制台SP-PIX.cmd 346B
0.虚拟服务Dynamips-WIN2000.cmd 325B
0.虚拟服务Dynamips-XP&2003.cmd 323B
2.CCIE-RS实验环境一.cmd 311B
0.虚拟服务Dynamips-WIN2000.cmd 305B
0.虚拟服务Dynamips-XP2003.cmd 303B
2.NA路由综合实验一.cmd 301B
0.虚拟服务Dynamips-XP&2003.cmd 296B
0.虚拟服务Dynamips-WIN2000.cmd 296B
11.控制台_可保存.cmd 282B
4.控制台NP迷你版.cmd 275B
1.控制台NA路由版.cmd 274B
10.控制台FTP_VPN.cmd 273B
3.控制台NP标准版.cmd 273B
1.安装Win_Pcap.cmd 272B
6.控制台NP-ADSL.cmd 271B
2.控制台NA标准版.cmd 271B
5.控制台NA交换版.cmd 269B
7.控制台NPSP-VPN.cmd 265B
9.控制台PIM-DM.cmd 264B
0.虚拟服务PEMU-PIX.cmd 249B
configspec 2KB
COPYING 18KB
list.cpp 45KB
wndproc.cpp 41KB
tooltips.cpp 29KB
hack.cpp 25KB
Copy of hack.cpp 24KB
misc.cpp 16KB
ini.cpp 12KB
watch.cpp 10KB
skin.cpp 8KB
sstp.cpp 5KB
log.cpp 5KB
main.cpp 3KB
NotifyIcon.cpp 2KB
Thumbs.db 41KB
cygwin1.dll 1.78MB
cygwin1.dll 1.78MB
php4ts.dll 1.39MB
MSVCR71.dll 340KB
BES.dsp 6KB
BES.dsw 531B
pemuwrapper.exe 5.78MB
dynagen.exe 5.07MB
dynamips-wxp.exe 822KB
dynamips-w2000.exe 821KB
WinPcap_4_1_beta.exe 550KB
putty.exe 348KB
BES.exe 180KB
BES.exe 140KB
Dymem.exe 88KB
php.exe 24KB
nvram_export.exe 6KB
FLASH 16MB
FLASH 16MB
FLASH 16MB
CCNP标准迷你版.gif 77KB
1.NA路由综合实验一.gif 62KB
CCSP-PIX.gif 62KB
CCNA交换版.gif 60KB
1720_拓扑示例.gif 54KB
CCNA标准版.gif 53KB
VPN.gif 51KB
CCNP-ADSL.gif 50KB
CCNA路由版.gif 48KB
strings.utf8.h 16KB
BattleEnc.h 14KB
resource.h 5KB
sstp.sjis.h 667B
readme.html 24KB
active.ico 2KB
active.ico 2KB
idle.ico 2KB
dynagen.ini 2KB
bes.ini 264B
idlepc.ini 225B
pemu.ini 97B
pemu.ini 97B
pemu.ini 97B
bes_sw.ini 30B
1.CCIE-RS实验环境一.jpg 164KB
bes4.jpg 75KB
bes1.jpg 71KB
defskin.jpg 56KB
共 146 条
- 1
- 2
资源评论
she2004
- 粉丝: 2
- 资源: 39
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功