没有合适的资源?快使用搜索试试~ 我知道了~
IEC+61000-4-30-2003/BS+EN+61000-4-30-2003
需积分: 3 0 下载量 99 浏览量
2024-01-03
09:36:58
上传
评论
收藏 709KB PDF 举报
温馨提示
试读
50页
IEC+61000-4-30-2003标准协议
资源推荐
资源详情
资源评论
BRITISH STANDARD
BS EN
61000-4-30:
2003
Incorporating
Corrigendum No. 1
Electromagnetic
compatibility (EMC) —
Part 4-30: Testing and measurement
techniques — Power quality
measurement methods
The European Standard EN 61000-4-30:2003 has the status of a
British
Standard
ICS 33.100.99
12&23<,1*:,7+287%6,3(50,66,21(;&(37$63(50,77('%<&23<5,*+7/$:
Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Mar 17 20:09:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
BS EN 61000-4-30:2003
This British Standard was
published under the authority
of the Standards Policy and
Strategy Committee on
23
June 2003
© BSI 2006
ISBN 0 580 42081 7
National foreword
This British Standard is the official English language version of
EN
61000-4-30:2003, including Corrigendum August 2006. It is identical with
IEC 61000-4-30:2003.
The start and finish of text introduced or altered by corrigendum is indicated
in the text by tags ˜™. Tags indicating changes to CEN text carry the
number of the CEN amendment. For example, text altered by IEC
Corrigendum 1 is indicated in the text by ˆ‰.
The UK participation in its preparation was entrusted by Technical Committee
GEL/210, EMC, to Subcommittee GEL/210/8, EMC — Low frequency
standards, which has the responsibility to:
A list of organizations represented on this subcommittee can be obtained on
request to its secretary.
Cross-references
The British Standards which implement international or European
publications referred to in this document may be found in the BSI Catalogue
under the section entitled “International Standards Correspondence Index”,
or
by using the “Search” facility of the BSI Electronic Catalogue or of
British
Standards Online.
This publication does not purport to include all the necessary provisions of a
contract. Users are responsible for its correct application.
Compliance with a British Standard does not of itself confer immunity
from legal obligations.
— aid enquirers to understand the text;
— present to the responsible international/European committee any
enquiries on the interpretation, or proposals for change, and keep UK
interests informed;
— monitor related international and European developments and
promulgate them in the UK.
Summary of pages
This document comprises a front cover, an inside front cover, the EN title page,
pages 2 to 47 and a back cover.
The BSI copyright date displayed in this document indicates when the
document was last issued.
Amendments issued since publication
Amd. No. Date Comments
16666
Corrigendum No. 1
31 October 2006 See national foreword
Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Mar 17 20:09:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
EUROPEAN STANDARD EN 61000-4-30
NORME EUROPÉENNE
EUROPÄISCHE NORM
April 2003
CENELEC
European Committee for Electrotechnical Standardization
Comité Européen de Normalisation Electrotechnique
Europäisches Komitee für Elektrotechnische Normung
Central Secretariat: rue de Stassart 35, B - 1050 Brussels
© 2003 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC members.
Ref. No. EN 61000-4-30:2003 E
ICS 33.100.99
English version
Electromagnetic compatibility (EMC)
Part 4-30: Testing and measurement techniques –
Power quality measurement methods
(IEC 61000-4-30:2003)
Compatibilité électromagnétique (CEM)
Partie 4-30: Techniques d'essai
et de mesure –
Méthodes de mesure de la qualité
de l'alimentation
(CEI 61000-4-30:2003)
Elektromagnetische Verträglichkeit (EMV)
Teil 4-30: Prüf- und Messverfahren -
Verfahren zur Messung
der Spannungsqualität
(IEC 61000-4-30:2003)
This European Standard was approved by CENELEC on 2003-04-01. CENELEC members are bound to
comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European
Standard the status of a national standard without any alteration.
Up-to-date lists and bibliographical references concerning such national standards may be obtained on
application to the Central Secretariat or to any CENELEC member.
This European Standard exists in three official versions (English, French, German). A version in any other
language made by translation under the responsibility of a CENELEC member into its own language and
notified to the Central Secretariat has the same status as the official versions.
CENELEC members are the national electrotechnical committees of Austria, Belgium, Czech Republic,
Denmark, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Luxembourg, Malta,
Netherlands, Norway, Portugal, Slovakia, Spain, Sweden, Switzerland and United Kingdom.
Incorporating Corrigendum August 2006
Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Mar 17 20:09:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
Foreword
The text of document 77A/398/FDIS, future edition 1 of IEC 61000-4-30, prepared by SC 77A, Low
frequency phenomena, of IEC TC 77, Electromagnetic compatibility, was submitted to the
IEC-CENELEC parallel vote and was approved by CENELEC as EN 61000-4-30 on 2003-04-01.
The following dates were fixed:
– latest date by which the EN has to be implemented
at national level by publication of an identical
national standard or by endorsement
(dop) 2004-01-01
– latest date by which the national standards conflicting
with the EN have to be withdrawn
(dow) 2006-04-01
Annexes designated "normative" are part of the body of the standard.
Annexes designated "informative" are given for information only.
In this standard, annex ZA is normative and annex A is informative.
Annex ZA has been added by CENELEC.
__________
Endorsement notice
The text of the International Standard IEC 61000-4-30:2003 was approved by CENELEC as a
European Standard without any modification.
__________
Page 2
EN 61000−4−30:2003
Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Mar 17 20:09:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
CONTENTS
INTRODUCTION.....................................................................................................................4
1 Scope...............................................................................................................................5
2 Normative references........................................................................................................5
3 Definitions ........................................................................................................................6
4 General ..........................................................................................................................10
4.1 Classes of measurement performance ...................................................................10
4.2 Organization of the measurements.........................................................................10
4.3 Electrical values to be measured............................................................................10
4.4 Measurement aggregation over time intervals ........................................................11
4.5 Measurement aggregation algorithm ......................................................................11
4.6 Time-clock uncertainty...........................................................................................12
4.7 Flagging concept ...................................................................................................12
5 Power quality parameters................................................................................................13
5.1 Power frequency....................................................................................................13
5.2 Magnitude of the supply voltage .............................................................................13
5.3 Flicker ...................................................................................................................14
5.4 Supply voltage dips and swells...............................................................................15
5.5 Voltage interruptions..............................................................................................17
5.6 Transient voltages .................................................................................................18
5.7 Supply voltage unbalance ......................................................................................18
5.8 Voltage harmonics .................................................................................................19
5.9 Voltage interharmonics ..........................................................................................19
5.10 Mains signalling voltage on the supply voltage .......................................................20
5.11 Rapid voltage changes...........................................................................................20
5.12 Measurement of underdeviation and overdeviation parameters...............................20
6 Range of influence quantities and implementation verification .........................................21
6.1 Range of influence quantities .................................................................................21
6.2 Implementation verification ....................................................................................22
Annex A (informative) Power quality measurements – Issues and guidelines.........................24
A.1 Installation precautions ..........................................................................................24
A.2 Transducers ..........................................................................................................27
A.3 Transient voltages and currents .............................................................................30
A.4 Rapid voltage changes...........................................................................................33
A.5 Current ..................................................................................................................33
A.6 Guidelines for contractual applications of power quality measurements ..................36
A.7 Trouble-shooting applications ................................................................................40
A.8 Statistical survey applications ................................................................................41
A.9 Voltage dip characteristics .....................................................................................42
Annex ZA (normative) Normative references to international publications with their
corresponding European publications ....................................................................................45
Bibliography ..........................................................................................................................47
Page 3
EN 61000−4−30:2003
Licensed Copy: Institute Of Technology Tallaght, Institute of Technology, Sat Mar 17 20:09:07 GMT+00:00 2007, Uncontrolled Copy, (c) BSI
剩余49页未读,继续阅读
资源评论
匠心码农
- 粉丝: 1071
- 资源: 51
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功