Jiankun Loginc Analyzer User Guide
http://www.kingst.org
2014-9-15
2
Contents
I、 Overview .......................................................................................................... 4
1、 Basic knowledge ......................................................................................................... 4
2、 Product series .............................................................................................................. 4
3、 Technical specification ............................................................................................... 5
II、 Brief introduction to JkiSuite software ....................................................... 6
1、 How to install the software ......................................................................................... 6
2、 Brief introduction to GUI ........................................................................................... 6
3、 Brief introduction to the demo function ..................................................................... 7
III、 Connect the device ...................................................................................... 9
1、 Connect the device to PC ............................................................................................ 9
2、 Connect device to system under test ........................................................................... 9
3、 Multipoint grounding to increase accuracy .............................................................. 10
IV、 Details of operations ................................................................................... 11
1、 通道设置 Channel settings ........................................................................................ 11
2、 Sample depth and sample rate ................................................................................... 11
3、 Set trigger conditions ................................................................................................ 12
4、 Get the waveform ..................................................................................................... 13
5、 Check and measure the waveform ............................................................................ 14
6、 Data save and export ................................................................................................. 15
7、 Analyze standard protocols ....................................................................................... 16
8、 PWM export ............................................................................................................. 17
V、 Settings for standard protocols .................................................................... 19
1、 UART/RS232/485 .................................................................................................... 19
2、 I2C ............................................................................................................................ 20
3、 SPI ............................................................................................................................ 20
4、 CAN .......................................................................................................................... 21
5、 Simple Parallel .......................................................................................................... 22
6、 1-Wire ....................................................................................................................... 23
7、 DMX-512 ................................................................................................................. 23
8、 UNI/O ....................................................................................................................... 23
9、 User-defined protocol analyzer ................................................................................. 24
Jiankun Loginc Analyzer User Guide
http://www.kingst.org
2014-9-15
3
VI、 FAQs ............................................................................................................. 25
1、 Driver installation fail with the device connected to computer ................................ 25
2、 Identification fail or work unstably with the device connected to the computer ...... 25
3、 Signal glitches appear on individual channels .......................................................... 25
4、 The actual sample time is less than expected when the depth is set to a large value 26
5、 Auto update of the software fails .............................................................................. 26
VII、 contact us ................................................................................................... 27
Jiankun Loginc Analyzer User Guide
http://www.kingst.org
2014-9-15
4
I、 Overview
1、 Basic knowledge
Logic analyzer is the instrument that collects and displays the digital signal from the
devices under test. It is mainly used for timing judgement an analysis. Unlike the oscilloscope
with many voltage grades, It has only two grades(Logic one and Logic zero). .After the
reference voltage is set, the logic analyzer could decide from the test signal that the signal
above the reference voltage is logic one, and the signal below is logic zero. The digital
waveform is formed with 1 and 0. Compared with the oscilloscope, when testing and
measuring the digital systems like MCU, ARM, FPGA and DSP, the logic analyzer could
provide better accuracy, much more data and more complicated measuring methods.
For example, if you are sampling a signal with the logic analyzer, the sample rate of
which is 1Mhz, and the reference voltage is set to 1.5V, the logic analyzer would compare the
current voltage with 1.5V. The signal above 1.5V would be high level(logic 1), and the signal
below 1.5V would be low level(logic 0). Thus we get a sample point, and then we could link
all these points(logic 1 and logic 0) to get a waveform, in which the user could see and analyze
the timing of the signal, logic errors and the relation between each other.
The figure below shows how the logic analyzer samples the signal:
2、 Product series
This product series include LA1016、LA2016、LA5016:
Jiankun Loginc Analyzer User Guide
http://www.kingst.org
2014-9-15
5
3、 Technical specification
Product type
LA1016
LA2016
LA5016
Input
Total number of channels
16
16
16
Max sample rate
100MHz
200MHz
500MHz
Measurement bandwidth
20MHz
40MHz
80MHz
Min pulse captured
20ns
12.5ns
6.25ns
Hardware storage
1Gbits
1Gbits
512Mbits
Hardware Sample depth
50M/channel
50M/ channel
32M/ channel
Max compression depth
10G/ channel
10G/ channel
5G/ channel
Input voltage range
-50V~+50V
-50V~+50V
-50V~+50V
Input impedance
220KΩ, 12pF
220KΩ, 12pF
220KΩ, 12pF
Threshold voltage
≤0.8V low level
≥1.6V high level
≤0.8V low level
≥1.6V high level
≤1.0V low level
≥2.0V high level
PWM
output
Number of channels
2
2
2
Output frequency range
0.1~20MHz
0.1~20MHz
0.1~12.5MHz
Min interval for
frequency adjustment
10ns
10ns
8ns
Min interval for pulse
width adjustment
5ns
5ns
8ns
Output voltage
+3.3V
+3.3V
+3.3V
Export impedance
50Ω
50Ω
50Ω
power
supply
Power supply port
USB2.0/3.0
USB2.0/3.0
USB2.0/3.0
Standby current
130mA
150mA
300mA
Maximum active current
260mA
300mA
550mA
PC
software
Supported protocols
UART(RS-232/485/422)、I2C、SPI、CAN、DMX512、I2S/PCM、
Manchester、1-Wire、Simple Parallel、UNI/O
Supported OS
Windows XP、Vista、Windows 7/8(32bit/64bit)