AFF A700s systems
Replacing the NVRAM adapter
To replace a failed NVRAM card, you must remove the NVRAM riser, Riser 1, from the controller module, remove the failed
card from the riser, install the new NVRAM card in the riser, and then reinstall the riser in the controller module. . Because the
system ID is derived from the NVRAM card, if replacing the module, disks belonging to the system are reassigned to the new
system ID.
Before you begin
• All disk shelves must be working properly.
• If your system is in an HA pair, the partner node must be able to take over the node associated with the NVRAM module
that is being replaced.
About this task
• This procedure uses the following terminology:
◦ The
impaired node
is the node on which you are performing maintenance.
◦ The
healthy node
is the HA partner of the impaired node.
• This procedure includes steps for automatically or manually reassigning disks to the controller module associated with the
new NVRAM module. You must reassign the disks when directed to in the procedure. Completing the disk reassignment
before giveback can cause issues.
• You must replace the failed component with a replacement FRU component you received from your provider.
• You cannot change any disks or disk shelves as part of this procedure.
Steps
1. Shutting down the impaired node on page 1
2. Removing the controller module on page 2
3. Removing the NVRAM card on page 4
4. Reinstalling the controller module and booting the system on page 6
5. Reassigning disks on page 6
6. Restoring Storage and Volume Encryption functionality on page 9
7. Completing the replacement process on page 9
Shutting down the impaired node
To shut down the impaired node, you must determine the status of the node and, if necessary, take over the node so that the
healthy node continues to serve data from the impaired node storage.
Before you begin
• If you have a cluster with more than two nodes, it must be in quorum. If the cluster is not in quorum or a healthy node shows
false for eligibility and health, you must correct the issue before shutting down the impaired node.
ONTAP 9 System Administration Reference
1
215-11303_2019-08_en-us August 2019 Copyright
©
2019 NetApp, Inc. All rights reserved.