EXA X-Series Signal Analyzer
N9010A
10 Hz to 3.6, 7.0, 13.6, 26.5, 32, or 44 GHz
Data Sheet
This data sheet is a summary of the specifications and conditions
for EXA and Express EXA signal analyzers. For the complete speci-
fications guide, visit: www.agilent.com/find/exa_specifications
![](https://csdnimg.cn/release/download_crawler_static/6747109/bg2.jpg)
2
Balance the Challenges
Whether you’re focused on time-
to-market, time-to-volume, or cost
of test, your choice of
economyclass signal analyzer
should help you save both time
and money. That’s the idea that
drives the Agilent EXA signal
analyzer—and it’s the fastest
way to maximize throughput
on the production line. From
measurement speed to code
compatibility, it makes every
millisecond count and helps
reduce your overall cost of test.
Definitions and Conditions ....................................................................................................... 3
Frequency and Time Specifications........................................................................................4
Amplitude Accuracy and Range Specifications .................................................................. 6
Dynamic Range Specifications ................................................................................................ 9
PowerSuite Measurement Specifications ..........................................................................15
General Specifications .............................................................................................................16
Inputs and Outputs ...................................................................................................................17
I/Q Analyzer ...............................................................................................................................19
Related Literature .....................................................................................................................21
Table of Contents
![](https://csdnimg.cn/release/download_crawler_static/6747109/bg3.jpg)
3
Get More Information
This EXA signal analyzer data
sheet is a summary of the
specifications and conditions
for N9010A EXA and N9010AEP
Express EXA signal analyzers,
which are available in the EXA
Signal Analyzer Specification
Guide (N9010-90025).
For ordering information, refer
to the EXA Signal Analyzer
Configuration Guide
(5989-6531EN).
Definitions and Conditions
Specifications describe the performance of parameters covered by the product
warranty and apply to the full temperature of 0 to 55 °C
1
, unless otherwise
noted.
95th percentile values indicate the breadth of the population (approx. 2 σ) of perfor-
mance tolerances expected to be met in 95 percent of the cases with a 95 percent
confidence, for any ambient temperature in the range of 20 to 30 °C. In addition to
the statistical observations of a sample of instruments, these values include the
effects of the uncertainties of external calibration references. These values are not
warranted. These values are updated occasionally if a significant change in the
statistically observed behavior of production instruments is observed.
Typical describes additional product performance information that is not covered by
the product warranty. It is performance beyond specifications that 80 percent of the
units exhibit with a 95 percent confidence level over the temperature range 20 to
30 °C. Typical performance does not include measurement uncertainty.
Nominal values indicate expected performance, or describe product performance
that is useful in the application of the product, but are not covered by the product
warranty.
The analyzer will meet its specifications when:
• It is within its calibration cycle
• Under auto couple control, except when Auto Sweep Time Rules = Accy
• Signal frequencies < 10 MHz, with DC coupling applied
• The analyzer has been stored at an ambient temperature within the allowed
operating range for at least two hours before being turned on; if it had previously
been stored at a temperature range inside the allowed storage range, but outside
the allowed operating range
• The analyzer has been turned on at least 30 minutes with Auto Align set to
normal, or, if Auto Align is set to off or partial, alignments must have been run
recently enough to prevent an Alert message; if the Alert condition is changed
from Time and Temperature to one of the disabled duration choices, the analyzer
may fail to meet specifications without informing the user
For the complete specifications guide, visit:
www.agilent.com/find/exa_specifications
1. For earlier instruments (Serial number prefix < MY/SG/US5052), the full temperature ranges
from 5 to 50 °C.
![](https://csdnimg.cn/release/download_crawler_static/6747109/bg4.jpg)
4
Frequency and Time Specifications
Frequency range DC coupled AC coupled
Option 503 10 Hz to 3.6 GHz 10 MHz to 3.6 GHz
Option 507 10 Hz to 7 GHz 10 MHz to 7 GHz
Option 513 10 Hz to 13.6 GHz 10 MHz to 13.6 GHz
Option 526 10 Hz to 26.5 GHz 10 MHz to 26.5 GHz
Option 532 10 Hz to 32 GHz NA
Option 544 10 Hz to 44 GHz NA
Band LO multiple (N)
0 1 10 Hz to 3.6 GHz
1 1 3.5 to 7.0 GHz
1 1 3.5 to 8.4 GHz
2 2 8.4 to 13.6 GHz
3 2 13.5 to 17.1 GHz
4 4 17 to 26.5 GHz
5 4 26.4 to 34.5 GHz
6 8 34.4 to 44 GHz
Frequency reference
Accuracy
± [(time since last adjustment x aging rate) + temperature stability + calibration
accuracy]
Aging rate
Option PFR Standard
± 1 x 10
–7
/ year ± 1 x 10
–6
/ year
± 1.5 x 10
–7
/ 2 years
Temperature stability
20 to 30 °C
Full temperature range
Option PFR Standard
± 1.5 x 10
–8
± 2 x 10
–6
± 5 x 10
–8
± 2 x 10
–6
Achievable initial calibration accuracy
Option PFR Standard
± 4 x 10
–8
± 1.4 x 10
–6
Example frequency reference accuracy
(with Option PFR)
= ± (1 x 10
–7
+ 5 x 10
–8
+ 4 x 10
–8
)
1 year after last adjustment
= ± 1.9 x 10
–7
Residual FM
Option PFR
Standard
≤ (0.25 Hz x N) p-p in 20 ms nominal
≤ (10 Hz x N) p-p in 20 ms nominal
See band table above for N (LO Multiple)
Frequency readout accuracy (start, stop, center, marker)
± (marker frequency x frequency reference accuracy + 0.25 % x span + 5 % x RBW
+ 2 Hz + 0.5 x horizontal resolution
1
)
Marker frequency counter
Accuracy
± (marker frequency x frequency reference accuracy + 0.100 Hz)
Delta counter accuracy
± (delta frequency x frequency reference accuracy + 0.141 Hz)
Counter resolution
0.001 Hz
Frequency span (FFT and swept mode)
Range 0 Hz (zero span), 10 Hz to maximum frequency of instrument
Resolution 2 Hz
Accuracy
Swept
FFT
± (0.25 % x span + horizontal resolution)
± (0.10 % x span + horizontal resolution)
1. Horizontal resolution is span/(sweep points – 1).
剩余20页未读,继续阅读
![avatar](https://profile-avatar.csdnimg.cn/07ce32e8e4e8429e905c0451057865ee_maojoujou.jpg!1)
maojoujou
- 粉丝: 4
- 资源: 5
上传资源 快速赚钱
我的内容管理 展开
我的资源 快来上传第一个资源
我的收益
登录查看自己的收益我的积分 登录查看自己的积分
我的C币 登录后查看C币余额
我的收藏
我的下载
下载帮助
![voice](https://csdnimg.cn/release/downloadcmsfe/public/img/voice.245cc511.png)
![center-task](https://csdnimg.cn/release/downloadcmsfe/public/img/center-task.c2eda91a.png)
最新资源
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
![feedback](https://img-home.csdnimg.cn/images/20220527035711.png)
![feedback](https://img-home.csdnimg.cn/images/20220527035711.png)
![feedback-tip](https://img-home.csdnimg.cn/images/20220527035111.png)
安全验证
文档复制为VIP权益,开通VIP直接复制
![dialog-icon](https://csdnimg.cn/release/downloadcmsfe/public/img/green-success.6a4acb44.png)
- 1
- 2
- 3
- 4
前往页