# V E R S I O N I N F O R M A T I O N
#
# Module: BASIC
# Date: Tue Feb 25 10:54:48 2020
#
# This file lists actual release notes for a RC series 30 module.
#
####################################################################################################
# (c) Copyright by BOSCH REXROTH AG, all rights reserved
####################################################################################################
****************************************************************************************************
* BASIC V01.99:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2300 (BASIC)
* FIX: ECC trap issue of DFLASH in RC4-5/30,
Issue:If ignition is ON and switch OFF while writing data into DFLASH in initialization phase
of the ECU.This was causing DFLASHH ECC Trap. if ECC trap occurred, it will continuously resets
the ECU and this error is not stored in error memory. Application is not executed in this situation.
****************************************************************************************************
* BASIC V01.98:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2269 (BASIC):
* CHG: New defines added for the ch2Rev_u8 parameter in the sent_cfgFDDecode() function to avoid the
confusion while reading the channel 2 nibbles in reversed/non-reversed manner. (see sent_api.h file)
#2272 (BASIC):
* CHG: In sent_cfgFDDecode() function the 16-bit counter length is not supported according to the
SAE J2716-2010-01 standard. So it is removed.
#2286 (BASIC):
* ADD: The SENT Fast Data FIFO Counter value(counter_u8) and the Message Status (msgStat_u8) nibble
was not updated previously. It is updated now.
****************************************************************************************************
* BASIC V01.97:
****************************************************************************************************
+-------+
| Tasks |
+-------+
#2287 (BASIC ):
* ADD: basic module is baselined with tag version with V01.97 for trap bug fixes during CAN wakeup and continuous reset.
****************************************************************************************************
* BASIC V01.96:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2259 (BASIC):
* CHG: function "ee_getStatus" modified for the condition "eeprom queue handling disable" during afterrun
****************************************************************************************************
* BASIC V01.95:
****************************************************************************************************
+-----------------+
| Change Requests |
+-----------------+
#2222 (BASIC):
* ADD: Internal Monitoring of Voltage difference between UBAT and VP_1 is enabled for RC4-5/30.
When VP_1 is ON, if the voltage difference is more than 6V with respect to UBAT then a
error will be set.
#2214 (BASIC):
*CHG: In RC4-5/30(old), MOCSOP feature was not enabled, Due this there was different
behavior of sys_setVp in RC4-5/30 hardware release(old) and hardware release RL2.
MOCSOP feature is enabled, so that sys_setVP behavior is same for all hardware release.
........
****************************************************************************************************
* BASIC V01.94A:
****************************************************************************************************
+-----------------+
| Change Requests |
+-----------------+
#2222 (BASIC):
* ADD: Internal Monitoring of Voltage difference between UBAT and VP_1 is enabled for RC4-5/30.
When VP_1 is ON, if the voltage difference is more than 6V with respect to UBAT then a
error will be set.
#2214 (BASIC):
*CHG: In RC4-5/30(old), MOCSOP feature was not enabled, Due this there was different
behavior of sys_setVp in RC4-5/30 hardware release(old) and hardware release RL2.
MOCSOP feature is enabled, so that sys_setVP behavior is same for all hardware release.
........
****************************************************************************************************
* BASIC V01.94:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2216 (BASIC):
* FIX: In V03.00, VP_1 was above 3.5V before calling sys_setvp(VP_1,ON).
Now VP_1 is less than 2V before calling sys_setVP(VP_1,ON)
****************************************************************************************************
* BASIC V01.93:
****************************************************************************************************
+-----------------+
| Change Requests |
+-----------------+
#2205 (BASIC):
* CHG: In CPM API the DIAG default parameter values are not set any more in case of a new SW name.
#2144 (BASIC DIAG):
* ADD: Earlier, No Monitoring for 3.3V internal Voltage.
3.3V internal voltage monitoring is enabled.
#2139 (BASIC):
* ADD: MOCSOP features is added to RC4-5/30 RL2
****************************************************************************************************
* BASIC V01.90:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2158 (BASIC):
* FIX: The state evaluation of VP's can be failed through an interrupt request.
+-------+
| Tasks |
+-------+
#1861 (BASIC):
* ADD: The LSAFOUT functionality is added for RC10-10
#1698 (BASIC DIAG TEMPLATE):
* ADD: Module SENT is added for RC10-10.
****************************************************************************************************
* BASIC V01.84A:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2158 (BASIC):
* FIX: The state evaluation of VP's can be failed through an interrupt request.
****************************************************************************************************
* BASIC V01.84:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#1848 (BASIC):
* CHG: SPI error handling changed to solve the monitoring error 0xE08/8
****************************************************************************************************
* BASIC V01.83:
****************************************************************************************************
+-----------------+
| Trouble Reports |
+-----------------+
#2103 (BASIC):
* FIX: If in safout mode POH more than one HS is configured and all configured HS's are
deactivated the behaviour after call of safout_resetError() is not correct...some
outputs are switched on even though that not all outputs are previously switched off.
#1737 (BASIC):
* FIX: Logging of temperature profile (Temperature Depending Operating Hours = TDOH)
old behavior:
Wrong temperature classification values can be calculated if ECU is restarted via software reset.
new behavior:
没有合适的资源?快使用搜索试试~ 我知道了~
Setup_V3.0.17.10_Targets.zip
共53个文件
txt:49个
xls:1个
dll:1个
需积分: 5 1 下载量 65 浏览量
2024-02-01
16:31:28
上传
评论
收藏 148.65MB ZIP 举报
温馨提示
Setup_V3.0.17.10_Targets
资源推荐
资源详情
资源评论
收起资源包目录
Setup_V3.0.17.10_Targets.zip (53个子文件)
Setup_V3.0.17.10_Targets
Setup_BODAS-design_Targets_3.0.17.10.exe 148.24MB
Versioninformation_RC36-20_30
VERSION_INFORMATION_RC30_RTM.txt 2KB
VERSION_INFORMATION_RC30_RCE.txt 1KB
VERSION_INFORMATION_RC30_ISOBUS.txt 4KB
VERSION_INFORMATION_RC36-20_30.txt 2KB
VERSION_INFORMATION_Important_changes.txt 65KB
VERSION_INFORMATION_RC30_OutExt.txt 2KB
VERSION_INFORMATION_RC30_J1939.txt 11KB
VERSION_INFORMATION_RC30_Baselines.txt 112KB
VERSION_INFORMATION_RC30_CCP.txt 1KB
VERSION_INFORMATION_RC30_Diag.txt 22KB
VERSION_INFORMATION_RC30_UDS.txt 4KB
VERSION_INFORMATION_RC30_Basic.txt 178KB
VERSION_INFORMATION_RC30_CANOPEN.txt 5KB
VERSION_INFORMATION_RC30_RTS.txt 13KB
VERSION_INFORMATION_RC30_MANUAL.txt 21KB
VERSION_INFORMATION_RC30_INext.txt 5KB
kwp2000_uds.dll 86KB
VERSION_INFORMATION_BODAS-design.xls 276KB
Versioninformation_RC28-14_30_Family
VERSION_INFORMATION_RC30_RCE.txt 979B
VERSION_INFORMATION_RC30_LIN.txt 532B
VERSION_INFORMATION_RC30_ISOBUS.txt 9KB
VERSION_INFORMATION_Important_changes.txt 120KB
VERSION_INFORMATION_RC30_OutExt.txt 2KB
VERSION_INFORMATION_RC30_J1939.txt 13KB
VERSION_INFORMATION_RC28-14_30.txt 5KB
VERSION_INFORMATION_RC30_Baselines.txt 141KB
VERSION_INFORMATION_RC30_CCP.txt 2KB
VERSION_INFORMATION_RC30_Diag.txt 30KB
VERSION_INFORMATION_RC30_UDS.txt 4KB
VERSION_INFORMATION_RC30_Basic.txt 242KB
VERSION_INFORMATION_RC30_CANOPEN.txt 4KB
VERSION_INFORMATION_RC30_RTS.txt 16KB
VERSION_INFORMATION_RC30_MANUAL.txt 44KB
VERSION_INFORMATION_RC30_INext.txt 4KB
Setup_V3.0.17.10_Targets.md5 5KB
Versioninformation_RC10-10_31
VERSION_INFORMATION_RC30_BASIC.txt 242KB
VERSION_INFORMATION_RC30_INEXT.txt 4KB
VERSION_INFORMATION_RC30_RCE.txt 979B
VERSION_INFORMATION_RC30_LIN.txt 532B
VERSION_INFORMATION_RC30_ISOBUS.txt 9KB
VERSION_INFORMATION_Important_changes.txt 37KB
VERSION_INFORMATION_RC30_J1939.txt 13KB
VERSION_INFORMATION_RC30_Baselines.txt 55KB
VERSION_INFORMATION_RC30_CCP.txt 2KB
VERSION_INFORMATION_RC10-10_31.txt 3KB
VERSION_INFORMATION_RC30_UDS.txt 4KB
VERSION_INFORMATION_RC30_CANOPEN.txt 4KB
VERSION_INFORMATION_RC30_RTS.txt 16KB
VERSION_INFORMATION_RC30_OUTEXT.txt 2KB
VERSION_INFORMATION_RC30_ACOM.txt 533B
VERSION_INFORMATION_RC30_DIAG.txt 30KB
VERSION_INFORMATION_RC30_MANUAL.txt 44KB
共 53 条
- 1
资源评论
longrenwenzi
- 粉丝: 0
- 资源: 8
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功