PUBLISHED SFF-TA-1016 Rev 1.2
Internal Unshielded High Speed Connector System Page 1
Copyright © 2024 SNIA. All rights reserved.
SFF-TA-1016
Specification for
Internal Unshielded High Speed Connector System
Rev 1.2 March 07, 2024.
SECRETARIAT: SFF TA TWG
This specification is made available for public review at https://www.snia.org/sff/specifications
. Comments may be
submitted at https://www.snia.org/feedback. Comments received will be considered for inclusion in future revisions
of this specification.
The description of the connector in this specification does not assure that the specific component is available from
connector suppliers. If such a connector is supplied, it should comply with this specification to achieve
interoperability between suppliers.
ABSTRACT: This specification defines the mechanical specifications and general performance requirements for an
Internal Unshielded High Speed Connector System that is designed for use in high speed serial interconnect
applications. One such use may be as a 4, 8, or 16 lane (or more) receptacle and the mating cable plug for multiple
generations of internal high speed applications.
POINTS OF CONTACT:
Paul Coddington Chairman SFF TA TWG
Amphenol High Speed Interconnects Email: SFF-Chair@snia.org
20 Valley Street
Endicott, NY 13760
Ph: 607-754-4444
Email: paul.coddington@amphenol-highspeed.com
PUBLISHED SFF-TA-1016 Rev 1.2
Internal Unshielded High Speed Connector System Page 2
Copyright © 2024 SNIA. All rights reserved.
Intellectual Property
The user's attention is called to the possibility that implementation of this specification may require the use of an
invention covered by patent rights. By distribution of this specification, no position is taken with respect to the
validity of a claim or claims or of any patent rights in connection therewith.
This specification is considered SNIA Architecture and is covered by the SNIA IP Policy and as a result goes through
a request for disclosure when it is published. Additional information can be found at the following locations:
• Results of IP Disclosures: https://www.snia.org/sffdisclosures
• SNIA IP Policy: https://www.snia.org/ippolicy
Copyright
The SNIA hereby grants permission for individuals to use this document for personal use only, and for corporations
and other business entities to use this document for internal use only (including internal copying, distribution, and
display) provided that:
1.
Any text, diagram, chart, table or definition reproduced shall be reproduced in its entirety with no
alteration, and,
2.
Any document, printed or electronic, in which material from this document (or any portion hereof) is
reproduced shall acknowledge the SNIA copyright on that material, and shall credit the SNIA for granting
permission for its reuse.
Other than as explicitly provided above, there may be no commercial use of this document, or sale of any part, or
this entire document, or distribution of this document to third parties. All rights not explicitly granted are expressly
reserved to SNIA.
Permission to use this document for purposes other than those enumerated (Exception) above may be requested
by e-mailing copyright_request@snia.org
. Please include the identity of the requesting individual and/or company
and a brief description of the purpose, nature, and scope of the requested use. Permission for the Exception shall
not be unreasonably withheld. It can be assumed permission is granted if the Exception request is not acknowledged
within ten (10) business days of SNIA's receipt. Any denial of permission for the Exception shall include an
explanation of such refusal.
Disclaimer
The information contained in this publication is subject to change without notice. The SNIA makes no warranty of
any kind with regard to this specification, including, but not limited to, the implied warranties of merchantability
and fitness for a particular purpose. The SNIA shall not be liable for errors contained herein or for incidental or
consequential damages in connection with the furnishing, performance, or use of this specification.
Suggestions for revisions should be directed to https://www.snia.org/feedback
.
PUBLISHED SFF-TA-1016 Rev 1.2
Internal Unshielded High Speed Connector System Page 3
Copyright © 2024 SNIA. All rights reserved.
Foreword
The development work on this specification was done by the SNIA SFF TA TWG, an industry group. Since its
formation as the SFF Committee in August 1990, the membership has included a mix of companies that are leaders
across the industry.
For those who wish to participate in the activities of the SFF TA TWG, the signup for membership can be found at
https://www.snia.org/sff/join
.
Revision History
Rev 1.0
June 02, 2021
:
- First Publication
Rev 1.1
March 01, 2023
:
- Updated the tolerances of dimensions A16, C16, E16, and G16 from ±0.20 to +0.20/-0.05.
- The values for dimensions B08 and B09 in Table 5-6 were reversed to match the applicable
drawing dimensions shown in Figure 5-8.
- Updated Figure 6-1 and Table 6-1 to add dimension J23.
- Updated Figure 6-2, Figure 6-3, and Table 6-2 to add dimension L23.
- Updated Figure 6-4 and Table 6-3 to add dimension N21.
- Updated Figure 6-5 and Table 6-4 to add dimension Q21.
- Updated copyright date to 2023.
Rev 1.2
March 07, 2024
:
- Minor editorial edits
- Added the no anti-skew flange versions of the 38P, 124P, and 148P size plugs in the same
manner as the 74P size plug that was already included. Added new Figure 6-2 Straight Plug
with No Side Flanges for 38 Contacts and modified Table 6-1 accordingly, including adding
Notes 1, 2, & 3. Added new Figure 6-6 Straight Plug with No Side Flanges for 124 Contacts
and modified Table 6-3 accordingly, including adding Notes 1, 2, & 3. Added new Figure 6-8
Straight Plug with No Side Flanges for 148 Contacts and modified Table 6-4 accordingly,
including adding Notes 1, 2, & 3.
- Updated list of Industry Documents in section 2.1.
- Added EDSFF to Acronyms and Abbreviations in section 3.2.
- Added new section 4.1.5 Connector Configuration 5 – Hybrid EDSFF Solution Connectors and
inserted a new Figure 4-6, renumbering the remaining section 4 figures accordingly.
- Inserted a new Section 7 Hybrid EDSFF Solution Mechanical Specification, renumbering the
remaining section numbers accordingly. Added new Figure 7-1, new Table 7-1, new Figure 7-2,
new Table 7-2, new Figure 7-3, new Table 7-3, new Figure 7-4, new Table 7-4, new
Figure
7-5, new Table 7-5, new Figure 7-6, and new Table 7-6
- In Appendix A, added new section A.2.5 including new Figure A-5 and new Table A-5.
- Added a new paragraph to Section 7.1 mentioning how the signals and sidebands may be
connected within the hybrid EDSFF solution plugs.
- Updated Figure 7-1 to align Datum A with the paddle card thickness dimension, K02, since the
datum is intended to be the centerline of the paddle card thickness, not the bottom surface.
- Updated Figure 7-3 to add the missing centerlines in the top view, added dimension BB35,
updated dimension BB13, and added the missing True Position tolerance to the BB10
dimension. Also, updated Table 7-3 accordingly.
- Updated Figure 7-4 to correct a typo regarding dimensions BD19, BD20, and BD21 (were
incorrectly labeled in this figure as BE19, BE20, and BE21).
- Updated Figure 7-6 to add the missing centerlines in the top view, added dimension BA35,
updated dimension BA13, and moved the True Position tolerance from the BA14 dimension to
the BA10 dimension. Also, updated Table 7-6 accordingly.
- Fixed several website addresses & associated hyperlinks and made a few editorial changes per
the Approval Ballot Comment Resolution.
PUBLISHED SFF-TA-1016 Rev 1.2
Internal Unshielded High Speed Connector System Page 4
Copyright © 2024 SNIA. All rights reserved.
Contents
1.
Scope 8
2. References and Conventions 8
2.1 Industry Documents 8
2.2 Sources 8
2.3 Conventions 9
3. Keywords, Acronyms, and Definitions 10
3.1 Keywords 10
3.2 Acronyms and Abbreviations 10
3.3 Definitions 11
4. General Description 13
4.1 Configuration Overview/Descriptions 13
4.1.1 Connector Configuration 1 – 38 Contact Connectors 13
4.1.2 Connector Configuration 2 – 74 Contact Connectors 14
4.1.3 Connector Configuration 3 – 124 Contact Connectors 14
4.1.4 Connector Configuration 4 – 148 Contact Connectors 14
4.1.5 Connector Configuration 5 – Hybrid EDSFF Solution Connectors 15
4.2 Contact Numbering 16
5. Connector Mechanical Specification 18
5.1 Overview 18
5.1.1 Datums 18
5.2 Mechanical Description: Right Angle Connectors 21
5.2.1 Right Angle Connector with 38 Contacts 21
5.2.2 Right Angle Connector with 74 Contacts 23
5.2.3 Right Angle Connector with 124 Contacts 25
5.2.4 Right Angle Connector with 148 Contacts 27
5.3 Mechanical Description: Vertical Connectors 29
5.3.1 Vertical Connector with 38 Contacts 29
5.3.2 Vertical Connector with 74 Contacts 31
5.3.3 Vertical Connector with 124 Contacts 33
5.3.4 Vertical Connector with 148 Contacts 35
5.4 Outer Locus of the Right Angle Connector and Vertical Connector Mating Contacts 37
5.5 Outer Locus of the SMT Leads 38
6. Module Mechanical Specification 41
6.1 Overview 41
6.2 Mechanical Description: Plug Modules 41
6.2.1 Plug Connector with 38 Contacts 41
6.2.2 Plug Connector with 74 Contacts 44
6.2.3 Plug Connector with 124 Contacts 46
6.2.4 Plug Connector with 148 Contacts 48
6.2.5 Right Angle Plug Connector with 38/74/124/148 Contacts 50
6.3 Card Edge Description (Mechanical Interface) 51
6.3.1 Plug Paddle Card with 38 Contacts 51
6.3.2 Plug Paddle Card with 74 Contacts 52
6.3.3 Plug Paddle Card with 124 Contacts 53
6.3.4 Plug Paddle Card with 148 Contacts 54
7. Hybrid EDSFF Solution Mechanical Specification 55
7.1 Hybrid EDSFF Solution Overview 55
7.2 Mechanical Description: EDSFF E1 Hybrid Connectors 55
7.2.1 Hybrid Plug with 38 Contacts and E1 1C Connector 55
7.2.2 Hybrid Plug with 38 Contacts and E1 2C Connector 57
7.2.3 Hybrid E1 Vertical Receptacle Connector with 38 Contacts 59
PUBLISHED SFF-TA-1016 Rev 1.2
Internal Unshielded High Speed Connector System Page 5
Copyright © 2024 SNIA. All rights reserved.
7.3
Mechanical Description: EDSFF E3 Hybrid Connectors 61
7.3.1 Hybrid Plug with 38 Contacts and E3 1C Connector 61
7.3.2 Hybrid Plug with 38 Contacts and E3 2C Connector 63
7.3.3 Hybrid E3 Vertical Receptacle Connector with 38 Contacts 65
8. Test Requirements and Methodologies (TS-1000, etc.) 67
8.1 Performance Tables 67
9. Electrical Characteristics 71
9.1 Signal Integrity Requirements 71
Appendix A: System Mechanical Specification (Informative) 72
A.1 Overview 72
A.2 PCB Layout 72
A.2.1 Recommended PCB layout for Right Angle 38P/74P Connector Footprints 72
A.2.2 Recommended PCB layout for Right Angle 124P/148P Connector Footprints 74
A.2.3 Recommended PCB layout for Vertical 38P/74P Connector Footprints 75
A.2.4 Recommended PCB layout for Vertical 124P/148P Connector Footprints 76
A.2.5 Recommended PCB layout for Hybrid EDSFF E1/E3 Vertical 38P Connector Footprints 77
Appendix B: SMT Connector Solder Lead Geometry (Informative) 78
Appendix C: Reference Pinout Diagrams (Informative) 79
C.1 Overview of Contact Geometry Patterns 79
C.2 Recommended Cable Assembly Wire Diagrams 85
Appendix D: Gatherability (Informative) 89