H3C S5560-EI Switch Series Installation Quick Start-6PW104
H3C S5560-EI 系列以太网交换机 快速安装指南-6PW104
BOM: 3104A0E1
Before installation, wear an ESD wrist strap, and make sure the wrist strap makes good skin contact and is
reliably grounded.在以下安装交换机的过程中,操作者需佩戴防静电腕带,请确保防静电腕带已经正确接地并
与皮肤良好接触。
The installation tools are not provided with the switch. Prepare them yourself. 交换机不随机提供安装工具,请
用户根据实际安装需求自己准备安装工具。
Tool list 工具参考
Grounding cable
接地线
Grounding screw
接地螺钉
M6 screw (user supplied)
M6 螺钉(请用户自备)
Front mounting brackets
and M4 screw
前挂耳和M4螺钉
Cage nut (user supplied)
浮动螺母(请用户自备)
Chassis rail and slide rail
(optional)
滑道和导轨(选配)
P
h
illip
s
s
c
r
e
w
d
r
iv
e
r
十
字
螺
丝
刀
M
a
r
k
e
r
记
号
笔
F
la
t-b
la
d
e
s
c
r
e
w
d
r
iv
e
r
一
字
螺
丝
刀
Mounting the switch in a rack 安装交换机到机柜
Installation accessories 安装附件介绍
Using front mounting brackets 前挂耳安装
The installation position for the front mounting brackets varies by switch model.仅使用一对前挂耳安装设备到机
柜时,不同机型可选择的挂耳安装位置不同。
Four screws are required to attach a front mounting bracket to the switch.单个挂耳必须使用四个螺钉进行固定。
For the S5560-54QS-EI switch, you can install the front mounting brackets only at the power module side position.
对于S5560-54QS-EI,只能将前挂耳安装在设备电源侧安装位。
1
Rubber feet
脚垫
Rear mounting bracket
and load-bearing screw
后挂耳和承重螺钉
Needle-nose pliers
尖嘴钳
ESD wrist strap
防静电腕带
Blow dryer
热吹风
Diagonal pliers
斜口钳
1
Attach the front mounting brackets to the switch 安装前挂耳到交换机
Install cage nuts 安装浮动螺母 Mount the switch in a rack 安装交换机到机柜
Installation at the port side 端口侧安装 Installation at the power side 电源侧安装
!
!
Using front and rear mounting brackets 前挂耳和后挂耳配合安装
2
This section is applicable to switch models that are provided with front and rear mounting brackets.
本节内容适用于标配前后挂耳的机型。
You can install the front mounting brackets at the port side or power module side of the switch as needed. (This section
describes installation at the port side, which is similar to installation at the power module side.)用户可以根据安
装场景的需要,将前挂耳安装在设备端口侧或电源侧(下面仅以将前挂耳安装在设备端口侧为例介绍安装过程,将
前挂耳安装在电源侧时安装方法类似)。
Installation methods for the rear mounting brackets vary by the rack depth.
For the S5560-30C-PWR-EI and S5560-54C-PWR-EI switches, if the rack depth is in the range of 429 to 595 mm
(16.89 to 23.43 in), orient the bracket with the wide flange inside the rack. If the rack depth is in the rang of 274 to 440
mm (10.79 to 17.32 in), orient the bracket with the wide flange outside the rack and make sure the distance from the rear
rack posts to the inner surface of the cabinet door is larger than 153 mm (6.02 in).
For the S5560-54QS-EI switch, if the rack depth is in the range of 332 to 496 mm (13.07 to 19.53 in), orient the
bracket with the wide flange inside the rack. If the rack depth is in the range of 174 to 341 mm (6.85 to 13.43 in), orient
the bracket with the wide flange outside the rack and make sure the distance from the rear rack posts to the inner surface of
the cabinet door is larger than 153 mm (6.02 in).
后挂耳固定到机柜方孔条时,支持正向安装和反向安装两种安装方式:
方式一:正向安装,对于S5560-30C-PWR-EI和S5560-54C-PWR-EI,适用于前后立柱方孔条间距在
429mm~595mm范围内的机柜;对于S5560-54QS-EI,适用于前后立柱方孔条间距在332mm~496mm范围
内的机柜。
方式二:反向安装,对于S5560-30C-PWR-EI和S5560-54C-PWR-EI,适用于前后立柱方孔条间距在
274mm~440mm范围内的机柜;对于S5560-54QS-EI,适用于前后立柱方孔条间距在174mm~341mm范围
内的机柜。且固定后挂耳的机柜方孔条到机柜门内侧的垂直距离应大于153mm,否则安装完成后,后挂耳会
妨碍机柜门的正常关闭。
2
!
1U