Keysight InfiniiVision
6000 X-Series Oscilloscopes
Programmer's
Guide
2 Keysight InfiniiVision 6000 X-Series Oscilloscopes Programmer's Guide
Notices
© Keysight Technologies, Inc. 2005-2021
No part of this manual may be reproduced in
any form or by any means (including
electronic storage and retrieval or
translation into a foreign language) without
prior agreement and written consent from
Keysight Technologies, Inc. as governed by
United States and international copyright
laws.
Revision
Version 07.50.0000
Edition
November 12, 2021
Available in electronic format only
Published by:
Keysight Technologies, Inc.
1900 Garden of the Gods Road
Colorado Springs, CO 80907 USA
Warranty
The material contained in this document is
provided "as is," and is subject to being
changed, without notice, in future editions.
Further, to the maximum extent permitted
by applicable law, Keysight disclaims all
warranties, either express or implied, with
regard to this manual and any information
contained herein, including but not limited
to the implied warranties of
merchantability and fitness for a particular
purpose. Keysight shall not be liable for
errors or for incidental or consequential
damages in connection with the furnishing,
use, or performance of this document or of
any information contained herein. Should
Keysight and the user have a separate
written agreement with warranty terms
covering the material in this document that
conflict with these terms, the warranty
terms in the separate agreement shall
control.
Technology License
The hardware and/or software described in
this document are furnished under a license
and may be used or copied only in
accordance with the terms of such license.
U.S. Government Rights
The Software is "commercial computer
software," as defined by Federal Acquisition
Regulation ("FAR") 2.101. Pursuant to FAR
12.212 and 27.405-3 and Department of
Defense FAR Supplement ("DFARS")
227.7202, the U.S. government acquires
commercial computer software under the
same terms by which the software is
customarily provided to the public.
Accordingly, Keysight provides the Software
to U.S. government customers under its
standard commercial license, which is
embodied in its End User License Agreement
(EULA), a copy of which can be found at
www.keysight.com/find/sweula. The
license set forth in the EULA represents the
exclusive authority by which the U.S.
government may use, modify, distribute, or
disclose the Software. The EULA and the
license set forth therein, does not require or
permit, among other things, that Keysight:
(1) Furnish technical information related to
commercial computer software or
commercial computer software
documentation that is not customarily
provided to the public; or (2) Relinquish to,
or otherwise provide, the government rights
in excess of these rights customarily
provided to the public to use, modify,
reproduce, release, perform, display, or
disclose commercial computer software or
commercial computer software
documentation. No additional government
requirements beyond those set forth in the
EULA shall apply, except to the extent that
those terms, rights, or licenses are explicitly
required from all providers of commercial
computer software pursuant to the FAR and
the DFARS and are set forth specifically in
writing elsewhere in the EULA. Keysight
shall be under no obligation to update,
revise or otherwise modify the Software.
With respect to any technical data as
defined by FAR 2.101, pursuant to FAR
12.211 and 27.404.2 and DFARS 227.7102,
the U.S. government acquires no greater
than Limited Rights as defined in FAR 27.401
or DFAR 227.7103-5 (c), as applicable in any
technical data.
Safety Notices
CAUTION
A CAUTION notice denotes a hazard.
It calls attention to an operating
procedure, practice, or the like that,
if not correctly performed or
adhered to, could result in damage
to the product or loss of important
data. Do not proceed beyond a
CAUTION notice until the indicated
conditions are fully understood and
met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly
performed or adhered to, could
result in personal injury or death.
Do not proceed beyond a WARNING
notice until the indicated
conditions are fully understood and
met.
Keysight InfiniiVision 6000 X-Series Oscilloscopes Programmer's Guide 3
In This Book
This book is your guide to programming the 6000 X-Series oscilloscopes:
The first few chapters describe how to set up and get started:
• Chapter 1, “What's New,” starting on page 41, describes programming
command changes in the latest version of oscilloscope software.
• Chapter 2, “Setting Up,” starting on page 63, describes the steps you must take
before you can program the oscilloscope.
• Chapter 3, “Getting Started,” starting on page 71, gives a general overview of
oscilloscope program structure and shows how to program the oscilloscope
using a few simple examples.
• Chapter 4, “Sequential (Blocking) vs. Overlapped Commands,” starting on page
85, describes these command types and how they affect the oscilloscope and
synchronization.
• Chapter 5, “Commands Quick Reference,” starting on page 87, is a brief listing
of the 6000 X-Series oscilloscope commands and syntax.
The next chapters provide reference information on common commands, root level
commands, other subsystem commands, and error messages:
• Chapter 6, “Common (*) Commands,” starting on page 227, describes
commands defined by the IEEE 488.2 standard that are common to all
instruments.
• Chapter 7, “Root (:) Commands,” starting on page 255, describes commands
that reside at the root level of the command tree and control many of the basic
functions of the oscilloscope.
• Chapter 8, “:ACQuire Commands,” starting on page 299, describes commands
for setting the parameters used when acquiring and storing data.
• Chapter 9, “:BUS<n> Commands,” starting on page 319, describes commands
that control all oscilloscope functions associated with the digital channels bus
display.
• Chapter 10, “:CALibrate Commands,” starting on page 329, describes utility
commands for determining the state of the calibration factor protection button.
Table 1 6000 X-Series Model Numbers, Bandwidths, Sample Rates
Model Analog
Channels
Digital
Channels
Bandwidth Options Sample Rate (interleaved,
non-interleaved)
DSO-X 6002A 2
• (none) = 1 GHz
• BW250 = 2.5 GHz
• BW400 = 4 GHz
• BW600 = 6 GHz
20 GSa/s, 10 GSa/s
DSO-X 6004A 4
MSO-X 6002A 2 16
MSO-X 6004A 4 16
4 Keysight InfiniiVision 6000 X-Series Oscilloscopes Programmer's Guide
• Chapter 11, “:CGRade Commands,” starting on page 339, describes
commands that control the color grade waveform analysis feature.
• Chapter 12, “:CHANnel<n> Commands,” starting on page 347, describes
commands that control all oscilloscope functions associated with individual
analog channels or groups of channels.
• Chapter 13, “:CLOCk Commands,” starting on page 381, describes clock
recovery commands.
• Chapter 14, “:COMPliance Commands,” starting on page 387, describes
commands that control the license-enabled USB 2.0 signal quality analysis
feature.
• Chapter 15, “:COUNter Commands,” starting on page 399, describes
commands that control the counter analysis feature.
• Chapter 16, “:DEMO Commands,” starting on page 411, describes commands
that control the education kit demonstration signals that can be output on the
oscilloscope's Demo 1 and Demo 2 terminals.
• Chapter 17, “:DIGital<d> Commands,” starting on page 419, describes
commands that control all oscilloscope functions associated with individual
digital channels.
• Chapter 18, “:DISPlay Commands,” starting on page 427, describes commands
that control how waveforms, graticule, and text are displayed and written on
the screen.
• Chapter 19, “:DVM Commands,” starting on page 453, describes commands
that control the digital voltmeter analysis feature.
• Chapter 20, “:EXTernal Trigger Commands,” starting on page 459, describes
commands that control the input characteristics of the external trigger input.
• Chapter 21, “:FRANalysis Commands,” starting on page 465, describes
commands that control oscilloscope functions associated with the Frequency
Response Analysis (FRA) feature, which is available is with the license-enabled
built-in waveform generator).
• Chapter 22, “:FUNCtion<m> Commands,” starting on page 481, describes
commands that control math waveforms.
• Chapter 23, “:HARDcopy/:HCOPY Commands,” starting on page 537,
describes commands that set and query the selection of hardcopy device and
formatting options.
• Chapter 24, “:HISTogram Commands,” starting on page 557, describes
commands that control the histogram analysis feature.
• Chapter 25, “:JITTer Commands,” starting on page 573, describes commands
that control the license-enabled jitter analysis feature.
• Chapter 26, “:LISTer Commands,” starting on page 593, describes commands
that turn on/off the Lister display for decoded serial data and get the Lister
data.
• Chapter 27, “:LTESt Commands,” starting on page 597, describes commands
that control the Measurement Limit Test feature.
Keysight InfiniiVision 6000 X-Series Oscilloscopes Programmer's Guide 5
• Chapter 28, “:MARKer Commands,” starting on page 611, describes commands
that set and query the settings of X-axis markers (X1 and X2 cursors) and the
Y-axis markers (Y1 and Y2 cursors).
• Chapter 29, “:MEASure Commands,” starting on page 633, describes
commands that select automatic measurements (and control markers).
• Chapter 30, “:MEASure Power Commands,” starting on page 755, describes
measurement commands that are available when the power measurements and
analysis application is licensed and enabled.
• Chapter 31, “:MTESt Commands,” starting on page 779, describes commands
that control the license-enabled mask test feature.
• Chapter 32, “:POD Commands,” starting on page 813, describes commands
that control all oscilloscope functions associated with groups of digital
channels.
• Chapter 33, “:POWer Commands,” starting on page 819, describes commands
that control the license-enabled power measurement application.
• Chapter 34, “:RECall Commands,” starting on page 923, describes commands
that recall previously saved oscilloscope setups, reference waveforms, or
masks.
• Chapter 35, “:RTEYe Commands,” starting on page 935, describes commands
for controlling the real-time eye analysis feature.
• Chapter 36, “:SAVE Commands,” starting on page 941, describes commands
that save oscilloscope setups, screen images, and data.
• Chapter 37, “:SBUS<n> Commands,” starting on page 975, describes
commands that control oscilloscope functions associated with the serial
decode bus and serial triggering.
• Chapter 38, “:SEARch Commands,” starting on page 1271, describes
commands that control oscilloscope functions associated with searching for
waveform events.
• Chapter 39, “:SYSTem Commands,” starting on page 1381, describes
commands that control basic system functions of the oscilloscope.
• Chapter 40, “:TIMebase Commands,” starting on page 1407, describes
commands that control all horizontal sweep functions.
• Chapter 41, “:TRIGger Commands,” starting on page 1421, describes
commands that control the trigger modes and parameters for each trigger
type.
• Chapter 42, “:WAVeform Commands,” starting on page 1509, describes
commands that provide access to waveform data.
• Chapter 43, “:WGEN<w> Commands,” starting on page 1547, describes
commands that control waveform generator (WAVEGEN license) functions and
parameters.
• Chapter 44, “:WMEMory<r> Commands,” starting on page 1597, describes
commands that control reference waveforms.