没有合适的资源?快使用搜索试试~ 我知道了~
Adaptec_raid卡使用手册.pdf
需积分: 50 10 下载量 164 浏览量
2021-01-20
14:29:52
上传
评论 1
收藏 4.37MB PDF 举报
温馨提示
包含Adaptec系列Raid卡安装、Raid配置、安装系统指导、raid卡故障排错等,型号AdaptecRAID6405、AdaptecRAID6445、AdaptecRAID6805/6805Q、6405E、6805E/6805ER5、6405T、6805T/6805TQ、7805/7805Q、71605/71605Q、71605E、71685、72405。
资源推荐
资源详情
资源评论
.
Serial Attached SCSI RAID
Controllers Installation
and User's Guide
CDP-00277-02-A Rev. A
Issue: December 4, 2012
Copyright © PMC-Sierra, Inc. All rights reserved.
The information in this document is proprietary and condential to
PMC-Sierra, Inc. In any event, no part of this document may be reproduced
or redistributed in any form without the express written consent of
PMC-Sierra, Inc.
CDP-00277-02-A Rev. A, IssueNumber
None of the information contained in this document constitutes an express
or implied warranty by PMC-Sierra, Inc. as to the sufciency, tness or
suitability for a particular purpose of any such information or the tness, or
suitability for a particular purpose, merchantability, performance, compatibility
with other parts or systems, of any of the products of PMC-Sierra, Inc., or any
portion thereof, referred to in this document. PMC-Sierra, Inc. expressly
disclaims all representations and warranties of any kind regarding the contents
or use of the information, including, but not limited to, express and implied
warranties of accuracy, completeness, merchantability, tness for a particular
use, or non-infringement.
In no event will PMC-Sierra, Inc. be liable for any direct, indirect, special,
incidental or consequential damages, including, but not limited to, lost prots,
lost business or lost data resulting from any use of or reliance upon the
information, whether or not PMC-Sierra, Inc. has been advised of the
possibility of such damage.
For a complete list of PMC-Sierra’s trademarks and registered trademarks,
visit: http://www.pmc-sierra.com/legal/.
Other product and company names mentioned herein may be the trademarks
of their respective owners.
2Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide
Revision History
Details of ChangeIssue DateIssue
Adaptec Firmware/BIOS/Drivers/Utilities Version 1.1December 4,
2012
1.1
3Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide
Contents
Adaptec by PMC Product Support..............................................................................................................................8
Limited 3-Year Hardware Warranty..........................................................................................................................10
Regulatory Compliance Statements..........................................................................................................................11
1 About This Guide..................................................................................................................................................14
What You Need to Know Before You Begin..................................................................................................14
Terminology Used in this Guide...................................................................................................................14
How to Find More Information....................................................................................................................14
2 Kit Contents and System Requirements................................................................................................................16
Kit Contents..................................................................................................................................................16
System Requirements ..................................................................................................................................16
3 About Your RAID Controller..................................................................................................................................17
Standard RAID Controller Features..............................................................................................................17
Array-level Features.........................................................................................................................17
Advanced Data Protection Suite......................................................................................................17
Adding a Flash Backup Module....................................................................................................................18
Upgrading the Controller Firmware.............................................................................................................18
About the Adaptec RAID 6405.....................................................................................................................19
About the Adaptec RAID 6445.....................................................................................................................20
About the Adaptec RAID 6805/6805Q.........................................................................................................21
About the Adaptec RAID 6405E...................................................................................................................22
About the Adaptec RAID 6805E/6805E R5...................................................................................................23
About the Adaptec RAID 6405T...................................................................................................................24
About the Adaptec RAID 6805T/6805TQ......................................................................................................25
About the Adaptec RAID 7805/7805Q.........................................................................................................26
About the Adaptec RAID 71605/71605Q.....................................................................................................27
About the Adaptec RAID 71605E.................................................................................................................28
About the Adaptec RAID 71685...................................................................................................................29
About the Adaptec RAID 72405...................................................................................................................30
4 Getting Started......................................................................................................................................................31
Choosing a RAID Level..................................................................................................................................31
Selecting Disk Drives and Cables .................................................................................................................31
Disk Drives.......................................................................................................................................31
Cables..............................................................................................................................................31
Replacing the Full-Height Bracket with a Low-Prole Bracket.....................................................................33
Installation Options......................................................................................................................................34
Basic Installation Steps.................................................................................................................................34
Installing with an Operating System................................................................................................35
Installing on an Existing Operating System......................................................................................35
5 Installing the Controller and Disk Drives...............................................................................................................36
Before You Begin..........................................................................................................................................36
Installing the Controller................................................................................................................................36
Installing a RAID Controller without Zero Maintenance Cache Protection......................................36
Installing a RAID Controller with Zero Maintenance Cache Protection ..........................................37
Connecting Disk Drives to Your Controllers..................................................................................................41
Connecting Drives Directly to the Controller...................................................................................41
Connecting Drives to a System Backplane.......................................................................................41
Connecting Solid State Drives (SSDs) ..............................................................................................41
Connecting External Devices .......................................................................................................................42
Next Steps....................................................................................................................................................43
6 Creating a Bootable Array ....................................................................................................................................44
4Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide
Setting the Boot Controller..........................................................................................................................44
Creating an Array..........................................................................................................................................44
Creating an Array with the ARC Utility.............................................................................................44
Creating an Array with maxView Storage Manager.........................................................................45
Making Your Array Bootable........................................................................................................................47
7 Installing the Driver and an Operating System .....................................................................................................48
Before You Begin..........................................................................................................................................48
Creating a Driver Disk...................................................................................................................................48
Creating a Driver Disk for Debian Linux or Ubuntu Linux ...............................................................49
Creating a Driver Disk for VMware ESX 4.1 .....................................................................................49
Installing with Windows ..............................................................................................................................50
Installing with Red Hat Linux 5 or Cent OS 5 ...............................................................................................50
Installing with Red Hat Linux 6, Cent OS 6, or Fedora Linux ........................................................................50
Red Hat Linux 6, Cent OS 6 with Dynamic Kernel Module Support ................................................50
Red Hat Linux 6, Cent OS 6, Fedora Linux without Dynamic Kernel Module Support ....................51
Installing with SuSE Linux Enterprise Server ...............................................................................................52
Installing with Debian Linux.........................................................................................................................52
Installing with Ubuntu Linux........................................................................................................................53
Installing with Solaris...................................................................................................................................54
Installing with FreeBSD ................................................................................................................................55
Installing with VMware ESX 4.1 ...................................................................................................................55
Installing with VMware ESXi 5.x ..................................................................................................................56
8 Installing the Driver on an Existing Operating System .........................................................................................59
Before You Begin..........................................................................................................................................59
Creating a Driver Disk...................................................................................................................................59
Installing on Windows .................................................................................................................................59
Installing on Red Hat, Cent OS, SuSE, or Fedora Linux.................................................................................60
Installing on Debian Linux............................................................................................................................60
Installing on Ubuntu Linux...........................................................................................................................60
Installing on Solaris .....................................................................................................................................61
Installing on FreeBSD ...................................................................................................................................61
Installing on VMware...................................................................................................................................62
9 Managing Your Storage Space..............................................................................................................................64
About maxView Storage Manager...............................................................................................................64
Installing maxView Storage Manager..............................................................................................64
About the Adaptec RAID Controller Conguration Utility............................................................................64
About the Adaptec RAID Conguration Utility.............................................................................................64
About the Adaptec Flash Utility...................................................................................................................65
Which Utility Should I Use?..........................................................................................................................65
10 Solving Problems ................................................................................................................................................66
Troubleshooting Checklist............................................................................................................................66
Monitoring Disk Drives Status......................................................................................................................66
Silencing the Alarm .....................................................................................................................................66
Recovering from a Disk Drive Failure ...........................................................................................................66
Failed Disk Drive Protected by a Hot Spare .....................................................................................67
Failed Disk Drive Not Protected by a Hot Spare ..............................................................................67
Failure in Multiple Arrays Simultaneously ......................................................................................67
Disk Drive Failure in a RAID 0 Array ................................................................................................67
Multiple Failures in the Same Array ................................................................................................67
Failed SSD in maxCache Container..................................................................................................68
Resetting the Controller ..............................................................................................................................68
Appendix A Introduction to SAS...............................................................................................................................69
Terminology Used in This Appendix ............................................................................................................69
What is SAS?.................................................................................................................................................69
How Do SAS Devices Communicate?...........................................................................................................69
What’s a Phy?...............................................................................................................................................70
5Proprietary and Condential to PMC-Sierra, Inc.
Document No.: CDP-00277-02-A Rev. A, Issue:
Serial Attached SCSI RAID Controllers Installation and User's Guide
剩余109页未读,继续阅读
资源评论
ekinrose
- 粉丝: 0
- 资源: 9
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功