力特 CT选型指导(英文).pdf

所需积分/C币:9 2019-10-24 03:32:35 2.59MB PDF
16
收藏 收藏
举报

力特 CT选型指导(英文)pdf,力特 CT选型指导(英文)
POWR-GARD@ Accessories Littelfuse Current Transformers, Ground Reference Modules Expertise Applied Answers Delivered PGC FAMILY PGG FAMILY CURRENT TRANSFORMERS Product Features Inner diamete Accessory For PGC-6035 35 mm Ground-Fault current Current transformer for measuring ground-fault currents (1.38") PGR-6150 Transformer PGC-6060 Current transformer for measuring 60 mm Ground-Fault current (236") PGR-6150 ound-fault currents Transformer PGC-6080 Ground-Fault Current Current transtormer for measuring 80 mm (3.15) PGR-6150 Transformer ground-tault currents PGC-6110 110mm Ground-Fault current Current transformer for measuring ground-fault currents 433) PGR-6150 Transformer PGC-6210 Ground-Fault Current Current transformer for measuring 210mm PGR-61-50 Transformer ground-fault currents (8.27") NOTE: Contact factory for 尽大正恒业电器有限公司 公网址 GROUND-REFERENCE MODULES Features pepo. C accessory PGG-0024 Ground reference Module 售捷线平)1 m∽∽ PGG-0048 Ground reference Connects the pgR-2601 relay to an ungrounded 48 Voc bus PGR-2601 Module PGG-0125 Ground reference Connects the PGR-2601 relay to an ungrounded 125 Vdc bus PGR-2601 Module PGG-0250 Ground reference Connects the PGR-2601 relay to an ungrounded 250 Vdc bus PGR-2601 Module PGG-0500 Ground Reference Connects the PGR-2601 relay to an ungrounded 500 Vdc bus PGR-2601 Module PGG-0780 Ground reference Connects the pGR-2601 relay to an ungrounded 780 Vdc bus PGR-2601 Module PGG-1000 Ground reference Connects the Pgr-2601 relay to an ungrounded 1000 Vdc bus PGR-2601 Module C 2010 Littelfuse. POWR-GARD Protection Relay Catalog 39 www.ittelfuse.cCm/protectionrelays Littelfuse POWR-GARD Accessories Panel Mount Adapter PGK FAMILY PANEL MOUNT ADAPTERS Product Features Accessory For PGK-0003 PGR-4704 Adapter Plate Used when replacing GEC/MCGG ground fault relays PGR-5701 PGK-0006 Used when replacing FPL-GFRM ground-fault relays R-5701 Adapter Plate PGK-0009 Used when replacing relays in the gE S1 Case PGR-6200 Adapter Plate PGR-7200 PGK-0010 Used when replacing the gE Lodtrak lll PGR-6200 Adapter Plate PGK-0012 Used when replacing GE and Westinghouse FT-11 relays PGR-6200 Adapter Plate PGK-0013 京 Used when replacing the GE Multilin 169, 269, or 369 PGR-6300 Adapter Plate Www. apepi com PGK-0014 Used for rough cutouts and when replacing the PGR-6300 ae Adapter Plate 010=5979011 PGK-0015 Used for rough cutouts and when replacing the PGR-6200 Adapter Plate GE Multilin P4a PGR-7200 PGK-0016 The PGK-0016 mounting plate is used when replacing the Adapter plate GE Multilin 169, 269, and 369 relays. The PGK-0016 RTDB PGR-6200 PGK-0016-RTDB is a mounting bracket for the optional PGA-0120 Temperature PGR-7200 Mounting Bracket Input Module PGK-0024 Used when replacing the GE Multilin 469 PGR-6300 Adapter Plate PGK-0055 PGR-2601 a. Used to panel mount the PGR-2601 and PGR-5701 PGR-5701 PGR-4300 Adapter Plate PGR-6200 PGR-4704 PGK-0060 PGR-2601 Used to panel mount the relay: IP 53 and NEMA 3 rating PGR-5701 PGR-4300 Adapter Plate tamper resistant PGR-6200 PGR-4704 PGA-016A PGR-6200 Watertight cover for outdoor applications Watertight cover PGR-7200 PGK-OSMK a kit to convert panel mounted relays to surface mounted PGR-6200 Converter Kit PGR-7200 Note: The relays shown in the table above are for illustrative purposes on'y and are not included with the PGK Family Pane/Mount Adapters ww.ittelfuse. com/protectionrelays C 2010 Littelfuse. POWR-GARD Protection Relay Catalog POWR-GARDO Accessories Littelfuse Input Modules, Remote Indication Expertise Applied Answers Delivered PGA FAMILY PGB FAMILY INPUT MODULES Product Features Accessory For PGA-0120 Provides 8 programmable inputs to connect Pt100, Ni100, Ni120 PGR-6200 Temperature and Cu10 RTD PGR-6300 Input Module PGA-0140 Adds motor differential protection, compatible with core balance PGR-6200 Differential and summation current transformer connections PGR-6300 Current module PGA-OCIM Interface between current transformers and pgr-6200 and PGR-6200 Current nput Module PGR-7200 series relays. Prevents open-CT hazards PGR-7200 北大工 REMOTE INDICATION Features 有限 Accessory For PGB-0302 Panel-mounted remote indication and reset. standard 22 mm Remote ndication 白白 mounting with NEMA 4 and NEMA 13 rating D CO PGM-8325 d Reset Assembly PGB-0325 nel-mounted remote indication and reset with 4790111 Remote ndication NEMA 1 rating PGM-8325 and reset assembly PGB-6130 Remote indication of overcurrent, phase imbalance Remote Indication phase loss, phase sequence, and overtemperature PGR-6130 and Reset assembly Remote reset included PGB-6800 Remote indication of overcurrent, undercurrent lemote Indication phase imbalance, phase loss, and phase sequence PGR-6800 and Reset assembly Remote reset included PGA-0500 PGR-2601 Panel-mounted analog meter displays ground-fault current PGR-5701 PGR-4300 Analog o current Meter as a percentage of the set-point PGR-6100 PGR-4704 PGA-0510 PGR-3200 Panel-mounted analog ohmmeter displays insulation resistance PGR-6100 Analog Ohm Meter from 0 Q2 to infinity PGR-8600 C 2010 Littelfuse. POWR-GARD Protection Relay Catalog www.ittelfuse.cCm/protectionrelays Littelfuse POWR-GARD Accessories Sensing Resistors, Terminations and Adapters PGE FAMILY PGH FAMILY. PGA FAMILY SENSING RESISTORS Product Features Accessory For PGE-600V PGR-5330 Used on systems up to 1 kV Sensing resistor PGM-8325 PGE-05KV PGR-5330 Used on systems up to 5 kV Sensing resistor PGM-8325 PGE-15KV PGR-5330 Sensing resistor Used on systems up to 15 kV PGM-8325 PGE-25KV Used on systems up to 25 kV PGR-5330 Sensing Resistor PGⅣM-8325 PGE-35KV Used on systems up to 35 kV Sensing resistor 电器有限 公可网 www.aneno.com TERMINATIONS AND ADAPTERS ae oduct e97911 Accessory For PGH-5000 PGR-3200 Allows 5-V systems to be connected to relay PGR-6100 High Tension Couplers PGR-8600 PGH-6000 PGR-3200 Allows 6-kv systems to be connected to relay PGR-6100 High Tension Couplers PGR-8600 PGA-OTA6 50 W ground-check termination with convenient mounting PGM-8134 termination Assembly holes and screw terminals, temperature compensated PGA-OTAZ 12 W ground-check termination, ideal for use in end caps Small-Format Termination and submersible pumps. Mounting holes and wire leads PGM-8134 Assembly with Wire Leads temperature compensated PGA-0400 PGR-6200 Port-Powered serial Converts an RS-485 signal to an RS-232 signal, used for PGR-6300 set-point programming and updating flash memory Converter PGR-7200 PGA-0420 Connects an RJ45 socket to a 9-pin serial connector, PGR-6200 Serial connector includes 1.5 m cable and plug-in adapter PGR-7200 Adapter Kit www.ittelfuse.com/protectionrelays C 2010 Littelfuse POWR- GARD Protection Relay Catalog

...展开详情
试读 6P 力特 CT选型指导(英文).pdf
立即下载
限时抽奖 低至0.43元/次
身份认证后 购VIP低至7折
一个资源只可评论一次,评论内容不能少于5个字
您会向同学/朋友/同事推荐我们的CSDN下载吗?
谢谢参与!您的真实评价是我们改进的动力~
  • 至尊王者

关注 私信
上传资源赚钱or赚积分
最新推荐
力特 CT选型指导(英文).pdf 9积分/C币 立即下载
1/6
力特 CT选型指导(英文).pdf第1页
力特 CT选型指导(英文).pdf第2页

试读结束, 可继续阅读

9积分/C币 立即下载