SigmaWin+5.75 Release Notes.pdf

所需积分/C币:20 2018-12-16 23:12:25 155KB PDF
收藏 收藏
举报

SigmaWin+5.75 Release Notes.pdf 安川伺服连机程序说明,老安川的,联机软件可以查找我的资源
19. Bug fix for Trace function for Sigma- 7 (1/0 could not be captured, description of settling time was wrong trace setting was wrong. <2-V-MD Components> 1. Added supported for SGDv-MDA01/MDB01 2. Bug fix for Sigma-5 MD function Some parameter was not displayed on previous version [Bug fix 1. Inertia ID function: When using SGME motor, lower limit of acceleration range is greater than higher limit 2. Connection via pcl doesn 't work 3. Pn515 parameter edit at sigma-5 large capacity doesnt work correctly SigmaWin+5.70a Release Notes 5/30/2014 Uninstall previous version before installing version 5. 70a Version 5.70a supports Windows7(32-bit and 64-bit Please reinstall the USB driver if you are upgrading from previous versions (5.53 or lower) then install new driver that is included with version 5.70a <Added specifications> Supported∑-7 s model and∑-7 W model(SGD7W20 and sgD7s-□00/10/20) For Sigma-7, this version does not support the Life monitor"function and the"Moment of inertia identification"function. Please use the moment of inertia calculation within Advanced Autotuning <Additional Function Improvement> Large capcity 2-V series(SGDV-[ 0 a U 11/21), is now able to connect via the MP controller SigmaWin +5.62 Release notes 1/9/2014 Uninstall previous version before installing version 5.62 Version 5.62 supports Windows7(32-bit and 64-bit Please reinstall the usb driver if you are upgrading from previous versions (5.53 or lower), then install new driver that is included with version 5.62 <Additional functions> Added support for Sigma-5 SGDV-MD Servopacks [Bug fix 1. Product in formation is not displayed correctly (Applicable version Ver5.60, Ver. 5.61) Page 3 of 7 2. In parameter setting display for Sigma-5 Device Net, Flash write button cannot be selected (Applicable version from Ver. 5.57 to Ver.5.61) 3. If using Sigma-5 large capacity ver.0029, default parameter for Pn515 is incorrect and written into other parameters as follows SGDV-xXXX01: Pn515 value is written into pn 50B SGDV-xXxX11 Pn515 value is written into pn50A (Applicable version: Ver. 5.60, Ver.5.61) 4. Connection via MP controller does not display 31st axis and 32nd axis if connecting 31 axis or more (Applicable version: Ver.5.61) 5. Mechatrolink communication reset cannot be performed if st# (Station number) and aDr Address number) is different (Applicable version: Ver.5.60, Ver.5.61) SigmaWin+5.61 Release Notes 9/9/2013 Uninstall previous version before installing version 5.61 Version 5.61 supports Windows 32-bit and 64-bit) Please reinstall the USB driver if you are upgrading from previous versions(5.53 or lower) <Additional functions> (1) Support sigma-5 Option card combination as follows K+3 4‖oK K Fully-chsec+ OK+ 0<+ Ok|okp )K-OK (2)Added support of the data base for Feedback option module (SGDv-OFBO1A, OFB03A, OFB04A) These features are enabled when the fb option module is mounted in Servopack with firmware version 0029 or higher 3)Added support for Servopack firmware version 0029 (4)Added support Buffer strategies for the interpolated position mode"for Ethre CAT(coe)module (5)Added support of the parameters and l/o signals for Sigma-5 large capacity(M3/Command) (6)Upgraded the database for safety option module Bug Fix 1)Corrected display of l/0 signals for deviceNet option module 2)Corrected the issue that sigmawin+ may not run via controller connection 3) Corrected the issue when the parameter edit is started by the combination with Ether cat option module(ver3 or less abnormal data may be generated Page 4 of 7 SigmaWin+5.58 Release notes 6/4/2013 Uninstall previous version before installing version 5.58 Version 5.58 supports Windows7(32-bit and 64-bit Please reinstall the usb driver if you are upgrading from previous versions 5.53 or lower) <Additional functions> (1)Added support for 200V Sigma-5 large capacity Servopacks (2) Added support for DC input Sigma-5 Servopacks ()Added support to connect MP controller without using MPE720 (4)Added support for new Sigma-5 Servopack parameters: Support Sigma-5 large capacity parameters Pn515, Pn601; and Sigma-5 mini parameters Pn550-Pn553 Pn20D(4bytes parameter ) was corrected to connect servo by using a controller via communication manager SigmaWin+5.57 Release Notes 3/7/2013 Uninstall previous version before installing version 5.57 Version 5.57 supports Windows7 32-bit and 64-bit) Please reinstall the usB driver if you are upgrading from previous versions (5.53 or lower) <Additional functions> (1) Added support for Sigma-5 DeviceNet (SGDv-OCA04A, SGDV-OCAO5A) SigmaWin +5.56a Release Notes 1/9/2013 Uninstall previous version before installing version 5.56a Version 5.56a supports Windows7(32-bit and 64-bit Please reinstall the usb driver if you are upgrading from previous versions 5.53 or lower) <Additional functions> (1)Added support for Sigma-5 400v large capacity Servopacks (2)Added support for Sigma-5 MECHATROLINK-I DC power input (SGDV-**K E11) Servopacks through the controller via MP-in Units with Svb built-in(CPU: higher than Ver 2.81, SvB-01: Ver 1. 30 or higher) (3)Added support for Vero028 Sigma-5 Servopacks (4)Added support for Sigma-5 MECHATROLINK-ll servo(sGDv-** *k* 21/25)+ safety option module combination (5)In the Trace function added"Estimated disturbance torque Page 5 of 7 fixes (1)In version 5.55, when using the Setup Wizard, if the combination of Sigma-5 com mand-option type Servopack(SGDv-****E1/E5)+ Sigma-5 INDEXER (SGDV-OCA03Aoption module is selected, the wizard cannot proceed and the following message is displayed Setup wead fReak salih sating tEth SGEV-ET00NTp EnGe时retn E senvepack selection / a Encoder selection Eneaat seect4i2p-b rements semvorackand modee electon Confirm your modw model and servepsckedde h Deine mode IFuly-cioned sendar: Do nottle whea hd Ciry钟enee, the madris are audem感出 Mayed b oif me(whn JA Eonb'oleds sedco Control Mode selection Petersen Could not find the designated parameter D in the PRMNFO. Sr Uptar Enoder Betn a eneoder type, indef ut setme rtor sinommetc arewtettergrnettu setle g occurence wf asm when me sars 品5量 dnd seed d!( nator power is br or the a想n办vd(mm已5已ed 4vO Signal Setting Th s的 maers sf the Cii esenegeer ean动9 心55m am物时n到说的翻pvt四wmmg a3M成g check the alocated ssni and same the paramera tie This is corrected in version 5. 56a (2) Fixed the value for cn-0 F of gdf-□匚口 P Servopack SigmaWin+5.55 Release Notes 4/13/2012 Version 5.55 supports Windows 7 64-bit Please reinstall the usb driver if you are upgrading from previous versions 5.53 or lower) <Additional function> 1)MP controller MP3200 support added. (MPE720 Ver 7. 11 or higher) 2)MP controller to sigma-5 mini ( SGDv-21 support added. MPE720 Ver 7. 11 or higher or MPE720 Ver 6.23 or higher) 3)Sigma-5 INDEXER Vero004 PnB53 is added Page 6 of 7 SigmaWin+5.54 Release Notes 10/18/2011 Version 5.54 supports Windows7 64-bit Please reinstall the usb driver with the one supplied with SigmaWin +5. 54 if you are upgrading from previous versions <Additional function> 1)Support for dC power input Sigma-5 series(SGDv-11/21/P1/ S1)added SigmaWin +5.53 Release Notes 7/28/2011 Version 5.53 supports Windows7 32-bit only Please reinstall the UsB driver with the one supplied with SigmaWin+5.53 if you are upgrading from previous versions <Additional function> 1) Improved compatibility for the servo amplifier firmware Ver.0023 or higher: s The parameter and monitor are added for fanless servo (environment Monitor), backlash offset function, and homing speed range <Bug FiX> 1) Parameter download failure popup comes up even if parameter was downloaded successfully when using motor parameter download function for linear scale 2)Pn552 and 553 (Analog monitor output voltage gains) gets wrong setting when useing parameter conversion function to convert Sigma-2 parameter for Sigma-5 parameter. If Pn003 bit O or 1 is set as 0, 1, 5, 6 or 7 on the Sigma-2, this problem will occur. Page 7 of 7

...展开详情
试读 7P SigmaWin+5.75 Release Notes.pdf
立即下载 低至0.43元/次 身份认证VIP会员低至7折
    一个资源只可评论一次,评论内容不能少于5个字
    qq_32146753 骗积分的!!!!
    2019-10-30
    回复
    • 签到新秀

      累计签到获取,不积跬步,无以至千里,继续坚持!
    • 分享王者

      成功上传51个资源即可获取
    关注 私信 TA的资源
    上传资源赚积分,得勋章
    最新推荐
    SigmaWin+5.75 Release Notes.pdf 20积分/C币 立即下载
    1/7
    SigmaWin+5.75 Release Notes.pdf第1页
    SigmaWin+5.75 Release Notes.pdf第2页
    SigmaWin+5.75 Release Notes.pdf第3页

    试读已结束,剩余4页未读...

    20积分/C币 立即下载 >