Technical Product Information
Y 258 E00 015e
Seite/Page 3 von/of 13
Datum/Date 14.6.2005
©Alle Rechte bei Robert Bosch GmbH, auch für den Fall von Schutzrechtsanmeldungen. Jede Verfügungsbefugnis, wie Kopier- und Weitergaberecht, bei uns.
©Robert Bosch GmbH reserves all rights even in the event of industrial property.We reserve all rights of disposal such as copying and passing on to third parties
1.3 Sensor element
The heater supply voltage must be controlled, so that the temperature of
the sensor is kept at the operation point. The temperature is measured by
measuring the internal resistance of the sensor’s Nernst cell R
i,N
Nominal internal resistance of λ=1 Nernst cell R
i,N
for new sensors (operating and calibration point)
(measured with AC f = 1...4 kHz) 300 Ω
Max. current load of λ=1 Nernst cell
Continuous AC (f = 1...4 kHz) ≤ 250 µA
for R
I,N
measurement
Recommended value for reference pumping current
continuous = 20 µA
Max. pumping current into pump cell (I
p
)
- for rich gas signal (λ≥0,65) ≥ -9 mA
- for lean gas signal (air) ≤ 6 mA
1.4 Isolation resistance
(all values for new sensors in static air, heater off)
- between housing and each heater- and
sensor circuit connector pin at room
temperature ≥ 30 MΩ
- between sensor signal circuit and heater
circuit at 600°C hexagon temperature ≥ 1 MΩ
- between sensor signal pin APE and housing
at 600°C hexagon temperature: ≥ 100 kΩ