Modbus Poll V3.60a
Copyright (c) Witte Communications 2004. All rights reserved.
------------------------------------------------------------------------------------
IMPORTANT for win95 users:
-----------------------------
If the file ws2_32.dll is not found you have to
update your win95 with the service pack w95ws2setup.exe.
Download it from www.modbustools.com or www.microsoft.com
New features in version 3.60a
-----------------------------
- Text for TCP/IP Timeout information corrected.
- 4 minutes trial period extended to 10 minutes.
New features in version 3.6
-----------------------------
- TCP/IP Display communication improved.
- 'Remove Echo' check box in connection setup added.
- Minor changes in help file.
- Connection information in status bar.
- Error Counters in display menu. (F11)
New features in version 3.5
-----------------------------
- Open/save workspace. File menu
- Always on top. View menu.
- Scan rate now up to 60000ms
- "Stop on error" in traffic view
- Modbus Transaction ID in TCP/IP is now unique
- The logging function logs errors as well
- Timing bug when logging multiple windows is fixed
Modbus Poll overview
-----------------------------
Modbus Poll is a powerful, easy to use, Modbus tool.
With Modbus Poll you can monitor and test your modbus
slave devices. Some of the features:
- Supports Modbus/TCP, RTU and ASCII modes.
- Test Center for modbus slave developers.
- OLE Automation for interfacing with Visual Basic
Excel etc. To interpret and show the modbus data
according to your specific requirements. E.g. edit
data in Excel and then send to your slave!
- Multiple windows for monitoring of multiple
slaves/data areas.
- Monitoring of serial traffic.
- Data logging to a text file readable by MS Excel.
- Multithreated for best performance.
- Print preview etc.
- 10 Display formats.
To change a value, simply double click.
System Requirements
-----------------------------
Minimal configuration:
* Pentium 133 or higher
* 32MB RAM
* 800x600 screen resolution
* Windows 95/98/ME/NT4/2000/XP
Preferred configuration:
* Pentium 200 or higher
* 32MB RAM
* 800x600 screen resolution
* Windows 95/98/ME/NT4/2000/XP
Order information
-----------------------------
Visit http://www.modbustools.com
Technical Support
Your feedback is very important for the further development
of Modbus Poll. For bug reports, comments, suggestions or
complaints, please find contact information at
http://www.modbustools.com