没有合适的资源?快使用搜索试试~ 我知道了~
HP 磁盘阵列 P800安装指南
需积分: 10 8 下载量 196 浏览量
2009-08-11
14:31:46
上传
评论
收藏 632KB PDF 举报
温馨提示
试读
2页
HP 磁盘阵列 P800安装指南,惠普服务器系列阵列卡。详细使用说明,供大家分享参考安装
资源推荐
资源详情
资源评论
Kit contents
All controller kits contain an installation overview poster (this
document), a Documentation CD, and a controller board.
Each controller kit also contains one of the following software
CD kits:
• SmartStart CD kit (contains device drivers, support software
and utilities, HP Insight Diagnostics, Management Agents,
and documentation for SmartStart and HP Systems
Insight Manager)
• Support Software CD kit (contains device drivers
and utilities)
The SmartStart CD does not provide support for HP Integrity
servers. In this case, use the Smart Setup media instead.
Installing the controller in an
unconfi gured HP ProLiant server
New HP ProLiant server models autoconfi gure when they
are powered up for the fi rst time. For more information
about the autoconfi guration process, see the server-specifi c
setup and installation guide or the HP ROM-Based Setup
Utility User Guide. These guides are available on the server
Documentation CD.
IMPORTANT: Do not power up the server until the
hardware confi guration is satisfactory, as described in
the procedure given in this section.
To install the controller in an unconfi gured server:
1. Install the controller hardware.
2. If necessary, install physical drives.
The number of drives connected to the controller determines
the RAID level that is autoconfi gured when the server is
powered up. For details, see the server-specifi c setup and
installation guide or the HP ROM-Based Setup Utility
User Guide.
3. Power up the server. The autoconfi guration process runs.
4. Update the server fi rmware.
5. Update the controller fi rmware.
6. Install the operating system and device drivers. Instructions
are provided with the CD that is supplied in the
controller kit.
7. (Optional) Create additional logical drives.
The server is now ready to use.
Installing the controller in a
confi gured HP ProLiant server
1. Back up data on the system.
2. Update the server fi rmware.
3. If the new controller will be the boot device, install the
device drivers. Otherwise, go directly to step 4.
4. Power down the server.
HP Smart Array P800
Controller
Installation Overview
Second Edition (January 2007)
Part Number 432601-002
Les "Viktig sikkerhetsinformasjon" på dokumentasjons-CDen før du installerer dette produktet.
Læs dokumentet Vigtige sikkerhedsoplysninger på dokumentations-cd'en, før produktet installeres.
Prima dell'installazione, leggere sul CD le Informazioni importanti sulla sicurezza.
Tärkeisiin turvatietoihin" Documentation CD -levyllä ennen tuotteen asentamista.
Läs dokumentet Viktig säkerhetsinformation på dokumentations-cd:n innan du installerar denna produkt.
Important Safety Information
资源评论
alextnt
- 粉丝: 0
- 资源: 1
上传资源 快速赚钱
- 我的内容管理 展开
- 我的资源 快来上传第一个资源
- 我的收益 登录查看自己的收益
- 我的积分 登录查看自己的积分
- 我的C币 登录后查看C币余额
- 我的收藏
- 我的下载
- 下载帮助
最新资源
- 高等数学第一章第二节数列的极限
- Python 版冒泡排序算法源代码
- tensorflow-gpu-2.7.2-cp38-cp38-manylinux2010-x86-64.whl
- tensorflow-2.7.3-cp39-cp39-manylinux2010-x86-64.whl
- tensorflow-2.7.2-cp39-cp39-manylinux2010-x86-64.whl
- Python版本快速排序源代码
- Python 语言版的快速排序算法实现
- 450815388207377安卓_base.apk
- 超微主板 X9DRE-TF+ bios 支持 nvme启动
- 基于Python通过下载气象数据和插值拟合离散数据曲线实现对寒潮过程的能量分析
资源上传下载、课程学习等过程中有任何疑问或建议,欢迎提出宝贵意见哦~我们会及时处理!
点击此处反馈
安全验证
文档复制为VIP权益,开通VIP直接复制
信息提交成功